FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagede.medizininformatikinitiative.kerndatensatz.kardiologie
Resource TypeStructureDefinition
IdStructureDefinition-mii-pr-kardio-kardiale-deviceimplantation.json
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.kardiologie@2026.0.0-alpha.3&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-kardiale-deviceimplantation
URLhttps://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-kardiale-deviceimplantation
Version2026.0.0-alpha.3
Statusactive
Date2025-10-07
NameMII_PR_Kardio_Kardiale_Deviceimplantation
TitleMII PR Kardio Kardiale Deviceimplantation
DescriptionProfil zur Erfassung einer Implantation eines Herzschrittmachers, Kardioverter-Defibrillators oder ventrikulären Unterstützungssystems.
TypeProcedure
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
de.medizininformatikinitiative.kerndatensatz.prozedur#2025.0.1ProcedureMII PR Prozedur Procedure
ValueSet
de.medizininformatikinitiative.kerndatensatz.kardiologie#2026.0.0-alpha.3mii-vs-kardio-kardiale-deviceimplantation-koerperstelle-snomedctMII VS Kardio Kardiale Devicemimplantation Körperstelle [SNOMED CT]
de.medizininformatikinitiative.kerndatensatz.kardiologie#2026.0.0-alpha.3mii-vs-kardio-kardiale-deviceimplantation-opsMII VS Kardio Kardiale Devicemimplantation [OPS]
de.medizininformatikinitiative.kerndatensatz.kardiologie#2026.0.0-alpha.3mii-vs-kardio-kardiale-deviceimplantation-scnomedctMII VS Kardio Kardiale Devicemimplantation [SNOMED CT]

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "id": "mii-pr-kardio-kardiale-deviceimplantation",
  "extension": [
    {
      "url": "https://www.medizininformatik-initiative.de/fhir/modul-meta/StructureDefinition/mii-ex-meta-license-codeable",
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/spdx-license",
            "code": "CC-BY-4.0",
            "display": "Creative Commons Attribution 4.0 International"
          }
        ]
      }
    }
  ],
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-kardiale-deviceimplantation",
  "version": "2026.0.0-alpha.3",
  "name": "MII_PR_Kardio_Kardiale_Deviceimplantation",
  "title": "MII PR Kardio Kardiale Deviceimplantation",
  "status": "active",
  "experimental": false,
  "date": "2025-10-07",
  "publisher": "Medizininformatik Initiative",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "https://www.medizininformatik-initiative.de"
        }
      ]
    }
  ],
  "description": "Profil zur Erfassung einer Implantation eines Herzschrittmachers, Kardioverter-Defibrillators oder ventrikulären Unterstützungssystems.",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Procedure",
  "baseDefinition": "https://www.medizininformatik-initiative.de/fhir/core/modul-prozedur/StructureDefinition/Procedure",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Procedure.code",
        "path": "Procedure.code",
        "comment": "Hier sollen mindestens ein SNOMED- oder ein OPS-Code angegeben werden.\r\nFür ACRIBiS eignen sich die folgenden Codes (Stand 01.05.2025):\r\n - **ICD**: 395218007 - Implantation of internal cardiac defibrillator (procedure)\r\n - **CRT**: 429064006 - Implantation of cardiac resynchronization therapy implantable pacemaker (procedure)\r\n - **ICD+CRT**: 1236755008 - Implantation of cardiac resynchronization defibrillator system (procedure)\r\n - **LVAD**: 232967006 - Implantation of left cardiac ventricular assist device (procedure)\r\n - **RVAD**: 232966002 - Implantation of right cardiac ventricular assist device (procedure)\r\n - **BiVAD**: 232968001 - Implantation of cardiac biventricular assist device (procedure)"
      },
      {
        "id": "Procedure.code.coding",
        "path": "Procedure.code.coding",
        "slicing": {
          "discriminator": [
            {
              "type": "pattern",
              "path": "$this"
            }
          ],
          "rules": "closed"
        }
      },
      {
        "id": "Procedure.code.coding.system",
        "path": "Procedure.code.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Procedure.code.coding.version",
        "path": "Procedure.code.coding.version",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Procedure.code.coding.code",
        "path": "Procedure.code.coding.code",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Procedure.code.coding:ops",
        "path": "Procedure.code.coding",
        "sliceName": "ops",
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/ValueSet/mii-vs-kardio-kardiale-deviceimplantation-ops"
        }
      },
      {
        "id": "Procedure.code.coding:sct",
        "path": "Procedure.code.coding",
        "sliceName": "sct",
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/ValueSet/mii-vs-kardio-kardiale-deviceimplantation-scnomedct"
        }
      },
      {
        "id": "Procedure.code.coding:sct.version",
        "path": "Procedure.code.coding.version",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Procedure.subject",
        "path": "Procedure.subject",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://hl7.org/fhir/StructureDefinition/Patient"
            ]
          }
        ]
      },
      {
        "id": "Procedure.bodySite",
        "path": "Procedure.bodySite",
        "comment": "Hier soll mindestens ein SNOMED-Code angegeben werden.\r\nFür ACRIBiS müssen die folgenden Codes verwendet werden (Stand 01.05.2025):\r\n - **Herzschrittmacher/Implantierter Defibrillator**: 80891009 - Heart structure (body structure)\r\n - **LVAD**: 87878005 - Left cardiac ventricular structure (body structure)\r\n - **RVAD**: 53085002 - Right cardiac ventricular structure (body structure)\r\n - **BiVAD**: 87878005 - Left cardiac ventricular structure (body structure) **und** 53085002 - Right cardiac ventricular structure (body structure)\r\n",
        "min": 1,
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/ValueSet/mii-vs-kardio-kardiale-deviceimplantation-koerperstelle-snomedct"
        }
      },
      {
        "id": "Procedure.bodySite.coding",
        "path": "Procedure.bodySite.coding",
        "min": 1
      },
      {
        "id": "Procedure.bodySite.coding.version",
        "path": "Procedure.bodySite.coding.version",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Procedure.bodySite.coding:snomed-ct",
        "path": "Procedure.bodySite.coding",
        "sliceName": "snomed-ct",
        "min": 1
      },
      {
        "id": "Procedure.bodySite.coding:snomed-ct.version",
        "path": "Procedure.bodySite.coding.version",
        "min": 1
      },
      {
        "id": "Procedure.focalDevice",
        "path": "Procedure.focalDevice",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Procedure.focalDevice.manipulated",
        "path": "Procedure.focalDevice.manipulated",
        "mustSupport": true
      }
    ]
  }
}