Package | fhir.dicom |
Resource Type | ValueSet |
Id | dicom-cid-3688-ElectrophysiologyWaveformVoltage |
FHIR Version | R4 |
Source | http://fhir.org/packages/fhir.dicom/http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3688.html |
URL | http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3688.html |
Version | 2025.2.20250411 |
Status | active |
Date | 2025-04-11 |
Name | ElectrophysiologyWaveformVoltage |
Realm | us |
Authority | hl7 |
Description | Transitive closure of CID 3688 ElectrophysiologyWaveformVoltage |
Copyright | © 2025 NEMA |
No resources found
CodeSystem | |
urn:iso:std:iso:11073:10101 | ISO/IEEE 11073 Medical Device Communication Nomenclature |
No narrative content found in resource
{ "resourceType": "ValueSet", "id": "dicom-cid-3688-ElectrophysiologyWaveformVoltage", "url": "http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_3688.html", "identifier": [ { "system": "urn:ietf:rfc:3986", "value": "urn:oid:1.2.840.10008.6.1.202" } ], "version": "2025.2.20250411", "name": "ElectrophysiologyWaveformVoltage", "status": "active", "experimental": false, "date": "2025-04-11", "publisher": "NEMA MITA DICOM", "description": "Transitive closure of CID 3688 ElectrophysiologyWaveformVoltage", "copyright": "© 2025 NEMA", "compose": { "include": [ { "system": "urn:iso:std:iso:11073:10101", "concept": [ { "code": "2:1536", "display": "P minimum amplitude, per lead" }, { "code": "2:12800", "display": "R1 amplitude, per lead" }, { "code": "2:13824", "display": "S2 amplitude, per lead" }, { "code": "2:14848", "display": "Amplitude at 20 ms into ST segment, per lead" }, { "code": "2:768", "display": "ST amplitude, per lead" }, { "code": "2:2816", "display": "T minimum amplitude, per lead" }, { "code": "2:2304", "display": "S amplitude, per lead" }, { "code": "2:13568", "display": "S1 amplitude, per lead" }, { "code": "2:15104", "display": "Amplitude at 40 ms into ST segment, per lead" }, { "code": "2:1792", "display": "Q amplitude, per lead" }, { "code": "2:2048", "display": "R amplitude, per lead" }, { "code": "2:13312", "display": "R3 amplitude, per lead" }, { "code": "2:14336", "display": "Amplitude at 60 ms into ST segment, per lead" }, { "code": "2:2560", "display": "T maximum amplitude, per lead" }, { "code": "2:1024", "display": "J point Amplitude, per lead" }, { "code": "2:13056", "display": "R2 amplitude, per lead" }, { "code": "2:3072", "display": "P3 amplitude, per lead" }, { "code": "2:14592", "display": "Amplitude at 80 ms into ST segment, per lead" }, { "code": "2:14080", "display": "S3 amplitude, per lead" }, { "code": "2:1280", "display": "P maximum amplitude, per lead" } ] } ] } }