FHIR IG analytics| Package | de.medizininformatikinitiative.kerndatensatz.icu |
| Resource Type | StructureDefinition |
| Id | mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung.json |
| FHIR Version | R4 |
| Source | https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.icu@2026.0.0&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-devicemetric-eingestellte-gemessene-parameter-beatmung |
| URL | https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-devicemetric-eingestellte-gemessene-parameter-beatmung |
| Version | 2026.0.0 |
| Status | active |
| Name | MII_PR_ICU_VENT_Devicemetric_Eingestellte_Gemessene_Parameter_Beatmung |
| Title | MII PR ICU VENT DeviceMetric Eingestellte Gemessene Parameter Beatmung |
| Realm | de |
| Type | DeviceMetric |
| Kind | resource |
No resources found
| ValueSet | |
| mii-vs-icu-category-procedure-beatmung-snomed | MII VS ICU Category Procedure Beatmung SNOMED |
No narrative content found in resource
{
"resourceType": "StructureDefinition",
"id": "mii-pr-icu-vent-dm-eingestellte-gemessene-parameter-beatmung",
"url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-devicemetric-eingestellte-gemessene-parameter-beatmung",
"version": "2026.0.0",
"name": "MII_PR_ICU_VENT_Devicemetric_Eingestellte_Gemessene_Parameter_Beatmung",
"title": "MII PR ICU VENT DeviceMetric Eingestellte Gemessene Parameter Beatmung",
"status": "active",
"publisher": "Medizininformatik Initiative",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "https://www.medizininformatik-initiative.de"
}
]
}
],
"fhirVersion": "4.0.1",
"kind": "resource",
"abstract": false,
"type": "DeviceMetric",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "DeviceMetric.type",
"path": "DeviceMetric.type",
"mustSupport": true,
"binding": {
"strength": "required",
"valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/mii-vs-icu-category-procedure-beatmung-snomed"
}
},
{
"id": "DeviceMetric.type.coding",
"path": "DeviceMetric.type.coding",
"patternCoding": {
"system": "http://snomed.info/sct"
},
"mustSupport": true
},
{
"id": "DeviceMetric.type.coding.system",
"path": "DeviceMetric.type.coding.system",
"min": 1,
"mustSupport": true
},
{
"id": "DeviceMetric.type.coding.code",
"path": "DeviceMetric.type.coding.code",
"min": 1,
"mustSupport": true
},
{
"id": "DeviceMetric.source",
"path": "DeviceMetric.source",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/icu-device"
]
}
],
"mustSupport": true
},
{
"id": "DeviceMetric.category",
"path": "DeviceMetric.category",
"mustSupport": true
}
]
}
}