| Package | de.gecco |
| Resource Type | StructureDefinition |
| Id | gecco-observation-blood-pressure |
| FHIR Version | R4 |
| Source | https://simplifier.net/resolve?scope=de.gecco@1.0.5&canonical=https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure |
| URL | https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure |
| Version | 1.0.4 |
| Status | active |
| Date | 2021-05-17 |
| Name | BloodPressure |
| Title | Blood Pressure |
| Description | The blood pressure of a patient. |
| Type | Observation |
| Kind | resource |
No resources found
| StructureDefinition | |
| vital-signs-base | Vital Signs Base Profile |
No narrative content found in resource
{
"resourceType": "StructureDefinition",
"id": "gecco-observation-blood-pressure",
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-category",
"valueString": "Clinical.Diagnostics"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-security-category",
"valueCode": "patient"
}
],
"url": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure",
"version": "1.0.4",
"name": "BloodPressure",
"title": "Blood Pressure",
"status": "active",
"date": "2021-05-17",
"publisher": "Charité",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "https://www.bihealth.org/en/research/core-facilities/interoperability/"
}
]
}
],
"description": "The blood pressure of a patient.",
"fhirVersion": "4.0.1",
"mapping": [
{
"identity": "workflow",
"uri": "http://hl7.org/fhir/workflow",
"name": "Workflow Pattern"
},
{
"identity": "sct-concept",
"uri": "http://snomed.info/conceptdomain",
"name": "SNOMED CT Concept Domain Binding"
},
{
"identity": "v2",
"uri": "http://hl7.org/v2",
"name": "HL7 v2 Mapping"
},
{
"identity": "rim",
"uri": "http://hl7.org/v3",
"name": "RIM Mapping"
},
{
"identity": "w5",
"uri": "http://hl7.org/fhir/fivews",
"name": "FiveWs Pattern Mapping"
},
{
"identity": "sct-attr",
"uri": "http://snomed.org/attributebinding",
"name": "SNOMED CT Attribute Binding"
}
],
"kind": "resource",
"abstract": false,
"type": "Observation",
"baseDefinition": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/vital-signs-base",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "Observation.code.coding",
"path": "Observation.code.coding",
"slicing": {
"discriminator": [
{
"type": "pattern",
"path": "$this"
}
],
"rules": "open"
},
"min": 1
},
{
"id": "Observation.code.coding:loinc",
"path": "Observation.code.coding",
"sliceName": "loinc",
"min": 1,
"max": "*",
"patternCoding": {
"system": "http://loinc.org",
"code": "85354-9"
}
},
{
"id": "Observation.code.coding:loinc.system",
"path": "Observation.code.coding.system",
"min": 1
},
{
"id": "Observation.code.coding:loinc.code",
"path": "Observation.code.coding.code",
"min": 1
},
{
"id": "Observation.code.coding:snomed",
"path": "Observation.code.coding",
"sliceName": "snomed",
"min": 0,
"max": "*",
"patternCoding": {
"system": "http://snomed.info/sct",
"code": "75367002"
}
},
{
"id": "Observation.code.coding:snomed.system",
"path": "Observation.code.coding.system",
"min": 1
},
{
"id": "Observation.code.coding:snomed.code",
"path": "Observation.code.coding.code",
"min": 1
},
{
"id": "Observation.value[x]",
"path": "Observation.value[x]",
"max": "0"
},
{
"id": "Observation.component",
"path": "Observation.component",
"slicing": {
"discriminator": [
{
"type": "pattern",
"path": "code"
}
],
"rules": "open"
},
"short": "Used when reporting systolic and diastolic blood pressure.",
"definition": "Used when reporting systolic and diastolic blood pressure.",
"min": 2,
"constraint": [
{
"key": "vs-3",
"severity": "error",
"human": "If there is no a value a data absent reason must be present",
"expression": "value.exists() or dataAbsentReason.exists()",
"xpath": "f:*[starts-with(local-name(.), 'value')] or f:dataAbsentReason",
"source": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure"
}
],
"mustSupport": true
},
{
"id": "Observation.component:systolicBloodPressure",
"path": "Observation.component",
"sliceName": "systolicBloodPressure",
"short": "Systolic blood pressure",
"min": 1,
"max": "1",
"mustSupport": true
},
{
"id": "Observation.component:systolicBloodPressure.code",
"path": "Observation.component.code",
"patternCodeableConcept": {
"coding": [
{
"system": "http://loinc.org",
"code": "8480-6"
}
]
},
"mustSupport": true
},
{
"id": "Observation.component:systolicBloodPressure.code.coding",
"path": "Observation.component.code.coding",
"slicing": {
"discriminator": [
{
"type": "pattern",
"path": "$this"
}
],
"rules": "open"
},
"min": 1
},
{
"id": "Observation.component:systolicBloodPressure.code.coding:loinc",
"path": "Observation.component.code.coding",
"sliceName": "loinc",
"min": 1,
"max": "*",
"patternCoding": {
"system": "http://loinc.org",
"code": "8480-6"
}
},
{
"id": "Observation.component:systolicBloodPressure.code.coding:loinc.system",
"path": "Observation.component.code.coding.system",
"min": 1
},
{
"id": "Observation.component:systolicBloodPressure.code.coding:loinc.code",
"path": "Observation.component.code.coding.code",
"min": 1
},
{
"id": "Observation.component:systolicBloodPressure.code.coding:snomed",
"path": "Observation.component.code.coding",
"sliceName": "snomed",
"min": 0,
"max": "*",
"patternCoding": {
"system": "http://snomed.info/sct",
"code": "271649006"
}
},
{
"id": "Observation.component:systolicBloodPressure.code.coding:snomed.system",
"path": "Observation.component.code.coding.system",
"min": 1
},
{
"id": "Observation.component:systolicBloodPressure.code.coding:snomed.code",
"path": "Observation.component.code.coding.code",
"min": 1
},
{
"id": "Observation.component:systolicBloodPressure.value[x]",
"path": "Observation.component.value[x]",
"slicing": {
"discriminator": [
{
"type": "type",
"path": "$this"
}
],
"rules": "open"
},
"type": [
{
"code": "Quantity"
}
],
"mustSupport": true
},
{
"id": "Observation.component:systolicBloodPressure.valueQuantity",
"path": "Observation.component.valueQuantity",
"short": "Systolic blood pressure value",
"min": 0,
"max": "1",
"mustSupport": true
},
{
"id": "Observation.component:systolicBloodPressure.valueQuantity.value",
"path": "Observation.component.valueQuantity.value",
"min": 1
},
{
"id": "Observation.component:systolicBloodPressure.valueQuantity.unit",
"path": "Observation.component.valueQuantity.unit",
"min": 1
},
{
"id": "Observation.component:systolicBloodPressure.valueQuantity.system",
"path": "Observation.component.valueQuantity.system",
"min": 1,
"patternUri": "http://unitsofmeasure.org"
},
{
"id": "Observation.component:systolicBloodPressure.valueQuantity.code",
"path": "Observation.component.valueQuantity.code",
"min": 1,
"patternCode": "mm[Hg]"
},
{
"id": "Observation.component:diastolicBloodPressure",
"path": "Observation.component",
"sliceName": "diastolicBloodPressure",
"short": "Diastolic blood pressure",
"min": 1,
"max": "1",
"mustSupport": true
},
{
"id": "Observation.component:diastolicBloodPressure.code",
"path": "Observation.component.code",
"patternCodeableConcept": {
"coding": [
{
"system": "http://loinc.org",
"code": "8462-4"
}
]
},
"mustSupport": true
},
{
"id": "Observation.component:diastolicBloodPressure.code.coding",
"path": "Observation.component.code.coding",
"slicing": {
"discriminator": [
{
"type": "pattern",
"path": "$this"
}
],
"rules": "open"
},
"min": 1
},
{
"id": "Observation.component:diastolicBloodPressure.code.coding:loinc",
"path": "Observation.component.code.coding",
"sliceName": "loinc",
"min": 1,
"max": "*",
"patternCoding": {
"system": "http://loinc.org",
"code": "8462-4"
}
},
{
"id": "Observation.component:diastolicBloodPressure.code.coding:loinc.system",
"path": "Observation.component.code.coding.system",
"min": 1
},
{
"id": "Observation.component:diastolicBloodPressure.code.coding:loinc.code",
"path": "Observation.component.code.coding.code",
"min": 1
},
{
"id": "Observation.component:diastolicBloodPressure.code.coding:snomed",
"path": "Observation.component.code.coding",
"sliceName": "snomed",
"min": 0,
"max": "*",
"patternCoding": {
"system": "http://snomed.info/sct",
"code": "271650006"
}
},
{
"id": "Observation.component:diastolicBloodPressure.code.coding:snomed.system",
"path": "Observation.component.code.coding.system",
"min": 1
},
{
"id": "Observation.component:diastolicBloodPressure.code.coding:snomed.code",
"path": "Observation.component.code.coding.code",
"min": 1
},
{
"id": "Observation.component:diastolicBloodPressure.value[x]",
"path": "Observation.component.value[x]",
"slicing": {
"discriminator": [
{
"type": "type",
"path": "$this"
}
],
"rules": "open"
},
"type": [
{
"code": "Quantity"
}
],
"mustSupport": true
},
{
"id": "Observation.component:diastolicBloodPressure.valueQuantity",
"path": "Observation.component.valueQuantity",
"short": "Diastolic blood pressure value",
"min": 0,
"max": "1",
"mustSupport": true
},
{
"id": "Observation.component:diastolicBloodPressure.valueQuantity.value",
"path": "Observation.component.valueQuantity.value",
"min": 1
},
{
"id": "Observation.component:diastolicBloodPressure.valueQuantity.unit",
"path": "Observation.component.valueQuantity.unit",
"min": 1
},
{
"id": "Observation.component:diastolicBloodPressure.valueQuantity.system",
"path": "Observation.component.valueQuantity.system",
"min": 1,
"patternUri": "http://unitsofmeasure.org"
},
{
"id": "Observation.component:diastolicBloodPressure.valueQuantity.code",
"path": "Observation.component.valueQuantity.code",
"min": 1,
"patternCode": "mm[Hg]"
}
]
}
}