| Package | hl7.fhir.eu.imaging-manifest-r5 |
| Resource Type | StructureDefinition |
| Id | EHDSDeviceUse |
| FHIR Version | R5 |
| Source | http://hl7.eu/fhir/imaging-manifest-r5/https://build.fhir.org/ig/hl7-eu/imaging-manifest/StructureDefinition-EHDSDeviceUse.html |
| URL | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDeviceUse |
| Version | 0.1.0 |
| Status | draft |
| Date | 2025-03-21T08:17:12+00:00 |
| Name | EHDSDeviceUse |
| Title | Device use model |
| Realm | eu |
| Authority | hl7 |
| Description | C.25 - EHDS refined base model for Device Use |
| Copyright | Used by permission of HL7 Europe, all rights reserved Creative Commons License |
| Type | https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDeviceUse |
| Kind | logical |
| StructureDefinition | |
| EHDSPatientSummaryBody | Patient summary body model |
| EHDSDischargeReport | Discharge Report model |
| StructureDefinition | |
| EHDSDevice | Device model |
| EHDSHealthProfessional | Health professional model |
| EHDSPatient | Patient model |
| EHDSRelatedPerson | Related person model |
Note: links and images are rebased to the (stated) source
Generated Narrative: StructureDefinition EHDSDeviceUse
| Name | Flags | Card. | Type | Description & Constraints |
|---|---|---|---|---|
![]() | 0..* | Base | Device use model Instances of this logical model can be the target of a Reference | |
![]() ![]() | 0..* | Identifier | C.25.1 - Identifier | |
![]() ![]() | 0..1 | CodeableConcept | C.25.2 - Status Binding Description: (preferred): HL7 device-statement-status | |
![]() ![]() | 0..1 | dateTime | C.25.3 - Implant date | |
![]() ![]() | 0..1 | dateTime | C.25.4 - End date | |
![]() ![]() | 1..1 | Reference(Device model) | C.25.5 - Device | |
![]() ![]() | 1..1 | Reference(Patient model) | C.25.6 - Subject | |
![]() ![]() | 0..1 | CodeableConcept | C.25.7 - Body site | |
![]() ![]() | 0..* | Narrative | C.25.8 - Note This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |
![]() ![]() | 0..1 | dateTime | C.25.9 - Recorded | |
![]() ![]() | 0..1 | Reference(Patient model | Health professional model | Related person model) | C.25.10 - Source | |
{
"resourceType": "StructureDefinition",
"id": "EHDSDeviceUse",
"text": {
"status": "extensions",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-type-characteristics",
"valueCode": "can-be-target"
}
],
"url": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDeviceUse",
"version": "0.1.0",
"name": "EHDSDeviceUse",
"title": "Device use model",
"status": "draft",
"date": "2025-03-21T08:17:12+00:00",
"publisher": "HL7 Europe",
"contact": [
{
"name": "Xt-EHR",
"telecom": [
{
"system": "url",
"value": "http://Xt-EHR.eu"
}
]
}
],
"description": "C.25 - EHDS refined base model for Device Use",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "150",
"display": "Europe"
}
]
}
],
"copyright": "Used by permission of HL7 Europe, all rights reserved Creative Commons License",
"fhirVersion": "5.0.0",
"mapping": [
{
"identity": "rim",
"uri": "http://hl7.org/v3",
"name": "RIM Mapping"
}
],
"kind": "logical",
"abstract": false,
"type": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDeviceUse",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Base",
"derivation": "specialization",
"snapshot": {
"extension": [
{
"url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
"valueString": "5.0.0"
}
],
"element": [
{
"id": "EHDSDeviceUse",
"path": "EHDSDeviceUse",
"short": "Device use model",
"definition": "C.25 - EHDS refined base model for Device Use",
"min": 0,
"max": "*",
"base": {
"path": "Base",
"min": 0,
"max": "*"
},
"isModifier": false,
"mapping": [
{
"identity": "rim",
"map": "n/a"
}
]
},
{
"id": "EHDSDeviceUse.identifier",
"path": "EHDSDeviceUse.identifier",
"short": "C.25.1 - Identifier",
"definition": "An identifier for this statement.",
"min": 0,
"max": "*",
"base": {
"path": "EHDSDeviceUse.identifier",
"min": 0,
"max": "*"
},
"type": [
{
"code": "Identifier"
}
]
},
{
"id": "EHDSDeviceUse.status",
"path": "EHDSDeviceUse.status",
"short": "C.25.2 - Status",
"definition": "Current status of the Device Usage.",
"min": 0,
"max": "1",
"base": {
"path": "EHDSDeviceUse.status",
"min": 0,
"max": "1"
},
"type": [
{
"code": "CodeableConcept"
}
],
"binding": {
"strength": "preferred",
"description": "HL7 device-statement-status"
}
},
{
"id": "EHDSDeviceUse.implantDate",
"path": "EHDSDeviceUse.implantDate",
"short": "C.25.3 - Implant date",
"definition": "Date when procedure was performed.",
"min": 0,
"max": "1",
"base": {
"path": "EHDSDeviceUse.implantDate",
"min": 0,
"max": "1"
},
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "EHDSDeviceUse.endDate",
"path": "EHDSDeviceUse.endDate",
"short": "C.25.4 - End date",
"definition": "Date when the device was explanted from the patient or the external device was no longer in use; likewise when the device is planned to be explanted.",
"min": 0,
"max": "1",
"base": {
"path": "EHDSDeviceUse.endDate",
"min": 0,
"max": "1"
},
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "EHDSDeviceUse.device",
"path": "EHDSDeviceUse.device",
"short": "C.25.5 - Device",
"definition": "The details of the device used.",
"min": 1,
"max": "1",
"base": {
"path": "EHDSDeviceUse.device",
"min": 1,
"max": "1"
},
"type": [
{
"code": "Reference",
"targetProfile": [
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice"
]
}
]
},
{
"id": "EHDSDeviceUse.subject",
"path": "EHDSDeviceUse.subject",
"short": "C.25.6 - Subject",
"definition": "The patient using the device.",
"min": 1,
"max": "1",
"base": {
"path": "EHDSDeviceUse.subject",
"min": 1,
"max": "1"
},
"type": [
{
"code": "Reference",
"targetProfile": [
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSPatient"
]
}
]
},
{
"id": "EHDSDeviceUse.bodySite",
"path": "EHDSDeviceUse.bodySite",
"short": "C.25.7 - Body site",
"definition": "Anatomical location of the device. May include laterality.",
"min": 0,
"max": "1",
"base": {
"path": "EHDSDeviceUse.bodySite",
"min": 0,
"max": "1"
},
"type": [
{
"code": "CodeableConcept"
}
]
},
{
"id": "EHDSDeviceUse.note",
"path": "EHDSDeviceUse.note",
"short": "C.25.8 - Note",
"definition": "Details about the device statement that were not represented at all or sufficiently in one of the attributes provided in a class. These may include for example a comment, an instruction, or a note associated with the statement.",
"min": 0,
"max": "*",
"base": {
"path": "EHDSDeviceUse.note",
"min": 0,
"max": "*"
},
"type": [
{
"code": "Narrative"
}
]
},
{
"id": "EHDSDeviceUse.recorded",
"path": "EHDSDeviceUse.recorded",
"short": "C.25.9 - Recorded",
"definition": "Date and time at which the statement was made/recorded.",
"min": 0,
"max": "1",
"base": {
"path": "EHDSDeviceUse.recorded",
"min": 0,
"max": "1"
},
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "EHDSDeviceUse.source",
"path": "EHDSDeviceUse.source",
"short": "C.25.10 - Source",
"definition": "Who reported the device was being used by the patient.",
"min": 0,
"max": "1",
"base": {
"path": "EHDSDeviceUse.source",
"min": 0,
"max": "1"
},
"type": [
{
"code": "Reference",
"targetProfile": [
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSPatient",
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional",
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSRelatedPerson"
]
}
]
}
]
},
"differential": {
"element": [
{
"id": "EHDSDeviceUse",
"path": "EHDSDeviceUse",
"short": "Device use model",
"definition": "C.25 - EHDS refined base model for Device Use"
},
{
"id": "EHDSDeviceUse.identifier",
"path": "EHDSDeviceUse.identifier",
"short": "C.25.1 - Identifier",
"definition": "An identifier for this statement.",
"min": 0,
"max": "*",
"type": [
{
"code": "Identifier"
}
]
},
{
"id": "EHDSDeviceUse.status",
"path": "EHDSDeviceUse.status",
"short": "C.25.2 - Status",
"definition": "Current status of the Device Usage.",
"min": 0,
"max": "1",
"type": [
{
"code": "CodeableConcept"
}
],
"binding": {
"strength": "preferred",
"description": "HL7 device-statement-status"
}
},
{
"id": "EHDSDeviceUse.implantDate",
"path": "EHDSDeviceUse.implantDate",
"short": "C.25.3 - Implant date",
"definition": "Date when procedure was performed.",
"min": 0,
"max": "1",
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "EHDSDeviceUse.endDate",
"path": "EHDSDeviceUse.endDate",
"short": "C.25.4 - End date",
"definition": "Date when the device was explanted from the patient or the external device was no longer in use; likewise when the device is planned to be explanted.",
"min": 0,
"max": "1",
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "EHDSDeviceUse.device",
"path": "EHDSDeviceUse.device",
"short": "C.25.5 - Device",
"definition": "The details of the device used.",
"min": 1,
"max": "1",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice"
]
}
]
},
{
"id": "EHDSDeviceUse.subject",
"path": "EHDSDeviceUse.subject",
"short": "C.25.6 - Subject",
"definition": "The patient using the device.",
"min": 1,
"max": "1",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSPatient"
]
}
]
},
{
"id": "EHDSDeviceUse.bodySite",
"path": "EHDSDeviceUse.bodySite",
"short": "C.25.7 - Body site",
"definition": "Anatomical location of the device. May include laterality.",
"min": 0,
"max": "1",
"type": [
{
"code": "CodeableConcept"
}
]
},
{
"id": "EHDSDeviceUse.note",
"path": "EHDSDeviceUse.note",
"short": "C.25.8 - Note",
"definition": "Details about the device statement that were not represented at all or sufficiently in one of the attributes provided in a class. These may include for example a comment, an instruction, or a note associated with the statement.",
"min": 0,
"max": "*",
"type": [
{
"code": "Narrative"
}
]
},
{
"id": "EHDSDeviceUse.recorded",
"path": "EHDSDeviceUse.recorded",
"short": "C.25.9 - Recorded",
"definition": "Date and time at which the statement was made/recorded.",
"min": 0,
"max": "1",
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "EHDSDeviceUse.source",
"path": "EHDSDeviceUse.source",
"short": "C.25.10 - Source",
"definition": "Who reported the device was being used by the patient.",
"min": 0,
"max": "1",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSPatient",
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional",
"https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSRelatedPerson"
]
}
]
}
]
}
}