FHIR IG analytics| Package | de.medizininformatikinitiative.kerndatensatz.onkologie |
| Resource Type | ConceptMap |
| Id | ConceptMap-mii-cm-onko-allgemeiner-leistungszustand-ecog-loinc.json |
| FHIR Version | R4 |
| Source | https://medizininformatik-initiative.github.io/kerndatensatzmodul-onkologie/2027.0.0-ballot.1/ConceptMap-mii-cm-onko-allgemeiner-leistungszustand-ecog-loinc.html |
| URL | https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/ConceptMap/mii-cm-onko-allgemeiner-leistungszustand-ecog-loinc |
| Version | 2027.0.0-ballot.1 |
| Status | active |
| Date | 2026-09-15T06:26:59+00:00 |
| Title | Mapping oBDS ECOG zu LOINC |
| Realm | de |
| Description | Mapping der oBDS-Codes für ECOG Performance Status zu LOINC Answer List LL529-9 |
No resources found
| CodeSystem | ||
| kl.dk.fhir.children#2.1.0 | loinc.org | Logical Observation Identifiers, Names and Codes (LOINC) |
| de.medizininformatikinitiative.kerndatensatz.onkologie#2027.0.0-ballot.1 | mii-cs-onko-allgemeiner-leistungszustand-ecog | MII CS Onkologie Allgemeiner Leistungszustand ECOG |
| ValueSet | ||
| de.medizininformatikinitiative.kerndatensatz.onkologie#2027.0.0-ballot.1 | mii-vs-onko-allgemeiner-leistungszustand-ecog | MII VS Onkologie Allgemeiner Leistungszustand nach ECOG |
| de.medizininformatikinitiative.kerndatensatz.onkologie#2027.0.0-ballot.1 | mii-vs-onko-allgemeiner-leistungszustand-ecog-loinc | MII VS Onkologie Allgemeiner Leistungszustand ECOG LOINC |
Note: links and images are rebased to the (stated) source
English
Generated Narrative: ConceptMap mii-cm-onko-allgemeiner-leistungszustand-ecog-loinc
Mapping from MII VS Onkologie Allgemeiner Leistungszustand nach ECOG to MII VS Onkologie Allgemeiner Leistungszustand ECOG LOINC
Mapping from MII CS Onkologie Allgemeiner Leistungszustand ECOG to Logical Observation Identifiers, Names and Codes (LOINC)
| Source Code | Relationship | Target Code | Comment |
| 0 (Normale, uneingeschränkte Aktivität wie vor der Erkrankung (90 - 100 % nach Karnofsky)) | is equivalent to | LA9622-7 (Fully active, able to carry on all pre-disease performance without restriction) | |
| 1 (Einschränkung bei körperlicher Anstrengung, aber gehfähig; leichte körperliche Arbeit bzw. Arbeit im Sitzen (z. B. leichte Hausarbeit oder Büroarbeit) möglich (70 - 80 % nach Karnofsky)) | is equivalent to | LA9623-5 (Restricted in physically strenuous activity but ambulatory and able to carry out work of a light or sedentary nature, e.g., light house work, office work) | |
| 2 (Gehfähig, Selbstversorgung möglich, aber nicht arbeitsfähig; kann mehr als 50 % der Wachzeit aufstehen (50 - 60 % nach Karnofsky)) | is equivalent to | LA9624-3 (Ambulatory and capable of all selfcare but unable to carry out any work activities. Up and about more than 50% of waking hours) | |
| 3 (Nur begrenzte Selbstversorgung möglich; ist 50 % oder mehr der Wachzeit an Bett oder Stuhl gebunden (30 40 % nach Karnofsky)) | is equivalent to | LA9625-0 (Capable of only limited selfcare, confined to bed or chair more than 50% of waking hours) | |
| 4 (Völlig pflegebedürftig, keinerlei Selbstversorgung möglich; völlig an Bett oder Stuhl gebunden (10 - 20 % nach Karnofsky)) | is equivalent to | LA9626-8 (Completely disabled. Cannot carry on any selfcare. Totally confined to bed or chair) | |
| U (Unbekannt) | (not mapped) | No corresponding LOINC code for 'Unknown' available | |
German
Generated Narrative: ConceptMap mii-cm-onko-allgemeiner-leistungszustand-ecog-loinc
Mapping from MII VS Onkologie Allgemeiner Leistungszustand nach ECOG to MII VS Onkologie Allgemeiner Leistungszustand ECOG LOINC
Mapping from MII CS Onkologie Allgemeiner Leistungszustand ECOG to Logical Observation Identifiers, Names and Codes (LOINC)
| Source Code | Relationship | Target Code | Comment |
| 0 (Normale, uneingeschränkte Aktivität wie vor der Erkrankung (90 - 100 % nach Karnofsky)) | is equivalent to | LA9622-7 (Fully active, able to carry on all pre-disease performance without restriction) | |
| 1 (Einschränkung bei körperlicher Anstrengung, aber gehfähig; leichte körperliche Arbeit bzw. Arbeit im Sitzen (z. B. leichte Hausarbeit oder Büroarbeit) möglich (70 - 80 % nach Karnofsky)) | is equivalent to | LA9623-5 (Restricted in physically strenuous activity but ambulatory and able to carry out work of a light or sedentary nature, e.g., light house work, office work) | |
| 2 (Gehfähig, Selbstversorgung möglich, aber nicht arbeitsfähig; kann mehr als 50 % der Wachzeit aufstehen (50 - 60 % nach Karnofsky)) | is equivalent to | LA9624-3 (Ambulatory and capable of all selfcare but unable to carry out any work activities. Up and about more than 50% of waking hours) | |
| 3 (Nur begrenzte Selbstversorgung möglich; ist 50 % oder mehr der Wachzeit an Bett oder Stuhl gebunden (30 40 % nach Karnofsky)) | is equivalent to | LA9625-0 (Capable of only limited selfcare, confined to bed or chair more than 50% of waking hours) | |
| 4 (Völlig pflegebedürftig, keinerlei Selbstversorgung möglich; völlig an Bett oder Stuhl gebunden (10 - 20 % nach Karnofsky)) | is equivalent to | LA9626-8 (Completely disabled. Cannot carry on any selfcare. Totally confined to bed or chair) | |
| U (Unbekannt) | (not mapped) | No corresponding LOINC code for 'Unknown' available | |
{
"resourceType": "ConceptMap",
"id": "mii-cm-onko-allgemeiner-leistungszustand-ecog-loinc",
"meta": {
"extension": [
{
"url": "http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-license",
"valueCode": "CC-BY-4.0"
},
{
"extension": [
{
"url": "packageId",
"valueId": "de.medizininformatikinitiative.kerndatensatz.onkologie"
},
{
"url": "version",
"valueString": "2027.0.0-ballot.1"
},
{
"url": "uri",
"valueUri": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko"
}
],
"url": "http://hl7.org/fhir/StructureDefinition/package-source"
}
],
"profile": [
"http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-shareableconceptmap",
"http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-publishableconceptmap"
]
},
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/cqf-knowledgeCapability",
"valueCode": "shareable"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/cqf-knowledgeCapability",
"valueCode": "publishable"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-versionPolicy",
"valueCodeableConcept": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/artifact-version-policy-codes",
"code": "package",
"display": "Package"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/resource-approvalDate",
"valueDate": "2026-09-15"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-topic",
"valueCodeableConcept": {
"coding": [
{
"system": "http://ncicb.nci.nih.gov/xml/owl/EVS/Thesaurus.owl",
"code": "C3262"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-author",
"valueContactDetail": {
"telecom": [
{
"system": "email",
"value": "thomas.debertshaeuser@charite.de"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-editor",
"valueContactDetail": {
"name": "Taskforce Core Data Set"
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-reviewer",
"valueContactDetail": {
"name": "Interoperability Working Group",
"telecom": [
{
"system": "url",
"value": "https://www.medizininformatik-initiative.de/en/collaboration/interoperability-working-group"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-reviewer",
"valueContactDetail": {
"name": "National Steering Committee",
"telecom": [
{
"system": "url",
"value": "https://www.medizininformatik-initiative.de/en/collaboration/national-steering-committee"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-endorser",
"valueContactDetail": {
"name": "Interoperability Working Group",
"telecom": [
{
"system": "url",
"value": "https://www.medizininformatik-initiative.de/en/collaboration/interoperability-working-group"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-endorser",
"valueContactDetail": {
"name": "National Steering Committee",
"telecom": [
{
"system": "url",
"value": "https://www.medizininformatik-initiative.de/en/collaboration/national-steering-committee"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/artifact-versionAlgorithm",
"valueCoding": {
"system": "http://hl7.org/fhir/version-algorithm",
"code": "semver",
"display": "SemVer"
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/resource-effectivePeriod",
"valuePeriod": {
"start": "2027"
}
}
],
"url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/ConceptMap/mii-cm-onko-allgemeiner-leistungszustand-ecog-loinc",
"version": "2027.0.0-ballot.1",
"title": "Mapping oBDS ECOG zu LOINC",
"status": "active",
"experimental": false,
"date": "2026-09-15T06:26:59+00:00",
"publisher": "Medizininformatik Initiative",
"contact": [
{
"name": "Medizininformatik Initiative",
"telecom": [
{
"system": "url",
"value": "https://www.medizininformatik-initiative.de/"
}
]
}
],
"description": "Mapping der oBDS-Codes für ECOG Performance Status zu LOINC Answer List LL529-9",
"jurisdiction": [
{
"coding": [
{
"system": "urn:iso:std:iso:3166",
"code": "DE",
"display": "Germany"
}
]
}
],
"sourceCanonical": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/ValueSet/mii-vs-onko-allgemeiner-leistungszustand-ecog",
"targetCanonical": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/ValueSet/mii-vs-onko-allgemeiner-leistungszustand-ecog-loinc",
"group": [
{
"source": "https://www.medizininformatik-initiative.de/fhir/ext/modul-onko/CodeSystem/mii-cs-onko-allgemeiner-leistungszustand-ecog",
"target": "http://loinc.org",
"element": [
{
"code": "0",
"display": "Normale, uneingeschränkte Aktivität wie vor der Erkrankung (90 - 100 % nach Karnofsky)",
"target": [
{
"code": "LA9622-7",
"display": "Fully active, able to carry on all pre-disease performance without restriction",
"equivalence": "equivalent"
}
]
},
{
"code": "1",
"display": "Einschränkung bei körperlicher Anstrengung, aber gehfähig; leichte körperliche Arbeit bzw. Arbeit im Sitzen (z. B. leichte Hausarbeit oder Büroarbeit) möglich (70 - 80 % nach Karnofsky)",
"target": [
{
"code": "LA9623-5",
"display": "Restricted in physically strenuous activity but ambulatory and able to carry out work of a light or sedentary nature, e.g., light house work, office work",
"equivalence": "equivalent"
}
]
},
{
"code": "2",
"display": "Gehfähig, Selbstversorgung möglich, aber nicht arbeitsfähig; kann mehr als 50 % der Wachzeit aufstehen (50 - 60 % nach Karnofsky)",
"target": [
{
"code": "LA9624-3",
"display": "Ambulatory and capable of all selfcare but unable to carry out any work activities. Up and about more than 50% of waking hours",
"equivalence": "equivalent"
}
]
},
{
"code": "3",
"display": "Nur begrenzte Selbstversorgung möglich; ist 50 % oder mehr der Wachzeit an Bett oder Stuhl gebunden (30 40 % nach Karnofsky)",
"target": [
{
"code": "LA9625-0",
"display": "Capable of only limited selfcare, confined to bed or chair more than 50% of waking hours",
"equivalence": "equivalent"
}
]
},
{
"code": "4",
"display": "Völlig pflegebedürftig, keinerlei Selbstversorgung möglich; völlig an Bett oder Stuhl gebunden (10 - 20 % nach Karnofsky)",
"target": [
{
"code": "LA9626-8",
"display": "Completely disabled. Cannot carry on any selfcare. Totally confined to bed or chair",
"equivalence": "equivalent"
}
]
},
{
"code": "U",
"display": "Unbekannt",
"target": [
{
"equivalence": "unmatched",
"comment": "No corresponding LOINC code for 'Unknown' available"
}
]
}
]
}
]
}