FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: Requirements/EHRSFMR2-TI.5.1.1

Packagehl7.ehrs.uv.ehrsfmr2
TypeRequirements
IdEHRSFMR2-TI.5.1.1
FHIR VersionR5
Sourcehttp://hl7.org/ehrs/uv/ehrsfmr2/https://build.fhir.org/ig/mvdzel/ehrsfm-fhir-r5/Requirements-EHRSFMR2-TI.5.1.1.html
URLhttp://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-TI.5.1.1
Version2.1.1-ballot
Statusactive
Date2025-05-13T15:11:00+00:00
NameTI_5_1_1_Application_Interchange_Standards
TitleTI.5.1.1 Application Interchange Standards (Function)
Realmuv
Authorityhl7
DescriptionSupport the ability to operate seamlessly with other systems by using applications, and/or structured messages and documents that adhere to interchange standards.
PurposePlaceholder - Not Defined at this time

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Statement N:

Support the ability to operate seamlessly with other systems by using applications, and/or structured messages and documents that adhere to interchange standards.

Description I:

Placeholder - Not Defined at this time

Actors:
ehr
Criteria N:
TI.5.1.1#01 SHALL

The system SHALL provide the ability to receive and transmit information using interchange standards as required by realm / local -specific profiles, and/or by recognized jurisdictional authorities.

TI.5.1.1#02 SHALL

The system SHALL provide the ability to integrate with the operations of other systems that adhere to interchange standards as required by realm / local -specific authorities and/or by recognized jurisdictional authorities.

TI.5.1.1#03 dependent SHALL

The system SHALL conform to function TI.4 (Standard Terminology and Terminology Services) including all child-functions, to support terminology standards according to scope of practice, organizational policy, and/or jurisdictional law.

TI.5.1.1#04 conditional SHOULD

IF a standard information model is not available, THEN the system SHOULD provide the ability to exchange information with other systems in a seamless manner by using a formal explicit information model.

TI.5.1.1#05 MAY

The system MAY provide the ability to exchange information with other systems by using an explicit formal information model, and/or by using a standard coded terminology.

TI.5.1.1#06 SHALL

The system SHALL provide the ability to receive and transmit data using standard, coded terminology.

TI.5.1.1#07 SHOULD

The system SHOULD provide the ability to export data using an explicit and formal information model in accordance with industry and governmental-mandated standards.

TI.5.1.1#08 SHOULD

The system SHOULD provide the ability to import data using an explicit and formal information model in accordance with industry and governmental-mandated standards.

TI.5.1.1#09 SHOULD

The system SHOULD provide the ability to harmonize data with another system.

TI.5.1.1#10 SHOULD

The system SHOULD provide the ability to determine whether the information transmitted to another system has been successfully received by that other system.

TI.5.1.1#11 SHALL

The system SHALL store a log record of each data exchange (transaction) when transmitting information with external systems.


Source

{
  "resourceType": "Requirements",
  "id": "EHRSFMR2-TI.5.1.1",
  "meta": {
    "profile": [
      "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/FMFunction"
    ]
  },
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "ehr"
    }
  ],
  "url": "http://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-TI.5.1.1",
  "version": "2.1.1-ballot",
  "name": "TI_5_1_1_Application_Interchange_Standards",
  "title": "TI.5.1.1 Application Interchange Standards (Function)",
  "status": "active",
  "date": "2025-05-13T15:11:00+00:00",
  "publisher": "HL7 International / Electronic Health Records",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description": "Support the ability to operate seamlessly with other systems by using applications, and/or structured messages and documents that adhere to interchange standards.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "purpose": "Placeholder - Not Defined at this time",
  "statement": [
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-01",
      "label": "TI.5.1.1#01",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL provide the ability to receive and transmit information using interchange standards as required by realm / local -specific profiles, and/or by recognized jurisdictional authorities.",
      "derivedFrom": "EHR-S_FM_R1.1 IN.5.1#1"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-02",
      "label": "TI.5.1.1#02",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL provide the ability to integrate with the operations of other systems that adhere to interchange standards as required by realm / local -specific authorities and/or by recognized jurisdictional authorities.",
      "derivedFrom": "EHR-S_FM_R1.1 IN.5.1#2"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": true
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-03",
      "label": "TI.5.1.1#03",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL conform to function [TI.4](Requirements-EHRSFMR2-TI.4.html) (Standard Terminology and Terminology Services) including all child-functions, to support terminology standards according to scope of practice, organizational policy, and/or jurisdictional law.",
      "derivedFrom": "EHR-S_FM_R1.1 IN.5.1#3"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-04",
      "label": "TI.5.1.1#04",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": true,
      "requirement": "IF a standard information model is not available, THEN the system SHOULD provide the ability to exchange information with other systems in a seamless manner by using a formal explicit information model.",
      "derivedFrom": "EHR-S_FM_R1.1 IN.5.1#4"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-05",
      "label": "TI.5.1.1#05",
      "conformance": [
        "MAY"
      ],
      "conditionality": false,
      "requirement": "The system MAY provide the ability to exchange information with other systems by using an explicit formal information model, and/or by using a standard coded terminology.",
      "derivedFrom": "EHR-S_FM_R1.1 IN.5.1#5"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-06",
      "label": "TI.5.1.1#06",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL provide the ability to receive and transmit data using standard, coded terminology."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-07",
      "label": "TI.5.1.1#07",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "The system SHOULD provide the ability to export data using an explicit and formal information model in accordance with industry and governmental-mandated standards."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-08",
      "label": "TI.5.1.1#08",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "The system SHOULD provide the ability to import data using an explicit and formal information model in accordance with industry and governmental-mandated standards."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-09",
      "label": "TI.5.1.1#09",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "The system SHOULD provide the ability to harmonize data with another system."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-10",
      "label": "TI.5.1.1#10",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "The system SHOULD provide the ability to determine whether the information transmitted to another system has been successfully received by that other system."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-TI.5.1.1-11",
      "label": "TI.5.1.1#11",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL store a log record of each data exchange (transaction) when transmitting information with external systems."
    }
  ]
}