FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/LabOrderDataElementsCz

Packagehl7.fhir.cz.lab-order
TypeStructureDefinition
IdLabOrderDataElementsCz
FHIR VersionR4
Sourcehttps://hl7.cz/fhir/lab-order/https://build.fhir.org/ig/HL7-cz/lab-order/StructureDefinition-LabOrderDataElementsCz.html
URLhttps://hl7.cz/fhir/lab-order/StructureDefinition/LabOrderDataElementsCz
Version0.0.1
Statusdraft
Date2025-07-18T09:02:08+00:00
NameLabOrderDataElementsCz
TitleA.2.8 - Laboratory order data elements
Realmcz
Authorityhl7
DescriptionLaboratory order data elements
Typehttps://hl7.cz/fhir/lab-order/StructureDefinition/LabOrderDataElementsCz
Kindlogical

Resources that use this resource

StructureDefinition
LabOrderBodyA.2 Laboratory Order body data elements

Resources that this resource uses

StructureDefinition
ClinicalEventA.2.3 - Clinical event (Encounter)

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: StructureDefinition LabOrderDataElementsCz

NameFlagsCard.TypeDescription & Constraintsdoco
.. LabOrderDataElementsCz 0..*BaseA.2.8 - Laboratory order data elements
... examination 0..*BackboneElementA.2.8.1 - Required examinations
.... code 1..1CodeableConceptA.2.8.1.1 - Examination code
.... name 1..1CodeableConceptA.2.8.1.2 - Name of examination
.... procedure 0..1CodeableConceptA.2.8.1.3 - Examination procedure
.... accreditation 0..1CodeableConceptA.2.8.1.4 - Accreditation
.... urgency 0..1CodeableConceptA.2.8.1.5 - Urgency
.... note 0..1stringA.2.8.1.6 - Note
.... clinicalEvent 0..1ClinicalEventA.2.8.1.7 - Clinical event (encounter)

doco Documentation for this format

Source

{
  "resourceType": "StructureDefinition",
  "id": "LabOrderDataElementsCz",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 1
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "draft"
    }
  ],
  "url": "https://hl7.cz/fhir/lab-order/StructureDefinition/LabOrderDataElementsCz",
  "version": "0.0.1",
  "name": "LabOrderDataElementsCz",
  "title": "A.2.8 - Laboratory order data elements",
  "status": "draft",
  "date": "2025-07-18T09:02:08+00:00",
  "publisher": "HL7 Czech Republic",
  "contact": [
    {
      "name": "HL7 Czech Republic",
      "telecom": [
        {
          "system": "url",
          "value": "https://www.hl7.cz/"
        }
      ]
    }
  ],
  "description": "Laboratory order data elements",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "urn:iso:std:iso:3166",
          "code": "CZ",
          "display": "Czechia"
        }
      ]
    }
  ],
  "fhirVersion": "4.0.1",
  "kind": "logical",
  "abstract": false,
  "type": "https://hl7.cz/fhir/lab-order/StructureDefinition/LabOrderDataElementsCz",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Base",
  "derivation": "specialization",
  "snapshot": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
        "valueString": "4.0.1"
      }
    ],
    "element": [
      {
        "id": "LabOrderDataElementsCz",
        "path": "LabOrderDataElementsCz",
        "short": "A.2.8 - Laboratory order data elements",
        "definition": "Laboratory order data elements",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Base",
          "min": 0,
          "max": "*"
        },
        "isModifier": false
      },
      {
        "id": "LabOrderDataElementsCz.examination",
        "path": "LabOrderDataElementsCz.examination",
        "short": "A.2.8.1 - Required examinations",
        "definition": "A.2.8.1 - Required examinations",
        "min": 0,
        "max": "*",
        "base": {
          "path": "LabOrderDataElementsCz.examination",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "BackboneElement"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.id",
        "path": "LabOrderDataElementsCz.examination.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "Unique id for inter-element referencing",
        "definition": "Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fhir-type",
                "valueUrl": "string"
              }
            ],
            "code": "http://hl7.org/fhirpath/System.String"
          }
        ],
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.extension",
        "path": "LabOrderDataElementsCz.examination.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), \"value\")])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.modifierExtension",
        "path": "LabOrderDataElementsCz.examination.modifierExtension",
        "short": "Extensions that cannot be ignored even if unrecognized",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.\n\nModifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "requirements": "Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored.  This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).",
        "alias": [
          "extensions",
          "user content",
          "modifiers"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "BackboneElement.modifierExtension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), \"value\")])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": true,
        "isModifierReason": "Modifier extensions are expected to modify the meaning or interpretation of the element that contains them",
        "isSummary": true,
        "mapping": [
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.code",
        "path": "LabOrderDataElementsCz.examination.code",
        "short": "A.2.8.1.1 - Examination code",
        "definition": "A code representing an examination within an agreed codebook.\n- Preffered system(s): NČLP",
        "min": 1,
        "max": "1",
        "base": {
          "path": "LabOrderDataElementsCz.examination.code",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.name",
        "path": "LabOrderDataElementsCz.examination.name",
        "short": "A.2.8.1.2 - Name of examination",
        "definition": "Full name of the examination according to the codebook used.\n- Preffered system(s): NČLP",
        "min": 1,
        "max": "1",
        "base": {
          "path": "LabOrderDataElementsCz.examination.name",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.procedure",
        "path": "LabOrderDataElementsCz.examination.procedure",
        "short": "A.2.8.1.3 - Examination procedure",
        "definition": "Required examination procedure (measurement principle).\n- Preffered system(s): SNOMED CT\n- Preffered system(s): NČLP - NCLPPROC",
        "min": 0,
        "max": "1",
        "base": {
          "path": "LabOrderDataElementsCz.examination.procedure",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.accreditation",
        "path": "LabOrderDataElementsCz.examination.accreditation",
        "short": "A.2.8.1.4 - Accreditation",
        "definition": "Requirement that only laboratories accredited for the test be able to perform the test.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "LabOrderDataElementsCz.examination.accreditation",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.urgency",
        "path": "LabOrderDataElementsCz.examination.urgency",
        "short": "A.2.8.1.5 - Urgency",
        "definition": "The urgency of the requested examination (vital indication, statim, priority (fast track), routine) if different from the urgency of the entire order.\n- Preffered system(s): HL7:RequestPriority\n- Preffered system(s): LOUP",
        "min": 0,
        "max": "1",
        "base": {
          "path": "LabOrderDataElementsCz.examination.urgency",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.note",
        "path": "LabOrderDataElementsCz.examination.note",
        "short": "A.2.8.1.6 - Note",
        "definition": "Client's note on the requested examination",
        "min": 0,
        "max": "1",
        "base": {
          "path": "LabOrderDataElementsCz.examination.note",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.clinicalEvent",
        "path": "LabOrderDataElementsCz.examination.clinicalEvent",
        "short": "A.2.8.1.7 - Clinical event (encounter)",
        "definition": "Information about the clinical event to which the ordered examination relates",
        "min": 0,
        "max": "1",
        "base": {
          "path": "LabOrderDataElementsCz.examination.clinicalEvent",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "https://hl7.cz/fhir/lab-order/StructureDefinition/ClinicalEvent"
          }
        ]
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "LabOrderDataElementsCz",
        "path": "LabOrderDataElementsCz",
        "short": "A.2.8 - Laboratory order data elements",
        "definition": "Laboratory order data elements"
      },
      {
        "id": "LabOrderDataElementsCz.examination",
        "path": "LabOrderDataElementsCz.examination",
        "short": "A.2.8.1 - Required examinations",
        "definition": "A.2.8.1 - Required examinations",
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "BackboneElement"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.code",
        "path": "LabOrderDataElementsCz.examination.code",
        "short": "A.2.8.1.1 - Examination code",
        "definition": "A code representing an examination within an agreed codebook.\n- Preffered system(s): NČLP",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.name",
        "path": "LabOrderDataElementsCz.examination.name",
        "short": "A.2.8.1.2 - Name of examination",
        "definition": "Full name of the examination according to the codebook used.\n- Preffered system(s): NČLP",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.procedure",
        "path": "LabOrderDataElementsCz.examination.procedure",
        "short": "A.2.8.1.3 - Examination procedure",
        "definition": "Required examination procedure (measurement principle).\n- Preffered system(s): SNOMED CT\n- Preffered system(s): NČLP - NCLPPROC",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.accreditation",
        "path": "LabOrderDataElementsCz.examination.accreditation",
        "short": "A.2.8.1.4 - Accreditation",
        "definition": "Requirement that only laboratories accredited for the test be able to perform the test.",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.urgency",
        "path": "LabOrderDataElementsCz.examination.urgency",
        "short": "A.2.8.1.5 - Urgency",
        "definition": "The urgency of the requested examination (vital indication, statim, priority (fast track), routine) if different from the urgency of the entire order.\n- Preffered system(s): HL7:RequestPriority\n- Preffered system(s): LOUP",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.note",
        "path": "LabOrderDataElementsCz.examination.note",
        "short": "A.2.8.1.6 - Note",
        "definition": "Client's note on the requested examination",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "LabOrderDataElementsCz.examination.clinicalEvent",
        "path": "LabOrderDataElementsCz.examination.clinicalEvent",
        "short": "A.2.8.1.7 - Clinical event (encounter)",
        "definition": "Information about the clinical event to which the ordered examination relates",
        "min": 0,
        "max": "1",
        "type": [
          {