FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagede.medizininformatikinitiative.kerndatensatz.icu
Resource TypeStructureDefinition
Idmii-pr-icu-vent-beatmungszeit-hohem-druck.json
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.icu@2026.0.0&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-beatmungszeit-hohem-druck
URLhttps://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-beatmungszeit-hohem-druck
Version2026.0.0
Statusactive
NameMII_PR_ICU_VENT_Beatmungszeit_Hohem_Druck
TitleMII PR ICU VENT Beatmungszeit Hohem Druck
Realmde
TypeObservation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
mii-pr-icu-vent-parameter-von-beatmungMII PR ICU VENT Parameter von Beatmung

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "id": "mii-pr-icu-vent-beatmungszeit-hohem-druck",
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-beatmungszeit-hohem-druck",
  "version": "2026.0.0",
  "name": "MII_PR_ICU_VENT_Beatmungszeit_Hohem_Druck",
  "title": "MII PR ICU VENT Beatmungszeit Hohem Druck",
  "status": "active",
  "publisher": "Medizininformatik Initiative",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "https://www.medizininformatik-initiative.de"
        }
      ]
    }
  ],
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-vent-parameter-von-beatmung",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.code.coding",
        "path": "Observation.code.coding",
        "min": 2
      },
      {
        "id": "Observation.code.coding:sct",
        "path": "Observation.code.coding",
        "sliceName": "sct",
        "max": "0",
        "patternCoding": {
          "system": "http://snomed.info/sct"
        }
      },
      {
        "id": "Observation.code.coding:loinc",
        "path": "Observation.code.coding",
        "sliceName": "loinc",
        "min": 1,
        "max": "1",
        "patternCoding": {
          "system": "http://loinc.org",
          "code": "76190-8"
        }
      },
      {
        "id": "Observation.code.coding:IEEE-11073",
        "path": "Observation.code.coding",
        "sliceName": "IEEE-11073",
        "min": 1,
        "max": "1",
        "patternCoding": {
          "system": "urn:iso:std:iso:11073:10101",
          "code": "16929860"
        }
      },
      {
        "id": "Observation.effective[x]",
        "path": "Observation.effective[x]",
        "min": 1
      },
      {
        "id": "Observation.value[x]",
        "path": "Observation.value[x]",
        "slicing": {
          "discriminator": [
            {
              "type": "type",
              "path": "$this"
            }
          ],
          "ordered": false,
          "rules": "open"
        }
      },
      {
        "id": "Observation.value[x]:valueQuantity",
        "path": "Observation.value[x]",
        "sliceName": "valueQuantity",
        "patternQuantity": {
          "system": "http://unitsofmeasure.org",
          "code": "s"
        }
      }
    ]
  }
}