FHIR © HL7.org  |  Server Home  |  XIG Home  |  XIG Stats  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck

Packagede.gematik.isik
Resource TypeStructureDefinition
Idsd-mii-icu-rechtsventrikulaerer-druck
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.gematik.isik@5.0.0&canonical=https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck
URLhttps://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck
Version5.0.0
Statusactive
Date2025-06-26
NameSD_MII_ICU_Rechtsventrikulaerer_Druck
TitleSD MII ICU Rechtsventrikulaerer Druck
Realmde
Authorityhl7
TypeObservation
Kindresource

Resources that use this resource

CapabilityStatement
ISiKCapabilityStatementVitalSignICUSourceExtendedRolleISiK CapabilityStatement VitalSign ICU Source Extended

Resources that this resource uses

StructureDefinition
sd-mii-icu-sonstige-pulsatile-druecke-generischSD MII ICU Sonstige pulsatile Druecke Generisch

Narrative

No narrative content found in resource


Source

{
  "resourceType": "StructureDefinition",
  "id": "sd-mii-icu-rechtsventrikulaerer-druck",
  "url": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck",
  "version": "5.0.0",
  "name": "SD_MII_ICU_Rechtsventrikulaerer_Druck",
  "title": "SD MII ICU Rechtsventrikulaerer Druck",
  "status": "active",
  "experimental": false,
  "date": "2025-06-26",
  "publisher": "gematik GmbH",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.category",
        "path": "Observation.category",
        "patternCodeableConcept": {
          "coding": [
            {
              "code": "vital-signs",
              "system": "http://terminology.hl7.org/CodeSystem/observation-category"
            }
          ]
        }
      },
      {
        "id": "Observation.code.coding",
        "path": "Observation.code.coding",
        "min": 3,
        "max": "3"
      },
      {
        "id": "Observation.code.coding:sct",
        "path": "Observation.code.coding",
        "sliceName": "sct",
        "patternCoding": {
          "code": "276756009",
          "system": "http://snomed.info/sct"
        }
      },
      {
        "id": "Observation.code.coding:IEEE-11073",
        "path": "Observation.code.coding",
        "sliceName": "IEEE-11073",
        "min": 1,
        "max": "1",
        "patternCoding": {
          "code": "150104",
          "system": "urn:iso:std:iso:11073:10101"
        }
      },
      {
        "id": "Observation.bodySite",
        "path": "Observation.bodySite",
        "patternCodeableConcept": {
          "coding": [
            {
              "code": "53085002",
              "system": "http://snomed.info/sct"
            }
          ]
        }
      },
      {
        "id": "Observation.component:SystolicBP",
        "path": "Observation.component",
        "sliceName": "SystolicBP"
      },
      {
        "id": "Observation.component:SystolicBP.code.coding:IEEE-11073",
        "path": "Observation.component.code.coding",
        "sliceName": "IEEE-11073",
        "patternCoding": {
          "code": "150105",
          "system": "urn:iso:std:iso:11073:10101"
        }
      },
      {
        "id": "Observation.component:SystolicBP.code.coding:loinc-detailed",
        "path": "Observation.component.code.coding",
        "sliceName": "loinc-detailed",
        "min": 0,
        "max": "1",
        "patternCoding": {
          "code": "8432-7",
          "system": "http://loinc.org"
        }
      },
      {
        "id": "Observation.component:SystolicBP.code.coding:sct-detailed",
        "path": "Observation.component.code.coding",
        "sliceName": "sct-detailed",
        "min": 0,
        "max": "*",
        "patternCoding": {
          "code": "276772001",
          "system": "http://snomed.info/sct"
        }
      },
      {
        "id": "Observation.component:DiastolicBP",
        "path": "Observation.component",
        "sliceName": "DiastolicBP"
      },
      {
        "id": "Observation.component:DiastolicBP.code.coding:IEEE-11073",
        "path": "Observation.component.code.coding",
        "sliceName": "IEEE-11073",
        "patternCoding": {
          "code": "150106",
          "system": "urn:iso:std:iso:11073:10101"
        }
      },
      {
        "id": "Observation.component:DiastolicBP.code.coding:loinc-detailed",
        "path": "Observation.component.code.coding",
        "sliceName": "loinc-detailed",
        "min": 0,
        "max": "1",
        "patternCoding": {
          "code": "8377-4",
          "system": "http://loinc.org"
        }
      },
      {
        "id": "Observation.component:DiastolicBP.code.coding:sct-detailed",
        "path": "Observation.component.code.coding",
        "sliceName": "sct-detailed",
        "min": 0,
        "max": "*",
        "patternCoding": {
          "code": "276773006",
          "system": "http://snomed.info/sct"
        }
      },
      {
        "id": "Observation.component:meanBP",
        "path": "Observation.component",
        "sliceName": "meanBP"
      },
      {
        "id": "Observation.component:meanBP.code.coding:IEEE-11073",
        "path": "Observation.component.code.coding",
        "sliceName": "IEEE-11073",
        "patternCoding": {
          "code": "150107",
          "system": "urn:iso:std:iso:11073:10101"
        }
      },
      {
        "id": "Observation.component:meanBP.code.coding:loinc-detailed",
        "path": "Observation.component.code.coding",
        "sliceName": "loinc-detailed",
        "min": 0,
        "max": "1",
        "patternCoding": {
          "code": "8406-1",
          "system": "http://loinc.org"
        }
      }
    ]
  }
}