FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagech.fhir.ig.ch-ems
Resource TypeConceptMap
IdConceptMap-EmsHandover2Fhir.json
FHIR VersionR4
Sourcehttp://fhir.ch/ig/ch-ems/2.0.0-ballot/ConceptMap-EmsHandover2Fhir.html
URLhttp://fhir.ch/ig/ch-ems/ConceptMap/EmsHandover2Fhir
Version2.0.0-ballot
Statusactive
Date2026-06-15T08:00:21+00:00
NameEmsHandover2Fhir
TitleEMS Handover to FHIR Mapping
Realmch
Authorityhl7
DescriptionThis map shows how the handover section from the EMS Protocol is represented using FHIR.
CopyrightCC0-1.0

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
ch.fhir.ig.ch-ems#2.0.0-ballotch-ems-compositionCH EMS Composition
ch.fhir.ig.ch-ems#2.0.0-ballotch-ems-observation-conditionchangeCH EMS Observation: Condition Change
ch.fhir.ig.ch-ems#2.0.0-ballotch-ems-observation-gcsCH EMS Observation: GCS
ch.fhir.ig.ch-ems#2.0.0-ballotch-ems-observation-nacaCH EMS Observation: NACA
ch.fhir.ig.ch-ems#2.0.0-ballotch-ems-observation-statuspriorityCH EMS Observation: Status Priority
ch.fhir.ig.ch-ems#2.0.0-ballotch-ems-organizationCH EMS Organization
ch.fhir.ig.ch-ems#2.0.0-ballotch-ems-practitionerCH EMS Practitioner
ch.fhir.ig.ch-ems#2.0.0-ballotlogicalmodel-ems-protocolEMS Protocol

Narrative

Note: links and images are rebased to the (stated) source

Mapping from (not specified) to (not specified)


Group 1 Mapping from EMS Protocol to CH EMS Composition

Source CodeCard.TypeRelationshipTarget CodeCard.Type
EMSProtocol.handover0..1todois equivalent toComposition.section:handover0..1todo

Group 2 Mapping from EMS Protocol to CH EMS Observation: Status Priority

Source CodeCard.TypeRelationshipTarget CodeCard.Type
EMSProtocol.handover.priority0..1todois equivalent toObservation.value[x]0..1todo

Group 3 Mapping from EMS Protocol to CH EMS Observation: Condition Change

Source CodeCard.TypeRelationshipTarget CodeCard.Type
EMSProtocol.handover.conditionChange0..1todois equivalent toObservation.value[x]0..1todo

Group 4 Mapping from EMS Protocol to CH EMS Observation: NACA

Source CodeCard.TypeRelationshipTarget CodeCard.Type
EMSProtocol.handover.injurySeverity0..1todois equivalent toObservation.value[x]0..1todo

Group 5 Mapping from EMS Protocol to CH EMS Observation: GCS

Source CodeCard.TypeRelationshipTarget CodeCard.Type
EMSProtocol.handover.gcs.total0..1todois equivalent toObservation.value[x]0..1todo
EMSProtocol.handover.gcs.eyeOpening.score0..1todois equivalent toObservation.component:eyeOpening.value[x].coding.extension:itemWeight0..1todo
EMSProtocol.handover.gcs.eyeOpening.description0..1todois equivalent toObservation.component:eyeOpening.value[x]0..1todo
EMSProtocol.handover.gcs.verbalResponse.score0..1todois equivalent toObservation.component:verbal.value[x].coding.extension:itemWeight0..1todo
EMSProtocol.handover.gcs.verbalResponse.description0..1todois equivalent toObservation.component:verbal.value[x]0..1todo
EMSProtocol.handover.gcs.motorResponse.score0..1todois equivalent toObservation.component:motor.value[x].coding.extension:itemWeight0..1todo
EMSProtocol.handover.gcs.motorResponse.description0..1todois equivalent toObservation.component:motor.value[x]0..1todo

Group 6 Mapping from EMS Protocol to CH EMS Organization

Source CodeCard.TypeRelationshipTarget CodeCard.Type
EMSProtocol.handover.recipient.organisation1..1todois equivalent toOrganization0..*todo

Group 7 Mapping from EMS Protocol to CH EMS Practitioner

Source CodeCard.TypeRelationshipTarget CodeCard.Type
EMSProtocol.handover.recipient.practitioner0..*todois equivalent toPractitioner0..*todo

Source1

{
  "resourceType": "ConceptMap",
  "id": "EmsHandover2Fhir",
  "text": {
    "status": "additional",
    "div": "<!-- snip (see above) -->"
  },
  "url": "http://fhir.ch/ig/ch-ems/ConceptMap/EmsHandover2Fhir",
  "version": "2.0.0-ballot",
  "name": "EmsHandover2Fhir",
  "title": "EMS Handover to FHIR Mapping",
  "status": "active",
  "experimental": false,
  "date": "2026-06-15T08:00:21+00:00",
  "publisher": "HL7 Switzerland",
  "contact": [
    {
      "name": "HL7 Switzerland",
      "telecom": [
        {
          "system": "url",
          "value": "https://www.hl7.ch/"
        }
      ]
    },
    {
      "name": "HL7 Switzerland",
      "telecom": [
        {
          "system": "url",
          "value": "https://www.hl7.ch/",
          "use": "work"
        }
      ]
    }
  ],
  "description": "This map shows how the handover section from the EMS Protocol is represented using FHIR.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "urn:iso:std:iso:3166",
          "code": "CH"
        }
      ]
    }
  ],
  "copyright": "CC0-1.0",
  "group": [
    {
      "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
      "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-composition",
      "element": [
        {
          "code": "EMSProtocol.handover",
          "target": [
            {
              "code": "Composition.section:handover",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    },
    {
      "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
      "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-statuspriority",
      "element": [
        {
          "code": "EMSProtocol.handover.priority",
          "target": [
            {
              "code": "Observation.value[x]",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    },
    {
      "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
      "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-conditionchange",
      "element": [
        {
          "code": "EMSProtocol.handover.conditionChange",
          "target": [
            {
              "code": "Observation.value[x]",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    },
    {
      "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
      "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-naca",
      "element": [
        {
          "code": "EMSProtocol.handover.injurySeverity",
          "target": [
            {
              "code": "Observation.value[x]",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    },
    {
      "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
      "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-observation-gcs",
      "element": [
        {
          "code": "EMSProtocol.handover.gcs.total",
          "target": [
            {
              "code": "Observation.value[x]",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "EMSProtocol.handover.gcs.eyeOpening.score",
          "target": [
            {
              "code": "Observation.component:eyeOpening.value[x].coding.extension:itemWeight",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "EMSProtocol.handover.gcs.eyeOpening.description",
          "target": [
            {
              "code": "Observation.component:eyeOpening.value[x]",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "EMSProtocol.handover.gcs.verbalResponse.score",
          "target": [
            {
              "code": "Observation.component:verbal.value[x].coding.extension:itemWeight",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "EMSProtocol.handover.gcs.verbalResponse.description",
          "target": [
            {
              "code": "Observation.component:verbal.value[x]",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "EMSProtocol.handover.gcs.motorResponse.score",
          "target": [
            {
              "code": "Observation.component:motor.value[x].coding.extension:itemWeight",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "EMSProtocol.handover.gcs.motorResponse.description",
          "target": [
            {
              "code": "Observation.component:motor.value[x]",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    },
    {
      "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
      "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-organization",
      "element": [
        {
          "code": "EMSProtocol.handover.recipient.organisation",
          "target": [
            {
              "code": "Organization",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    },
    {
      "source": "http://fhir.ch/ig/ch-ems/StructureDefinition/logicalmodel-ems-protocol",
      "target": "http://fhir.ch/ig/ch-ems/StructureDefinition/ch-ems-practitioner",
      "element": [
        {
          "code": "EMSProtocol.handover.recipient.practitioner",
          "target": [
            {
              "code": "Practitioner",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    }
  ]
}