FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: Requirements/EHRSFMR2-RI.1.1.6.1

Packagehl7.ehrs.uv.ehrsfmr2
TypeRequirements
IdEHRSFMR2-RI.1.1.6.1
FHIR VersionR5
Sourcehttp://hl7.org/ehrs/uv/ehrsfmr2/https://build.fhir.org/ig/mvdzel/ehrsfm-fhir-r5/Requirements-EHRSFMR2-RI.1.1.6.1.html
URLhttp://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-RI.1.1.6.1
Version2.1.1-ballot
Statusactive
Date2025-05-13T15:11:00+00:00
NameRI_1_1_6_1_Evidence_of_Record_Entry_Output_Report_Event
TitleRI.1.1.6.1 Evidence of Record Entry Output/Report Event (Function)
Realmuv
Authorityhl7
DescriptionMaintain Evidence of Record Entry Output/Report Event
PurposeEvidence of Record Entry Output/Report Event includes key metadata, ensures health record integrity (and trust) and enables record audit.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Statement N:

Maintain Evidence of Record Entry Output/Report Event

Description I:

Evidence of Record Entry Output/Report Event includes key metadata, ensures health record integrity (and trust) and enables record audit.

Actors:
ehr
Criteria N:
RI.1.1.6.1#01 SHALL

The system SHALL audit each occurrence when an output (e.g., report, screen shot) is generated from Record Entry content.

RI.1.1.6.1#02 SHALL

The system SHALL capture identity of the organization where output/report is generated from Record Entry content.

RI.1.1.6.1#03 SHALL

The system SHALL capture identity of the patient who is subject of the Record Entry(ies) populating the output/report generated.

RI.1.1.6.1#04 SHALL

The system SHALL capture identity of the user who generated the output/report of Record Entry content.

RI.1.1.6.1#05 SHALL

The system SHALL capture identity of the system application from which the output/report is generated.

RI.1.1.6.1#06 SHALL

The system SHALL capture the type of Record Event trigger (i.e., output/report).

RI.1.1.6.1#07 SHALL

The system SHALL capture the date and time the output/report is generated.

RI.1.1.6.1#08 SHOULD

The system SHOULD capture identity of the location (i.e., network address) where the output/report is generated.

RI.1.1.6.1#09 MAY

The system MAY capture the rationale for generating the output/report.

RI.1.1.6.1#10 MAY

The system MAY capture the data, document, or other identifier for the output/report generated.

RI.1.1.6.1#11 dependent SHALL

The system SHALL capture when a Record Entry content output/report occurrence is known to be a disclosure, according to scope of practice, organizational policy, and/or jurisdictional law.

RI.1.1.6.1#12 SHOULD

The system SHOULD capture known and applicable permissions regarding Record Entry content output/reported including confidentiality codes, patient consent authorizations, privacy policy pointers.


Source

{
  "resourceType": "Requirements",
  "id": "EHRSFMR2-RI.1.1.6.1",
  "meta": {
    "profile": [
      "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/FMFunction"
    ]
  },
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "ehr"
    }
  ],
  "url": "http://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-RI.1.1.6.1",
  "version": "2.1.1-ballot",
  "name": "RI_1_1_6_1_Evidence_of_Record_Entry_Output_Report_Event",
  "title": "RI.1.1.6.1 Evidence of Record Entry Output/Report Event (Function)",
  "status": "active",
  "date": "2025-05-13T15:11:00+00:00",
  "publisher": "HL7 International / Electronic Health Records",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description": "Maintain Evidence of Record Entry Output/Report Event",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "purpose": "Evidence of Record Entry Output/Report Event includes key metadata, ensures health record integrity (and trust) and enables record audit.",
  "statement": [
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-01",
      "label": "RI.1.1.6.1#01",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL audit each occurrence when an output (e.g., report, screen shot) is generated from Record Entry content."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-02",
      "label": "RI.1.1.6.1#02",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture identity of the organization where output/report is generated from Record Entry content."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-03",
      "label": "RI.1.1.6.1#03",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture identity of the patient who is subject of the Record Entry(ies) populating the output/report generated."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-04",
      "label": "RI.1.1.6.1#04",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture identity of the user who generated the output/report of Record Entry content."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-05",
      "label": "RI.1.1.6.1#05",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture identity of the system application from which the output/report is generated."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-06",
      "label": "RI.1.1.6.1#06",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture the type of Record Event trigger (i.e., output/report)."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-07",
      "label": "RI.1.1.6.1#07",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture the date and time the output/report is generated."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-08",
      "label": "RI.1.1.6.1#08",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "The system SHOULD capture identity of the location (i.e., network address) where the output/report is generated."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-09",
      "label": "RI.1.1.6.1#09",
      "conformance": [
        "MAY"
      ],
      "conditionality": false,
      "requirement": "The system MAY capture the rationale for generating the output/report."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-10",
      "label": "RI.1.1.6.1#10",
      "conformance": [
        "MAY"
      ],
      "conditionality": false,
      "requirement": "The system MAY capture the data, document, or other identifier for the output/report generated."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": true
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-11",
      "label": "RI.1.1.6.1#11",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "The system SHALL capture when a Record Entry content output/report occurrence is known to be a disclosure, according to scope of practice, organizational policy, and/or jurisdictional law."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/ehrs/uv/ehrsfmr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "EHRSFMR2-RI.1.1.6.1-12",
      "label": "RI.1.1.6.1#12",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "The system SHOULD capture known and applicable permissions regarding Record Entry content output/reported including confidentiality codes, patient consent authorizations, privacy policy pointers."
    }
  ]
}