FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagede.medizininformatikinitiative.kerndatensatz.kardiologie
Resource TypeStructureDefinition
IdStructureDefinition-mii-pr-kardio-ekg-geraet.json
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.kardiologie@2026.0.0-alpha.3&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-ekg-geraet
URLhttps://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-ekg-geraet
Version2026.0.0-alpha.3
Statusdraft
Date2025-05-22
NameMII_PR_Kardio_EKG_Geraet
TitleMII PR Kardio EKG Gerät
DescriptionProfil zur Abbildung eines EKG-Gerätes.
TypeDevice
Kindresource

Resources that use this resource

StructureDefinition
de.medizininformatikinitiative.kerndatensatz.kardiologie#2026.0.0-alpha.3mii-pr-kardio-ekg-kanalMII PR Kardio EKG Kanal

Resources that this resource uses

ValueSet
de.medizininformatikinitiative.kerndatensatz.kardiologie#2026.0.0-alpha.3mii-vs-kardio-objekte-geraete-mdcMII VS Kardio MDC Objects Devices [MDC]

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "id": "mii-pr-kardio-ekg-geraet",
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/StructureDefinition/mii-pr-kardio-ekg-geraet",
  "version": "2026.0.0-alpha.3",
  "name": "MII_PR_Kardio_EKG_Geraet",
  "title": "MII PR Kardio EKG Gerät",
  "status": "draft",
  "experimental": true,
  "date": "2025-05-22",
  "publisher": "Medizininformatik Initiative",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "https://www.medizininformatik-initiative.de"
        }
      ]
    }
  ],
  "description": "Profil zur Abbildung eines EKG-Gerätes.",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Device",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Device",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Device.status",
        "path": "Device.status",
        "mustSupport": true
      },
      {
        "id": "Device.manufacturer",
        "path": "Device.manufacturer",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Device.deviceName",
        "path": "Device.deviceName",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Device.type",
        "path": "Device.type",
        "min": 1,
        "mustSupport": true,
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-kardio/ValueSet/mii-vs-kardio-objekte-geraete-mdc"
        }
      },
      {
        "id": "Device.type.coding",
        "path": "Device.type.coding",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Device.type.coding.system",
        "path": "Device.type.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Device.type.coding.version",
        "path": "Device.type.coding.version",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Device.type.coding.code",
        "path": "Device.type.coding.code",
        "min": 1,
        "mustSupport": true
      }
    ]
  }
}