Package | hl7.ehrs.uv.phrsfmr2 |
Type | Requirements |
Id | PHRSFMR2-S.2.3 |
FHIR Version | R5 |
Source | http://hl7.org/ehrs/uv/phrsfmr2/https://build.fhir.org/ig/HL7/phrsfm-ig/Requirements-PHRSFMR2-S.2.3.html |
URL | http://hl7.org/ehrs/uv/phrsfmr2/Requirements/PHRSFMR2-S.2.3 |
Version | 2.0.1-ballot |
Status | active |
Date | 2025-04-03T15:15:30+00:00 |
Name | S_2_3_Manage_Standard_Reporting |
Title | S.2.3 Manage Standard Reporting (Function) |
Authority | hl7 |
Description | Enable PHR Account Holders or authorized designees to request and read pre-configured, packaged reports of PHR information. |
Purpose | PHR Account Holders may request standard, pre-configured, packaged reports. The purpose is not for PHR interchange but rather for PHR Account Holder’s analysis of his/her health related financial and administrative data, and for sharing (if desired). |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Enable PHR Account Holders or authorized designees to request and read pre-configured, packaged reports of PHR information.
PHR Account Holders may request standard, pre-configured, packaged reports. The purpose is not for PHR interchange but rather for PHR Account Holder’s analysis of his/her health related financial and administrative data, and for sharing (if desired).
S.2.3#01 | SHOULD |
The system SHOULD provide the ability to render standard reports of structured clinical and administrative and financial data using either internal or external reporting tools. |
S.2.3#02 | SHOULD |
The system SHOULD provide the ability to maintain report parameters based on data sorted or filtered by the PHR Account Holder or by the PHR-S settings. |
S.2.3#03 | MAY |
The system MAY provide the ability to render information from unstructured clinical and administrative data in the report generation process using internal or external tools. |
S.2.3#04 | MAY |
The system (or an external application using data from the PHR-S) MAY provide the ability to maintain report parameters for generating subsequent reports. |
S.2.3#05 | MAY |
The system (or an external application using data from the PHR-S) MAY provide the ability to update one or more parameters of a saved report specification when generating a report using that specification. |
{ "resourceType": "Requirements", "id": "PHRSFMR2-S.2.3", "meta": { "profile": [ "http://hl7.org/ehrs/uv/phrsfmr2/StructureDefinition/FMFunction" ] }, "text": { "status": "extensions", "div": "<!-- snip (see above) -->" }, "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "ehr" } ], "url": "http://hl7.org/ehrs/uv/phrsfmr2/Requirements/PHRSFMR2-S.2.3", "version": "2.0.1-ballot", "name": "S_2_3_Manage_Standard_Reporting", "title": "S.2.3 Manage Standard Reporting (Function)", "status": "active", "date": "2025-04-03T15:15:30+00:00", "publisher": "EHR WG", "contact": [ { "telecom": [ { "system": "url", "value": "http://www.hl7.org/Special/committees/ehr" } ] } ], "description": "Enable PHR Account Holders or authorized designees to request and read pre-configured, packaged reports of PHR information.", "purpose": "PHR Account Holders may request standard, pre-configured, packaged reports. The purpose is not for PHR interchange but rather for PHR Account Holder’s analysis of his/her health related financial and administrative data, and for sharing (if desired).", "statement": [ { "extension": [ { "url": "http://hl7.org/ehrs/uv/phrsfmr2/StructureDefinition/requirements-dependent", "valueBoolean": false } ], "key": "PHRSFMR2-S.2.3-01", "label": "S.2.3#01", "conformance": [ "SHOULD" ], "conditionality": false, "requirement": "The system SHOULD provide the ability to render standard reports of structured clinical and administrative and financial data using either internal or external reporting tools.", "satisfiedBy": [ "https://www.hl7.org/fhir/measure.html" ] }, { "extension": [ { "url": "http://hl7.org/ehrs/uv/phrsfmr2/StructureDefinition/requirements-dependent", "valueBoolean": false } ], "key": "PHRSFMR2-S.2.3-02", "label": "S.2.3#02", "conformance": [ "SHOULD" ], "conditionality": false, "requirement": "The system SHOULD provide the ability to maintain report parameters based on data sorted or filtered by the PHR Account Holder or by the PHR-S settings." }, { "extension": [ { "url": "http://hl7.org/ehrs/uv/phrsfmr2/StructureDefinition/requirements-dependent", "valueBoolean": false } ], "key": "PHRSFMR2-S.2.3-03", "label": "S.2.3#03", "conformance": [ "MAY" ], "conditionality": false, "requirement": "The system MAY provide the ability to render information from unstructured clinical and administrative data in the report generation process using internal or external tools." }, { "extension": [ { "url": "http://hl7.org/ehrs/uv/phrsfmr2/StructureDefinition/requirements-dependent", "valueBoolean": false } ], "key": "PHRSFMR2-S.2.3-04", "label": "S.2.3#04", "conformance": [ "MAY" ], "conditionality": false, "requirement": "The system (or an external application using data from the PHR-S) MAY provide the ability to maintain report parameters for generating subsequent reports." }, { "extension": [ { "url": "http://hl7.org/ehrs/uv/phrsfmr2/StructureDefinition/requirements-dependent", "valueBoolean": false } ], "key": "PHRSFMR2-S.2.3-05", "label": "S.2.3#05", "conformance": [ "MAY" ], "conditionality": false, "requirement": "The system (or an external application using data from the PHR-S) MAY provide the ability to update one or more parameters of a saved report specification when generating a report using that specification." } ] }