FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagefdpg.query_profiles
Resource TypeStructureDefinition
Id95ec57f3-5187-45f4-9bcd-7fea09e8fe76
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=fdpg.query_profiles@0.0.6-alpha&canonical=https://www.medizininformatik-initiative.de/fhir/fdpg/StructureDefinition/Protein[Presence]inUrinebyAutomatedteststrip
URLhttps://www.medizininformatik-initiative.de/fhir/fdpg/StructureDefinition/Protein[Presence]inUrinebyAutomatedteststrip
Statusactive
NameProtein [Presence] in Urine by Automated test strip
TypeObservation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
ObservationLabMII PR Labor Laboruntersuchung

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "url": "https://www.medizininformatik-initiative.de/fhir/fdpg/StructureDefinition/Protein[Presence]inUrinebyAutomatedteststrip",
  "name": "Protein [Presence] in Urine by Automated test strip",
  "status": "active",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "https://www.medizininformatik-initiative.de/fhir/core/modul-labor/StructureDefinition/ObservationLab",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.code",
        "path": "Observation.code",
        "short": "Protein [Presence] in Urine by Automated test strip",
        "definition": "Protein [Presence] in Urine by Automated test strip"
      },
      {
        "id": "Observation.code.coding",
        "path": "Observation.code.coding",
        "slicing": {
          "discriminator": [
            {
              "type": "pattern",
              "path": "$this"
            }
          ],
          "rules": "open"
        },
        "min": 1
      },
      {
        "id": "Observation.code.coding:loinc",
        "path": "Observation.code.coding",
        "sliceName": "loinc",
        "min": 1,
        "max": "*",
        "patternCoding": {
          "system": "http://loinc.org",
          "code": "57735-3"
        }
      },
      {
        "id": "Observation.code.coding:loinc.system",
        "path": "Observation.code.coding.system",
        "min": 1
      },
      {
        "id": "Observation.code.coding:loinc.code",
        "path": "Observation.code.coding.code",
        "min": 1
      },
      {
        "id": "observation.subject.reference",
        "path": "Observation.subject.reference",
        "min": 1
      },
      {
        "id": "Observation.value[x]",
        "path": "Observation.value[x]",
        "slicing": {
          "discriminator": [
            {
              "type": "type",
              "path": "$this"
            }
          ],
          "ordered": false,
          "rules": "open"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": true,
        "min": 1
      },
      {
        "id": "Observation.value[x]:valueCodeableConcept",
        "path": "Observation.value[x]",
        "sliceName": "valueCodeableConcept",
        "min": 1,
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/core/modul-labor/ValueSet/Laborergebnis-qualitativ-fdpg"
        }
      }
    ]
  },
  "id": "95ec57f3-5187-45f4-9bcd-7fea09e8fe76"
}