FHIR IG analytics| Package | de.medizininformatikinitiative.kerndatensatz.onkologie |
| Resource Type | Procedure |
| Id | Procedure-mii-exa-onko-strahlentherapie-bestrahlung-pci-sclc.json |
| FHIR Version | R4 |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
English
Generated Narrative: Procedure mii-exa-onko-strahlentherapie-bestrahlung-pci-sclc
Profile: MII PR Onkologie Strahlentherapie version: 2027.0.0-ballot.1
Procedure Method: perkutan ohne Chemotherapie/Sensitizer
MII EX Onko Strahlentherapie Bestrahlung Gesamtdosis: 25 Gy
MII EX Onko Strahlentherapie Bestrahlung Einzeldosis: 2.5 Gy
partOf: Procedure Strahlentherapie
status: Completed
category: Radiotherapy (procedure)
code: Strahlentherapie
subject: Erika Beispiel Female, DoB: 1965-04-12
performed: 2026-05-04 --> 2026-05-18
bodySite: Ganzhirn (Neurokranium, inklusive Meningen)
usedCode: Protonen (leichte Wasserstoffionen/H1/Leichtionen)
German
Generated Narrative: Procedure mii-exa-onko-strahlentherapie-bestrahlung-pci-sclc
Profile: MII PR Onkologie Strahlentherapie version: 2027.0.0-ballot.1
Procedure Method: perkutan ohne Chemotherapie/Sensitizer
MII EX Onko Strahlentherapie Bestrahlung Gesamtdosis: 25 Gy
MII EX Onko Strahlentherapie Bestrahlung Einzeldosis: 2.5 Gy
partOf: Procedure Strahlentherapie
status: Completed
category: Radiotherapy (procedure)
code: Strahlentherapie
subject: Erika Beispiel Female, DoB: 1965-04-12
performed: 2026-05-04 --> 2026-05-18
bodySite: Ganzhirn (Neurokranium, inklusive Meningen)
usedCode: Protonen (leichte Wasserstoffionen/H1/Leichtionen)
{
"resourceType": "Procedure",
"id": "mii-exa-onko-strahlentherapie-bestrahlung-pci-sclc",
"meta": {
"profile": [
"https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/StructureDefinition/mii-pr-onko-strahlentherapie-bestrahlung-strahlentherapie|2027.0.0-ballot.1"
]
},
"text": {
"status": "extensions",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/procedure-method",
"valueCodeableConcept": {
"coding": [
{
"system": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/CodeSystem/mii-cs-onko-strahlentherapie-applikationsart",
"code": "PRCN"
}
]
}
},
{
"url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/StructureDefinition/mii-ex-onko-strahlentherapie-bestrahlung-gesamtdosis",
"valueQuantity": {
"value": 25,
"unit": "Gy"
}
},
{
"url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/StructureDefinition/mii-ex-onko-strahlentherapie-bestrahlung-einzeldosis",
"valueQuantity": {
"value": 2.5,
"unit": "Gy"
}
}
],
"partOf": [
{
"reference": "Procedure/mii-exa-onko-strahlentherapie-pci-sclc"
}
],
"status": "completed",
"category": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "1287742003",
"display": "Radiotherapy (procedure)"
}
]
},
"code": {
"coding": [
{
"system": "http://fhir.de/CodeSystem/bfarm/ops",
"version": "2026",
"code": "8-52"
}
]
},
"subject": {
"reference": "Patient/example"
},
"performedPeriod": {
"start": "2026-05-04",
"end": "2026-05-18"
},
"bodySite": [
{
"coding": [
{
"system": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/CodeSystem/mii-cs-onko-strahlentherapie-zielgebiet",
"code": "1.1",
"display": "Ganzhirn (Neurokranium, inklusive Meningen)"
}
]
}
],
"usedCode": [
{
"coding": [
{
"system": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/CodeSystem/mii-cs-onko-strahlentherapie-strahlenart",
"code": "PN"
}
]
}
]
}