"resourceType": "ValueSet",
"id": "dicom-cid-6041-MammographyImageQualityFinding",
"url": "http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6041.html",
"identifier": [
{
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:1.2.840.10008.6.1.371"
}
],
"version": "2025.3.20250714",
"name": "MammographyImageQualityFinding",
"status": "active",
"experimental": false,
"date": "2025-07-14",
"publisher": "NEMA MITA DICOM",
"description": "Transitive closure of CID 6041 MammographyImageQualityFinding",
"copyright": "© 2025 NEMA",
"compose": {
"include": [
{
"system": "http://dicom.nema.org/resources/ontology/DCM",
"concept": [
{
"code": "111182",
"display": "View and Laterality Marker is partially obscured"
},
{
"code": "111183",
"display": "View and Laterality Marker is incorrect"
},
{
"code": "111184",
"display": "View and Laterality Marker is off image"
},
{
"code": "111185",
"display": "Flash is not near edge of film"
},
{
"code": "111186",
"display": "Flash is illegible, does not fit, or is lopsided"
},
{
"code": "111187",
"display": "Flash doesn't include patient name and additional patient id"
},
{
"code": "111220",
"display": "Other failure"
},
{
"code": "111188",
"display": "Flash doesn't include date of examination"
},
{
"code": "111221",
"display": "Unknown failure"
},
{
"code": "111189",
"display": "Flash doesn't include facility name and location"
},
{
"code": "111200",
"display": "MLO Evidence of motion blur"
},
{
"code": "111180",
"display": "View and Laterality Marker is not near the axilla"
},
{
"code": "111181",
"display": "View and Laterality Marker overlaps breast tissue"
},
{
"code": "111209",
"display": "Positioning"
},
{
"code": "111201",
"display": "MLO Inframammary fold is not open"
},
{
"code": "111202",
"display": "CC Not all medial tissue visualized"
},
{
"code": "111203",
"display": "CC Nipple not centered on image"
},
{
"code": "111204",
"display": "CC Posterior nipple line does not measure within 1 cm of MLO"
},
{
"code": "111205",
"display": "Nipple not in profile"
},
{
"code": "111206",
"display": "Insufficient implant displacement incorrect"
},
{
"code": "111208",
"display": "Grid artifact(s)"
},
{
"code": "111193",
"display": "Date sticker is missing"
},
{
"code": "111194",
"display": "Technical factors missing"
},
{
"code": "111195",
"display": "Collimation too close to breast"
},
{
"code": "111196",
"display": "Inadequate compression"
},
{
"code": "111197",
"display": "MLO Insufficient pectoral muscle"
},
{
"code": "111198",
"display": "MLO No fat is visualized posterior to fibroglandular tissues"
},
{
"code": "111177",
"display": "View and Laterality Marker is missing"
},
{
"code": "111199",
"display": "MLO Poor separation of deep and superficial breast tissues"
},
{
"code": "111210",
"display": "Motion blur"
},
{
"code": "111178",
"display": "View and Laterality Marker does not have both view and laterality"
},
{
"code": "111211",
"display": "Under exposed"
},
{
"code": "111190",
"display": "Flash doesn't include technologist identification"
},
{
"code": "111191",
"display": "Flash doesn't include cassette/screen/detector identification"
},
{
"code": "111192",
"display": "Flash doesn't include mammography unit identification"
},
{
"code": "111179",
"display": "View and Laterality Marker does not have approved codes"
},
{
"code": "111212",
"display": "Over exposed"
},
{
"code": "111213",
"display": "No image"
},
{
"code": "111214",
"display": "Detector artifact(s)"
},
{
"code": "111215",
"display": "Artifact(s) other than grid or detector artifact"
},
{
"code": "111216",
"display": "Mechanical failure"
},
{
"code": "111217",
"display": "Electrical failure"
},
{
"code": "111218",
"display": "Software failure"
},
{
"code": "111219",
"display": "Inappropriate image processing"
}
]
}
]
}
}