| Package | fhir.dicom |
| Resource Type | ValueSet |
| Id | dicom-cid-12119-VascularUltrasoundProperty |
| FHIR Version | R4 |
| Source | http://fhir.org/packages/fhir.dicom/http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12119.html |
| URL | http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12119.html |
| Version | 2025.3.20250714 |
| Status | active |
| Date | 2025-07-14 |
| Name | VascularUltrasoundProperty |
| Realm | us |
| Authority | hl7 |
| Description | Transitive closure of CID 12119 VascularUltrasoundProperty |
| Copyright | © 2025 NEMA |
No resources found
| CodeSystem | |
| DCM | DICOM Controlled Terminology |
| loinc.org | Logical Observation Identifiers, Names and Codes (LOINC) |
| sct | SNOMED CT International Edition |
No narrative content found in resource
{
"resourceType": "ValueSet",
"id": "dicom-cid-12119-VascularUltrasoundProperty",
"url": "http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_12119.html",
"identifier": [
{
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:1.2.840.10008.6.1.585"
}
],
"version": "2025.3.20250714",
"name": "VascularUltrasoundProperty",
"status": "active",
"experimental": false,
"date": "2025-07-14",
"publisher": "NEMA MITA DICOM",
"description": "Transitive closure of CID 12119 VascularUltrasoundProperty",
"copyright": "© 2025 NEMA",
"compose": {
"include": [
{
"system": "http://dicom.nema.org/resources/ontology/DCM",
"concept": [
{
"code": "110828",
"display": "Flow velocity"
}
]
},
{
"system": "http://loinc.org",
"concept": [
{
"code": "11665-7",
"display": "Minimum Diastolic Velocity"
},
{
"code": "12023-8",
"display": "Resistivity Index"
},
{
"code": "20354-7",
"display": "Velocity Time Integral"
},
{
"code": "20256-4",
"display": "Mean Gradient"
},
{
"code": "11726-7",
"display": "Peak Systolic Velocity"
},
{
"code": "33878-0",
"display": "Volume flow"
},
{
"code": "33867-3",
"display": "Velocity ratio"
},
{
"code": "11692-1",
"display": "Time averaged peak velocity"
},
{
"code": "11653-3",
"display": "End Diastolic Velocity"
},
{
"code": "20247-3",
"display": "Peak Gradient"
},
{
"code": "20167-3",
"display": "Acceleration Index"
},
{
"code": "20217-6",
"display": "Deceleration Time"
},
{
"code": "20168-1",
"display": "Acceleration Time"
},
{
"code": "12144-2",
"display": "Systolic to Diastolic Velocity Ratio"
},
{
"code": "20355-4",
"display": "Peak Blood Velocity"
},
{
"code": "12008-9",
"display": "Pulsatility Index"
},
{
"code": "20352-1",
"display": "Time averaged mean velocity"
}
]
},
{
"system": "http://snomed.info/sct",
"concept": [
{
"code": "413975003",
"display": "Vessel depth from surface"
},
{
"code": "397414006",
"display": "Vessel outside diameter"
},
{
"code": "415814008",
"display": "Vessel Intimal Cross-Sectional Diameter"
},
{
"code": "408715008",
"display": "Lumen Diameter Stenosis"
},
{
"code": "397413000",
"display": "Vessel lumen diameter"
},
{
"code": "414599003",
"display": "Length of Segment"
},
{
"code": "397415007",
"display": "Vessel lumen cross-sectional area"
},
{
"code": "408714007",
"display": "Lumen Area Stenosis"
},
{
"code": "415815009",
"display": "Vessel Intimal Diameter"
}
]
},
{
"system": "http://snomed.info/srt",
"concept": [
{
"code": "R-101BA",
"display": "Lumen Area Stenosis"
},
{
"code": "R-101BB",
"display": "Lumen Diameter Stenosis"
},
{
"code": "G-0366",
"display": "Vessel lumen cross-sectional area"
},
{
"code": "G-0364",
"display": "Vessel lumen diameter"
},
{
"code": "G-0365",
"display": "Vessel outside diameter"
},
{
"code": "R-1025C",
"display": "Vessel Intimal Diameter"
},
{
"code": "R-1025F",
"display": "Length of Segment"
},
{
"code": "R-1025E",
"display": "Vessel depth from surface"
},
{
"code": "R-1025D",
"display": "Vessel Intimal Cross-Sectional Diameter"
}
]
}
]
}
}