FHIR © HL7.org  |  Server Home  |  XIG Home  |  XIG Stats  |  Server Source  |  FHIR  

FHIR IG Statistics: ValueSet/dicom-cid-6041-MammographyImageQualityFinding

Packagefhir.dicom
Resource TypeValueSet
Iddicom-cid-6041-MammographyImageQualityFinding
FHIR VersionR4
Sourcehttp://fhir.org/packages/fhir.dicom/http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6041.html
URLhttp://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6041.html
Version2025.3.20250714
Statusactive
Date2025-07-14
NameMammographyImageQualityFinding
Realmus
Authorityhl7
DescriptionTransitive closure of CID 6041 MammographyImageQualityFinding
Copyright© 2025 NEMA

Resources that use this resource

No resources found


Resources that this resource uses

CodeSystem
DCMDICOM Controlled Terminology

Narrative

No narrative content found in resource


Source

{
  "resourceType": "ValueSet",
  "id": "dicom-cid-6041-MammographyImageQualityFinding",
  "url": "http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_6041.html",
  "identifier": [
    {
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:1.2.840.10008.6.1.371"
    }
  ],
  "version": "2025.3.20250714",
  "name": "MammographyImageQualityFinding",
  "status": "active",
  "experimental": false,
  "date": "2025-07-14",
  "publisher": "NEMA MITA DICOM",
  "description": "Transitive closure of CID 6041 MammographyImageQualityFinding",
  "copyright": "© 2025 NEMA",
  "compose": {
    "include": [
      {
        "system": "http://dicom.nema.org/resources/ontology/DCM",
        "concept": [
          {
            "code": "111182",
            "display": "View and Laterality Marker is partially obscured"
          },
          {
            "code": "111183",
            "display": "View and Laterality Marker is incorrect"
          },
          {
            "code": "111184",
            "display": "View and Laterality Marker is off image"
          },
          {
            "code": "111185",
            "display": "Flash is not near edge of film"
          },
          {
            "code": "111186",
            "display": "Flash is illegible, does not fit, or is lopsided"
          },
          {
            "code": "111187",
            "display": "Flash doesn't include patient name and additional patient id"
          },
          {
            "code": "111220",
            "display": "Other failure"
          },
          {
            "code": "111188",
            "display": "Flash doesn't include date of examination"
          },
          {
            "code": "111221",
            "display": "Unknown failure"
          },
          {
            "code": "111189",
            "display": "Flash doesn't include facility name and location"
          },
          {
            "code": "111200",
            "display": "MLO Evidence of motion blur"
          },
          {
            "code": "111180",
            "display": "View and Laterality Marker is not near the axilla"
          },
          {
            "code": "111181",
            "display": "View and Laterality Marker overlaps breast tissue"
          },
          {
            "code": "111209",
            "display": "Positioning"
          },
          {
            "code": "111201",
            "display": "MLO Inframammary fold is not open"
          },
          {
            "code": "111202",
            "display": "CC Not all medial tissue visualized"
          },
          {
            "code": "111203",
            "display": "CC Nipple not centered on image"
          },
          {
            "code": "111204",
            "display": "CC Posterior nipple line does not measure within 1 cm of MLO"
          },
          {
            "code": "111205",
            "display": "Nipple not in profile"
          },
          {
            "code": "111206",
            "display": "Insufficient implant displacement incorrect"
          },
          {
            "code": "111208",
            "display": "Grid artifact(s)"
          },
          {
            "code": "111193",
            "display": "Date sticker is missing"
          },
          {
            "code": "111194",
            "display": "Technical factors missing"
          },
          {
            "code": "111195",
            "display": "Collimation too close to breast"
          },
          {
            "code": "111196",
            "display": "Inadequate compression"
          },
          {
            "code": "111197",
            "display": "MLO Insufficient pectoral muscle"
          },
          {
            "code": "111198",
            "display": "MLO No fat is visualized posterior to fibroglandular tissues"
          },
          {
            "code": "111177",
            "display": "View and Laterality Marker is missing"
          },
          {
            "code": "111199",
            "display": "MLO Poor separation of deep and superficial breast tissues"
          },
          {
            "code": "111210",
            "display": "Motion blur"
          },
          {
            "code": "111178",
            "display": "View and Laterality Marker does not have both view and laterality"
          },
          {
            "code": "111211",
            "display": "Under exposed"
          },
          {
            "code": "111190",
            "display": "Flash doesn't include technologist identification"
          },
          {
            "code": "111191",
            "display": "Flash doesn't include cassette/screen/detector identification"
          },
          {
            "code": "111192",
            "display": "Flash doesn't include mammography unit identification"
          },
          {
            "code": "111179",
            "display": "View and Laterality Marker does not have approved codes"
          },
          {
            "code": "111212",
            "display": "Over exposed"
          },
          {
            "code": "111213",
            "display": "No image"
          },
          {
            "code": "111214",
            "display": "Detector artifact(s)"
          },
          {
            "code": "111215",
            "display": "Artifact(s) other than grid or detector artifact"
          },
          {
            "code": "111216",
            "display": "Mechanical failure"
          },
          {
            "code": "111217",
            "display": "Electrical failure"
          },
          {
            "code": "111218",
            "display": "Software failure"
          },
          {
            "code": "111219",
            "display": "Inappropriate image processing"
          }
        ]
      }
    ]
  }
}