FHIR © HL7.org  |  Server Home  |  XIG Home  |  XIG Stats  |  Server Source  |  FHIR  

FHIR IG Statistics: ValueSet/gecco-valueset-blood-gas-analysis-combined-v105

Packagede.gecco
Resource TypeValueSet
Idgecco-valueset-blood-gas-analysis-combined-v105
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.gecco@1.0.5&canonical=https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-combined
URLhttps://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-combined
Version1.0.5
Statusdraft
Date2021-10-01T00:00:00.000Z
NameBloodGasAnalysisCombined
TitleBlood Gas Analysis Combined
DescriptionRelevant codes for a blood gas analysis taken from LOINC and SNOMED CT.
CopyrightThis artefact includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/getsnomed-ct or info@snomed.org.

Resources that use this resource

No resources found


Resources that this resource uses

CodeSystem
loinc.orgLogical Observation Identifiers, Names and Codes (LOINC)
sctSNOMED CT International Edition

Narrative

Note: links and images are rebased to the (stated) source

Blood Gas Analysis Combined

https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-combined

Relevant codes for a blood gas analysis taken from LOINC and SNOMED CT.


Source

{
  "resourceType": "ValueSet",
  "id": "gecco-valueset-blood-gas-analysis-combined-v105",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/shareablevalueset"
    ]
  },
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "url": "https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/blood-gas-analysis-combined",
  "name": "BloodGasAnalysisCombined",
  "title": "Blood Gas Analysis Combined",
  "status": "draft",
  "compose": {
    "include": [
      {
        "concept": [
          {
            "code": "11558-4",
            "display": "pH of Blood"
          },
          {
            "code": "2744-1",
            "display": "pH of Arterial blood"
          },
          {
            "code": "2745-8",
            "display": "pH of Capillary blood"
          },
          {
            "code": "3150-0",
            "display": "Inhaled oxygen concentration"
          },
          {
            "code": "11556-8",
            "display": "Oxygen [Partial pressure] in Blood"
          },
          {
            "code": "2703-7",
            "display": "Oxygen [Partial pressure] in Arterial blood"
          },
          {
            "code": "2704-5",
            "display": "Oxygen [Partial pressure] in Capillary blood"
          },
          {
            "code": "11557-6",
            "display": "Carbon dioxide [Partial pressure] in Blood"
          },
          {
            "code": "2020-6",
            "display": "Carbon dioxide [Partial pressure] in Capillary blood"
          },
          {
            "code": "2019-8",
            "display": "Carbon dioxide [Partial pressure] in Arterial blood"
          },
          {
            "code": "2708-6",
            "display": "Oxygen saturation in Arterial blood"
          }
        ],
        "system": "http://loinc.org"
      },
      {
        "concept": [
          {
            "code": "250774007",
            "display": "Inspired oxygen concentration"
          },
          {
            "code": "431314004",
            "display": "Peripheral oxygen saturation"
          }
        ],
        "system": "http://snomed.info/sct"
      }
    ]
  },
  "version": "1.0.5",
  "description": "Relevant codes for a blood gas analysis taken from LOINC and SNOMED CT.",
  "date": "2021-10-01T00:00:00.000Z",
  "experimental": false,
  "publisher": "UKSH Lübeck",
  "copyright": "This artefact includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/getsnomed-ct or info@snomed.org."
}