| Package | ch.fhir.ig.ch-ems |
| Resource Type | ConceptMap |
| Id | EmsHandover2Fhir |
| FHIR Version | R4 |
| Source | http://fhir.ch/ig/ch-ems/https://build.fhir.org/ig/hl7ch/ch-ems/ConceptMap-EmsHandover2Fhir.html |
| URL | http://fhir.ch/ig/ch-ems/ConceptMap/EmsHandover2Fhir |
| Version | 2.1.0-ci-build |
| Status | active |
| Date | 2025-08-06T11:55:40+00:00 |
| Name | EmsHandover2Fhir |
| Title | EMS Handover to FHIR Mapping |
| Realm | ch |
| Authority | hl7 |
| Description | This map shows how the handover section from the EMS Protocol is represented using FHIR. |
| Copyright | CC0-1.0 |
No resources found
| StructureDefinition | |
| ch-ems-composition | CH EMS Composition |
| ch-ems-document | CH EMS Document |
| ch-ems-observation-conditionchange | CH EMS Observation: Condition Change |
| ch-ems-observation-gcs | CH EMS Observation: GCS |
| ch-ems-observation-naca | CH EMS Observation: NACA |
| ch-ems-observation-statuspriority | CH EMS Observation: Status Priority |
| ch-ems-organization | CH EMS Organization |
| ch-ems-practitioner | CH EMS Practitioner |
| logicalmodel-ems-protocol | EMS Protocol |
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap EmsHandover2Fhir
Mapping from EMS Protocol to CH EMS Document
Group 1 Mapping from EMS Protocol to CH EMS Composition
| Source Code | Relationship | Target Code |
| EMSProtocol.handover | is equivalent to | Composition.section:handover |
Group 2 Mapping from EMS Protocol to CH EMS Observation: Status Priority
| Source Code | Relationship | Target Code |
| EMSProtocol.handover.priority | is equivalent to | Observation.valueCodeableConcept |
Group 3 Mapping from EMS Protocol to CH EMS Observation: Condition Change
| Source Code | Relationship | Target Code |
| EMSProtocol.handover.conditionChange | is equivalent to | Observation.valueCodeableConcept |
Group 4 Mapping from EMS Protocol to CH EMS Observation: NACA
| Source Code | Relationship | Target Code |
| EMSProtocol.handover.injurySeverity | is equivalent to | Observation.valueCodeableConcept |
Group 5 Mapping from EMS Protocol to CH EMS Observation: GCS
| Source Code | Relationship | Target Code |
| EMSProtocol.handover.gcs.total | is equivalent to | Observation.valueQuantity |
| EMSProtocol.handover.gcs.eyeOpening.score | is equivalent to | Observation.component:eyeOpening.valueCodeableConcept.coding.extension:itemWeight |
| EMSProtocol.handover.gcs.eyeOpening.description | is equivalent to | Observation.component:eyeOpening.valueCodeableConcept |
| EMSProtocol.handover.gcs.verbalResponse.score | is equivalent to | Observation.component:verbal.valueCodeableConcept.coding.extension:itemWeight |
| EMSProtocol.handover.gcs.verbalResponse.description | is equivalent to | Observation.component:verbal.valueCodeableConcept |
| EMSProtocol.handover.gcs.motorResponse.score | is equivalent to | Observation.component:motor.valueCodeableConcept.coding.extension:itemWeight |
| EMSProtocol.handover.gcs.motorResponse.description | is equivalent to | Observation.component:motor.valueCodeableConcept |
Group 6 Mapping from EMS Protocol to CH EMS Organization
| Source Code | Relationship | Target Code |
| EMSProtocol.handover.recipient.organisation | is equivalent to | Organization |
Group 7 Mapping from EMS Protocol to CH EMS Practitioner
| Source Code | Relationship | Target Code |
| EMSProtocol.handover.recipient.practitioner | is equivalent to | Practitioner |
{
"resourceType": "ConceptMap",
"id": "EmsHandover2Fhir",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"url": "http://fhir.ch/ig/ch-ems/ConceptMap/EmsHandover2Fhir",
"version": "2.1.0-ci-build",
"name": "EmsHandover2Fhir",
"title": "EMS Handover to FHIR Mapping",
"status": "active",
"experimental": false,
"date": "2025-08-06T11:55:40+00:00",
"publisher": "IVR Interverband für Rettungswesen",
"contact": [
{
"name": "IVR Interverband für Rettungswesen",
"telecom": [
{
"system": "url",
"value": "https://www.ivr-ias.ch/"
}
]
}
],
"description": "This map shows how the handover section from the EMS Protocol is represented using FHIR.",
"jurisdiction": [
{
"coding": [
{
"system": "urn:iso:std:iso:3166",
"code": "CH"
}
]
}
],
"copyright": "CC0-1.0",
"sourceUri": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"targetUri": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-document",
"group": [
{
"source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-composition",
"element": [
{
"code": "EMSProtocol.handover",
"target": [
{
"code": "Composition.section:handover",
"equivalence": "equivalent"
}
]
}
]
},
{
"source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-statuspriority",
"element": [
{
"code": "EMSProtocol.handover.priority",
"target": [
{
"code": "Observation.valueCodeableConcept",
"equivalence": "equivalent"
}
]
}
]
},
{
"source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-conditionchange",
"element": [
{
"code": "EMSProtocol.handover.conditionChange",
"target": [
{
"code": "Observation.valueCodeableConcept",
"equivalence": "equivalent"
}
]
}
]
},
{
"source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-naca",
"element": [
{
"code": "EMSProtocol.handover.injurySeverity",
"target": [
{
"code": "Observation.valueCodeableConcept",
"equivalence": "equivalent"
}
]
}
]
},
{
"source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-gcs",
"element": [
{
"code": "EMSProtocol.handover.gcs.total",
"target": [
{
"code": "Observation.valueQuantity",
"equivalence": "equivalent"
}
]
},
{
"code": "EMSProtocol.handover.gcs.eyeOpening.score",
"target": [
{
"code": "Observation.component:eyeOpening.valueCodeableConcept.coding.extension:itemWeight",
"equivalence": "equivalent"
}
]
},
{
"code": "EMSProtocol.handover.gcs.eyeOpening.description",
"target": [
{
"code": "Observation.component:eyeOpening.valueCodeableConcept",
"equivalence": "equivalent"
}
]
},
{
"code": "EMSProtocol.handover.gcs.verbalResponse.score",
"target": [
{
"code": "Observation.component:verbal.valueCodeableConcept.coding.extension:itemWeight",
"equivalence": "equivalent"
}
]
},
{
"code": "EMSProtocol.handover.gcs.verbalResponse.description",
"target": [
{
"code": "Observation.component:verbal.valueCodeableConcept",
"equivalence": "equivalent"
}
]
},
{
"code": "EMSProtocol.handover.gcs.motorResponse.score",
"target": [
{
"code": "Observation.component:motor.valueCodeableConcept.coding.extension:itemWeight",
"equivalence": "equivalent"
}
]
},
{
"code": "EMSProtocol.handover.gcs.motorResponse.description",
"target": [
{
"code": "Observation.component:motor.valueCodeableConcept",
"equivalence": "equivalent"
}
]
}
]
},
{
"source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-organization",
"element": [
{
"code": "EMSProtocol.handover.recipient.organisation",
"target": [
{
"code": "Organization",
"equivalence": "equivalent"
}
]
}
]
},
{
"source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
"target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-practitioner",
"element": [
{
"code": "EMSProtocol.handover.recipient.practitioner",
"target": [
{
"code": "Practitioner",
"equivalence": "equivalent"
}
]
}
]
}
]
}