Package | ch.fhir.ig.ch-ems |
Resource Type | ConceptMap |
Id | EmsHandover2Fhir |
FHIR Version | R4 |
Source | http://fhir.ch/ig/ch-ems/https://build.fhir.org/ig/hl7ch/ch-ems/ConceptMap-EmsHandover2Fhir.html |
URL | http://fhir.ch/ig/ch-ems/ConceptMap/EmsHandover2Fhir |
Version | 2.1.0-ci-build |
Status | active |
Date | 2025-08-06T11:55:40+00:00 |
Name | EmsHandover2Fhir |
Title | EMS Handover to FHIR Mapping |
Realm | ch |
Authority | hl7 |
Description | This map shows how the handover section from the EMS Protocol is represented using FHIR. |
Copyright | CC0-1.0 |
No resources found
StructureDefinition | |
ch-ems-composition | CH EMS Composition |
ch-ems-document | CH EMS Document |
ch-ems-observation-conditionchange | CH EMS Observation: Condition Change |
ch-ems-observation-gcs | CH EMS Observation: GCS |
ch-ems-observation-naca | CH EMS Observation: NACA |
ch-ems-observation-statuspriority | CH EMS Observation: Status Priority |
ch-ems-organization | CH EMS Organization |
ch-ems-practitioner | CH EMS Practitioner |
logicalmodel-ems-protocol | EMS Protocol |
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap EmsHandover2Fhir
Mapping from EMS Protocol to CH EMS Document
Group 1 Mapping from EMS Protocol to CH EMS Composition
Source Code | Relationship | Target Code |
EMSProtocol.handover | is equivalent to | Composition.section:handover |
Group 2 Mapping from EMS Protocol to CH EMS Observation: Status Priority
Source Code | Relationship | Target Code |
EMSProtocol.handover.priority | is equivalent to | Observation.valueCodeableConcept |
Group 3 Mapping from EMS Protocol to CH EMS Observation: Condition Change
Source Code | Relationship | Target Code |
EMSProtocol.handover.conditionChange | is equivalent to | Observation.valueCodeableConcept |
Group 4 Mapping from EMS Protocol to CH EMS Observation: NACA
Source Code | Relationship | Target Code |
EMSProtocol.handover.injurySeverity | is equivalent to | Observation.valueCodeableConcept |
Group 5 Mapping from EMS Protocol to CH EMS Observation: GCS
Source Code | Relationship | Target Code |
EMSProtocol.handover.gcs.total | is equivalent to | Observation.valueQuantity |
EMSProtocol.handover.gcs.eyeOpening.score | is equivalent to | Observation.component:eyeOpening.valueCodeableConcept.coding.extension:itemWeight |
EMSProtocol.handover.gcs.eyeOpening.description | is equivalent to | Observation.component:eyeOpening.valueCodeableConcept |
EMSProtocol.handover.gcs.verbalResponse.score | is equivalent to | Observation.component:verbal.valueCodeableConcept.coding.extension:itemWeight |
EMSProtocol.handover.gcs.verbalResponse.description | is equivalent to | Observation.component:verbal.valueCodeableConcept |
EMSProtocol.handover.gcs.motorResponse.score | is equivalent to | Observation.component:motor.valueCodeableConcept.coding.extension:itemWeight |
EMSProtocol.handover.gcs.motorResponse.description | is equivalent to | Observation.component:motor.valueCodeableConcept |
Group 6 Mapping from EMS Protocol to CH EMS Organization
Source Code | Relationship | Target Code |
EMSProtocol.handover.recipient.organisation | is equivalent to | Organization |
Group 7 Mapping from EMS Protocol to CH EMS Practitioner
Source Code | Relationship | Target Code |
EMSProtocol.handover.recipient.practitioner | is equivalent to | Practitioner |
{ "resourceType": "ConceptMap", "id": "EmsHandover2Fhir", "text": { "status": "generated", "div": "<!-- snip (see above) -->" }, "url": "http://fhir.ch/ig/ch-ems/ConceptMap/EmsHandover2Fhir", "version": "2.1.0-ci-build", "name": "EmsHandover2Fhir", "title": "EMS Handover to FHIR Mapping", "status": "active", "experimental": false, "date": "2025-08-06T11:55:40+00:00", "publisher": "IVR Interverband für Rettungswesen", "contact": [ { "name": "IVR Interverband für Rettungswesen", "telecom": [ { "system": "url", "value": "https://www.ivr-ias.ch/" } ] } ], "description": "This map shows how the handover section from the EMS Protocol is represented using FHIR.", "jurisdiction": [ { "coding": [ { "system": "urn:iso:std:iso:3166", "code": "CH" } ] } ], "copyright": "CC0-1.0", "sourceUri": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "targetUri": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-document", "group": [ { "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-composition", "element": [ { "code": "EMSProtocol.handover", "target": [ { "code": "Composition.section:handover", "equivalence": "equivalent" } ] } ] }, { "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-statuspriority", "element": [ { "code": "EMSProtocol.handover.priority", "target": [ { "code": "Observation.valueCodeableConcept", "equivalence": "equivalent" } ] } ] }, { "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-conditionchange", "element": [ { "code": "EMSProtocol.handover.conditionChange", "target": [ { "code": "Observation.valueCodeableConcept", "equivalence": "equivalent" } ] } ] }, { "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-naca", "element": [ { "code": "EMSProtocol.handover.injurySeverity", "target": [ { "code": "Observation.valueCodeableConcept", "equivalence": "equivalent" } ] } ] }, { "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-gcs", "element": [ { "code": "EMSProtocol.handover.gcs.total", "target": [ { "code": "Observation.valueQuantity", "equivalence": "equivalent" } ] }, { "code": "EMSProtocol.handover.gcs.eyeOpening.score", "target": [ { "code": "Observation.component:eyeOpening.valueCodeableConcept.coding.extension:itemWeight", "equivalence": "equivalent" } ] }, { "code": "EMSProtocol.handover.gcs.eyeOpening.description", "target": [ { "code": "Observation.component:eyeOpening.valueCodeableConcept", "equivalence": "equivalent" } ] }, { "code": "EMSProtocol.handover.gcs.verbalResponse.score", "target": [ { "code": "Observation.component:verbal.valueCodeableConcept.coding.extension:itemWeight", "equivalence": "equivalent" } ] }, { "code": "EMSProtocol.handover.gcs.verbalResponse.description", "target": [ { "code": "Observation.component:verbal.valueCodeableConcept", "equivalence": "equivalent" } ] }, { "code": "EMSProtocol.handover.gcs.motorResponse.score", "target": [ { "code": "Observation.component:motor.valueCodeableConcept.coding.extension:itemWeight", "equivalence": "equivalent" } ] }, { "code": "EMSProtocol.handover.gcs.motorResponse.description", "target": [ { "code": "Observation.component:motor.valueCodeableConcept", "equivalence": "equivalent" } ] } ] }, { "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-organization", "element": [ { "code": "EMSProtocol.handover.recipient.organisation", "target": [ { "code": "Organization", "equivalence": "equivalent" } ] } ] }, { "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol", "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-practitioner", "element": [ { "code": "EMSProtocol.handover.recipient.practitioner", "target": [ { "code": "Practitioner", "equivalence": "equivalent" } ] } ] } ] }