FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/sd-mii-icu-bilanz

Packagede.medizininformatikinitiative.kerndatensatz.icu
TypeStructureDefinition
Idsd-mii-icu-bilanz
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.icu@2025.0.4&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/bilanz
URLhttps://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/bilanz
Version2025.0.4
Statusactive
NameSD_MII_ICU_Bilanz
TitleSD MII ICU Bilanz
TypeObservation
Kindresource

Resources that use this resource

StructureDefinition
bilanz-abnahme-haemofiltration-einzelmesswerteSD MII ICU Bilanz Abnahme Haemofiltration Einzelmesswerte
bilanz-ausfuhr-drainage-generischSD MII ICU Bilanz Ausfuhr Drainage Generisch
bilanz-ausfuhr-drainage-opSD MII ICU Bilanz Ausfuhr Drainage OP
bilanz-ausfuhr-drainage-wundSD MII ICU Bilanz Ausfuhr Drainage Wund
bilanz-ausfuhr-fluessigkeit-gesamtSD MII ICU Bilanz Ausfuhr Fluessigkeit Gesamt
bilanz-ausfuhr-gallenfluessigkeitSD MII ICU Bilanz Ausfuhr Gallenfluessigkeit
bilanz-ausfuhr-gallengangSD MII ICU Bilanz Ausfuhr Gallengang
bilanz-ausfuhr-magensondeSD MII ICU Bilanz Ausfuhr Magensonde
bilanz-ausfuhr-opdrainageSD MII ICU Bilanz Ausfuhr Opdrainage
bilanz-ausfuhr-pankreasdrainageSD MII ICU Bilanz Ausfuhr Pankreasdrainage
bilanz-ausfuhr-stuhlgangSD MII ICU Bilanz Ausfuhr Stuhlgang
bilanz-ausfuhr-urinSD MII ICU Bilanz Ausfuhr Urin
bilanz-ausfuhr-wunddrainageSD MII ICU Bilanz Ausfuhr Wunddrainage
bilanz-blutverlustSD MII ICU Bilanz Blutverlust
bilanz-einfuhr-enterale-fluesseSD MII ICU Bilanz Einfuhr Enterale Fluesse
bilanz-einfuhr-enterale-fluessigkeitSD MII ICU Bilanz Einfuhr Enterale Fluessigkeit
bilanz-einfuhr-fluessigkeit-gesamtSD MII ICU Bilanz Einfuhr Fluessigkeit Gesamt
bilanz-einfuhr-oraler-fluesseSD MII ICU Bilanz Einfuhr Oraler Fluesse
bilanz-einfuhr-oraler-fluessigkeitSD MII ICU Bilanz Einfuhr Oraler Fluessigkeit
bilanz-gesamte-ausfuhrSD MII ICU Bilanz Gesamte Ausfuhr
bilanz-gesamte-einfuhrSD MII ICU Bilanz Gesamte Einfuhr
bilanz-gesamte-tages-bilanzSD MII ICU Bilanz Gesamte Tages Bilanz

Resources that this resource uses

ValueSet
vs-mii-icu-category-observation-bilanzen-hl7VS MII ICU Category Observation Bilanzen [HL7]
vs-mii-icu-code-observation-bilanzen-iso11073VS MII ICU Code Observation Bilanzen [ISO11073]
vs-mii-icu-code-observation-bilanzen-loincVS MII ICU Code Observation Bilanzen [LOINC]
vs-mii-icu-code-observation-bilanzen-snomedVS MII ICU Code Observation Bilanzen [SNOMED]

Narrative

Note: links and images are rebased to the (stated) source

No human-readable text provided in this case.

Source

{
  "resourceType": "StructureDefinition",
  "id": "sd-mii-icu-bilanz",
  "text": {
    "status": "empty",
    "div": "<!-- snip (see above) -->"
  },
  "url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/bilanz",
  "version": "2025.0.4",
  "name": "SD_MII_ICU_Bilanz",
  "title": "SD MII ICU Bilanz",
  "status": "active",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.identifier",
        "path": "Observation.identifier",
        "mustSupport": true
      },
      {
        "id": "Observation.category",
        "path": "Observation.category",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.category.coding",
        "path": "Observation.category.coding",
        "slicing": {
          "discriminator": [
            {
              "type": "pattern",
              "path": "$this"
            }
          ],
          "rules": "open"
        },
        "min": 2,
        "mustSupport": true
      },
      {
        "id": "Observation.category.coding:hl7-category",
        "path": "Observation.category.coding",
        "sliceName": "hl7-category",
        "max": "1",
        "patternCoding": {
          "system": "http://terminology.hl7.org/CodeSystem/observation-category"
        },
        "mustSupport": true,
        "binding": {
          "strength": "required",
          "description": "A Code of the following value set is required. Only relevant codes for balances should be vital-signs, exam and therapy.",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/vs-mii-icu-category-observation-bilanzen-hl7"
        }
      },
      {
        "id": "Observation.category.coding:hl7-category.system",
        "path": "Observation.category.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.category.coding:hl7-category.code",
        "path": "Observation.category.coding.code",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.category.coding:kdsicu-category",
        "path": "Observation.category.coding",
        "sliceName": "kdsicu-category",
        "min": 1,
        "max": "1",
        "patternCoding": {
          "system": "http://snomed.info/sct",
          "code": "364396009"
        },
        "mustSupport": true
      },
      {
        "id": "Observation.category.coding:kdsicu-category.system",
        "path": "Observation.category.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.category.coding:kdsicu-category.code",
        "path": "Observation.category.coding.code",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.code",
        "path": "Observation.code",
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding",
        "path": "Observation.code.coding",
        "slicing": {
          "discriminator": [
            {
              "type": "pattern",
              "path": "$this"
            }
          ],
          "rules": "closed"
        },
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:sct",
        "path": "Observation.code.coding",
        "sliceName": "sct",
        "min": 1,
        "max": "1",
        "patternCoding": {
          "system": "http://snomed.info/sct"
        },
        "mustSupport": true,
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/vs-mii-icu-code-observation-bilanzen-snomed"
        }
      },
      {
        "id": "Observation.code.coding:sct.system",
        "path": "Observation.code.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:sct.code",
        "path": "Observation.code.coding.code",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:sct.display",
        "path": "Observation.code.coding.display",
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:loinc",
        "path": "Observation.code.coding",
        "sliceName": "loinc",
        "patternCoding": {
          "system": "http://loinc.org"
        },
        "mustSupport": true,
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/vs-mii-icu-code-observation-bilanzen-loinc"
        }
      },
      {
        "id": "Observation.code.coding:loinc.system",
        "path": "Observation.code.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:loinc.code",
        "path": "Observation.code.coding.code",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:loinc.display",
        "path": "Observation.code.coding.display",
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:IEEE-11073",
        "path": "Observation.code.coding",
        "sliceName": "IEEE-11073",
        "patternCoding": {
          "system": "urn:iso:std:iso:11073:10101"
        },
        "mustSupport": true,
        "binding": {
          "strength": "required",
          "valueSet": "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/vs-mii-icu-code-observation-bilanzen-iso11073"
        }
      },
      {
        "id": "Observation.code.coding:IEEE-11073.system",
        "path": "Observation.code.coding.system",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.code.coding:IEEE-11073.code",
        "path": "Observation.code.coding.code",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.subject",
        "path": "Observation.subject",
        "min": 1,
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://hl7.org/fhir/StructureDefinition/Patient"
            ]
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.encounter",
        "path": "Observation.encounter",
        "mustSupport": true
      },
      {
        "id": "Observation.effective[x]",
        "path": "Observation.effective[x]",
        "min": 1,
        "type": [
          {
            "code": "dateTime"
          },
          {
            "code": "Period"
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.issued",
        "path": "Observation.issued",
        "mustSupport": true
      },
      {
        "id": "Observation.value[x]",
        "path": "Observation.value[x]",
        "min": 1,
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.dataAbsentReason",
        "path": "Observation.dataAbsentReason",
        "mustSupport": true
      },
      {
        "id": "Observation.interpretation",
        "path": "Observation.interpretation",
        "mustSupport": true
      },
      {
        "id": "Observation.bodySite",
        "path": "Observation.bodySite",
        "mustSupport": true
      },
      {
        "id": "Observation.method",
        "path": "Observation.method",
        "mustSupport": true
      },
      {
        "id": "Observation.specimen",
        "path": "Observation.specimen",
        "mustSupport": true
      },
      {
        "id": "Observation.device",
        "path": "Observation.device",
        "mustSupport": true
      },
      {
        "id": "Observation.referenceRange",
        "path": "Observation.referenceRange",
        "mustSupport": true
      }
    ]
  }
}