FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagefdpg.query_profiles
Resource TypeStructureDefinition
Id14b3dc84-8a40-4eee-8d59-936340b75931
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=fdpg.query_profiles@0.0.6-alpha&canonical=https://www.medizininformatik-initiative.de/fhir/fdpg/StructureDefinition/SpecificgravityofUrinebyTeststrip
URLhttps://www.medizininformatik-initiative.de/fhir/fdpg/StructureDefinition/SpecificgravityofUrinebyTeststrip
Statusactive
NameSpecific gravity of Urine by Test strip
TypeObservation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
ObservationLabMII PR Labor Laboruntersuchung

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "url": "https://www.medizininformatik-initiative.de/fhir/fdpg/StructureDefinition/SpecificgravityofUrinebyTeststrip",
  "name": "Specific gravity of Urine by Test strip",
  "status": "active",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "https://www.medizininformatik-initiative.de/fhir/core/modul-labor/StructureDefinition/ObservationLab",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.code",
        "path": "Observation.code",
        "short": "Specific gravity of Urine by Test strip",
        "definition": "Specific gravity of Urine by Test strip"
      },
      {
        "id": "Observation.code.coding",
        "path": "Observation.code.coding",
        "slicing": {
          "discriminator": [
            {
              "type": "pattern",
              "path": "$this"
            }
          ],
          "rules": "open"
        },
        "min": 1
      },
      {
        "id": "Observation.code.coding:loinc",
        "path": "Observation.code.coding",
        "sliceName": "loinc",
        "min": 1,
        "max": "*",
        "patternCoding": {
          "system": "http://loinc.org",
          "code": "5811-5"
        }
      },
      {
        "id": "Observation.code.coding:loinc.system",
        "path": "Observation.code.coding.system",
        "min": 1
      },
      {
        "id": "Observation.code.coding:loinc.code",
        "path": "Observation.code.coding.code",
        "min": 1
      },
      {
        "id": "observation.subject.reference",
        "path": "Observation.subject.reference",
        "min": 1
      },
      {
        "id": "Observation.value[x]",
        "path": "Observation.value[x]",
        "slicing": {
          "discriminator": [
            {
              "type": "type",
              "path": "$this"
            }
          ],
          "ordered": false,
          "rules": "open"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "mustSupport": true,
        "min": 1
      },
      {
        "id": "Observation.value[x]:valueCodeableConcept",
        "path": "Observation.value[x]",
        "sliceName": "valueCodeableConcept",
        "min": 1,
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/core/modul-labor/ValueSet/Laborergebnis-qualitativ-fdpg"
        }
      }
    ]
  },
  "id": "14b3dc84-8a40-4eee-8d59-936340b75931"
}