URLhttp://www.ieb.ufsc.br/fhir/StructureDefinition/Observation-resprate-ieb
Version1.0.0
Statusactive
Date2021-05-21
NameObservationRespRateIEB
TitleObservation Respiratory Rate (IEB)
Realmus
Authorityhl7
DescriptionFHIR Respiratory Rate Profile
TypeObservation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Overview

Name: ObservationRespRateIEB

Title: Observation Respiratory Rate (IEB)

Status: Active

URL: http://www.ieb.ufsc.br/fhir/StructureDefinition/Observation-resprate-ieb

Publisher: Health Level Seven International (Orders and Observations Workgroup)


Source

{
  "resourceType": "StructureDefinition",
  "id": "Observation-resprate-ieb",
  "meta": {
    "versionId": "5",
    "lastUpdated": "2021-05-21T19:50:40.893+00:00",
    "source": "#IB2eTIB4jdXqtQPL"
  },
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-summary",
      "valueMarkdown": "#### Complete Summary of the Mandatory Requirements\r\r1.  One code in `Observation.code` which must have\r    -   a fixed `Observation.code.coding.system`=**'http ://loinc.org'**\r    -   a fixed  `Observation.code.coding.code`= **'9279-1'**\r    -   Other additional Codings are allowed in `Observation.code`- e.g. more specific LOINC\r        Codes, SNOMED CT concepts, system specific codes. All codes\r        SHALL have an system value\r1. Either one Observation.valueQuantity or, if there is no value, one code in Observation.DataAbsentReason\r   - Each Observation.valueQuantity must have:\r     - One numeric value in Observation.valueQuantity.value\r     - a fixed Observation.valueQuantity.system=\"http://unitsofmeasure.org\"\r     - a UCUM unit code in Observation.valueQuantity.code = **'/min'**"
    }
  ],
  "url": "http://www.ieb.ufsc.br/fhir/StructureDefinition/Observation-resprate-ieb",
  "version": "1.0.0",
  "name": "ObservationRespRateIEB",
  "title": "Observation Respiratory Rate (IEB)",
  "status": "active",
  "experimental": false,
  "date": "2021-05-21",
  "publisher": "Health Level Seven International (Orders and Observations Workgroup)",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/orders/index.cfm Orders and Observations"
        }
      ]
    }
  ],
  "description": "FHIR Respiratory Rate Profile",
  "fhirVersion": "4.0.1",
  "mapping": [
    {
      "identity": "workflow",
      "uri": "http://hl7.org/fhir/workflow",
      "name": "Workflow Pattern"
    },
    {
      "identity": "sct-concept",
      "uri": "http://snomed.info/conceptdomain",
      "name": "SNOMED CT Concept Domain Binding"
    },
    {
      "identity": "v2",
      "uri": "http://hl7.org/v2",
      "name": "HL7 v2 Mapping"
    },
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    },
    {
      "identity": "w5",
      "uri": "http://hl7.org/fhir/fivews",
      "name": "FiveWs Pattern Mapping"
    },
    {
      "identity": "sct-attr",
      "uri": "http://snomed.org/attributebinding",
      "name": "SNOMED CT Attribute Binding"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/vitalsigns",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation",
        "path": "Observation",
        "short": "FHIR Respiratory Rate Profile",
        "definition": "This profile defines  how to represent Respiratory Rate observations in FHIR using a standard LOINC code and UCUM units of measure.",
        "min": 0,
        "max": "*"
      },
      {
        "id": "Observation.code",
        "path": "Observation.code",
        "short": "Respiratory Rate",
        "definition": "Respiratory Rate.",
        "comment": "additional codes that translate or map to this code are allowed.  For example a more granular LOINC code or code that is used locally in a system.",
        "alias": [
          "Test",
          "Name"
        ]
      },
      {
        "id": "Observation.code.coding",
        "path": "Observation.code.coding",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "code"
            },
            {
              "type": "value",
              "path": "system"
            }
          ],
          "ordered": false,
          "rules": "open"
        }
      },
      {
        "id": "Observation.code.coding:RespRateCode",
        "path": "Observation.code.coding",
        "sliceName": "RespRateCode",
        "min": 1,
        "max": "1"
      },
      {
        "id": "Observation.code.coding:RespRateCode.system",
        "path": "Observation.code.coding.system",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "uri"
          }
        ],
        "fixedUri": "http://loinc.org"
      },
      {
        "id": "Observation.code.coding:RespRateCode.code",
        "path": "Observation.code.coding.code",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "code"
          }
        ],
        "fixedCode": "9279-1"
      },
      {
        "id": "Observation.valueQuantity",
        "path": "Observation.valueQuantity"
      },
      {
        "id": "Observation.valueQuantity.value",
        "path": "Observation.valueQuantity.value",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "decimal"
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.valueQuantity.unit",
        "path": "Observation.valueQuantity.unit",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "string"
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.valueQuantity.system",
        "path": "Observation.valueQuantity.system",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "uri"
          }
        ],
        "fixedUri": "http://unitsofmeasure.org",
        "mustSupport": true
      },
      {
        "id": "Observation.valueQuantity.code",
        "path": "Observation.valueQuantity.code",
        "short": "Coded responses from the common UCUM units for vital signs value set.",
        "definition": "Coded responses from the common UCUM units for vital signs value set.",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "code"
          }
        ],
        "fixedCode": "/min",
        "mustSupport": true
      }
    ]
  }
}