FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: Requirements/EHRSFMR2-RI.1.1.7

Packagehl7.ehrs.uv.ehrsfmr2
TypeRequirements
IdEHRSFMR2-RI.1.1.7
FHIR VersionR5
Sourcehttp://hl7.org/ehrs/uv/ehrsfmr2/https://build.fhir.org/ig/mvdzel/ehrsfm-fhir-r5/Requirements-EHRSFMR2-RI.1.1.7.html
URLhttp://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-RI.1.1.7
Version2.1.1-ballot
Statusactive
Date2025-05-13T15:11:00+00:00
NameRI_1_1_7_Disclose_Record_Lifecycle_Event
TitleRI.1.1.7 Disclose Record Lifecycle Event (Function)
Realmuv
Authorityhl7
DescriptionDisclose Record Entry Content (1 or more instances)
PurposeOccurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content. Reference: ISO 21089-2018, Section 15.7.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Statement N:

Disclose Record Entry Content (1 or more instances)

Description I:

Occurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content.

Reference: ISO 21089-2018, Section 15.7.

Actors:
ehr
Criteria N:
RI.1.1.7#01 SHALL

The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted/disclosed.

RI.1.1.7#02 dependent SHALL

The system SHALL capture a log entry for disclosure of protected Record Entry content, according to scope of practice, organizational policy, and/or jurisdictional law.

RI.1.1.7#03 dependent conditional SHOULD

IF the identity of a specific recipient has been stored, THEN the system SHOULD render protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law.

RI.1.1.7#04 conditional SHOULD

IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions.

RI.1.1.7#05 SHALL

The system SHALL conform to function TI.1.6 (Secure Data Exchange).

RI.1.1.7#06 SHALL

The system SHALL provide the ability to extract Record Entry content prior to disclosure, conforming to function RI.1.1.13 (Extract Record Entry Content).

RI.1.1.7#07 SHALL

The system SHALL provide the ability to de-identify Record Entry content prior to disclosure, conforming to function RI.1.1.10 (De-Identify Record Entries).


Source

{
  "resourceType": "Requirements",
  "id": "EHRSFMR2-RI.1.1.7",
  "meta": {
    "profile": [
      "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/FMFunction"
    ]
  },
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "ehr"
    }
  ],
  "url": "http://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-RI.1.1.7",
  "version": "2.1.1-ballot",
  "name": "RI_1_1_7_Disclose_Record_Lifecycle_Event",
  "title": "RI.1.1.7 Disclose Record Lifecycle Event (Function)",
  "status": "active",
  "date": "2025-05-13T15:11:00+00:00",
  "publisher": "HL7 International / Electronic Health Records",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description": "Disclose Record Entry Content (1 or more instances)",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "purpose": "Occurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content. \n\nReference: ISO 21089-2018, Section 15.7.",
  "statement": [
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.7-01",
      "label": "RI.1.1.7#01",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL provide the ability to capture the identity of the patient or individual subject to whom Record Entry content was transmitted/disclosed."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": true
        }
      ],
      "key": "EHRSFMR2-RI.1.1.7-02",
      "label": "RI.1.1.7#02",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture a log entry for disclosure of protected Record Entry content, according to scope of practice, organizational policy, and/or jurisdictional law."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": true
        }
      ],
      "key": "EHRSFMR2-RI.1.1.7-03",
      "label": "RI.1.1.7#03",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": true,
      "requirement": "IF the identity of a specific recipient has been stored, THEN the system SHOULD render protected Record Entry content based on established permissions and according to scope of practice, organizational policy, and/or jurisdictional law."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.7-04",
      "label": "RI.1.1.7#04",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": true,
      "requirement": "IF known and explicit as to Record Entry content being transmitted, THEN the system SHOULD transmit corresponding authorizations and patient consent permissions."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.7-05",
      "label": "RI.1.1.7#05",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL conform to function [TI.1.6](Requirements-EHRSFMR2-TI.1.6.html) (Secure Data Exchange)."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.7-06",
      "label": "RI.1.1.7#06",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL provide the ability to extract Record Entry content prior to disclosure, conforming to function [RI.1.1.13](Requirements-EHRSFMR2-RI.1.1.13.html) (Extract Record Entry Content)."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.7-07",
      "label": "RI.1.1.7#07",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL provide the ability to de-identify Record Entry content prior to disclosure, conforming to function [RI.1.1.10](Requirements-EHRSFMR2-RI.1.1.10.html) (De-Identify Record Entries)."
    }
  ]
}