FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagede.medizininformatikinitiative.kerndatensatz.icu
Resource TypeStructureDefinition
Idmii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung.json
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.icu@2026.0.0&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-devicemetric-eingestellte-gemessene-parameter-beatmung
URLhttps://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-devicemetric-eingestellte-gemessene-parameter-beatmung
Version2026.0.0
Statusactive
NameMII_PR_ICU_VENT_Devicemetric_Eingestellte_Gemessene_Parameter_Beatmung
TitleMII PR ICU VENT DeviceMetric Eingestellte Gemessene Parameter Beatmung
Realmde
TypeDeviceMetric
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

ValueSet
mii-vs-icu-category-procedure-beatmung-snomedMII VS ICU Category Procedure Beatmung SNOMED

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "id": "mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung",
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-devicemetric-eingestellte-gemessene-parameter-beatmung",
  "version": "2026.0.0",
  "name": "MII_PR_ICU_VENT_Devicemetric_Eingestellte_Gemessene_Parameter_Beatmung",
  "title": "MII PR ICU VENT DeviceMetric Eingestellte Gemessene Parameter Beatmung",
  "status": "active",
  "publisher": "Medizininformatik Initiative",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "https://www.medizininformatik-initiative.de"
        }
      ]
    }
  ],
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "DeviceMetric",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "DeviceMetric.type",
        "path": "DeviceMetric.type",
        "mustSupport": true,
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/mii-vs-icu-category-procedure-beatmung-snomed"
        }
      },
      {
        "id": "DeviceMetric.type.coding",
        "path": "DeviceMetric.type.coding",
        "patternCoding": {
          "system": "http://snomed.info/sct"
        },
        "mustSupport": true
      },
      {
        "id": "DeviceMetric.type.coding.system",
        "path": "DeviceMetric.type.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "DeviceMetric.type.coding.code",
        "path": "DeviceMetric.type.coding.code",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "DeviceMetric.source",
        "path": "DeviceMetric.source",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/icu-device"
            ]
          }
        ],
        "mustSupport": true
      },
      {
        "id": "DeviceMetric.category",
        "path": "DeviceMetric.category",
        "mustSupport": true
      }
    ]
  }
}