FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packageans.fr.document-core
Resource TypeStructureDefinition
IdStructureDefinition-fr-lm-technique-imagerie.json
FHIR VersionR4
Sourcehttps://build.fhir.org/ig/ansforge/interop-IG-metier-document-core/StructureDefinition-fr-lm-technique-imagerie.html
URLhttps://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-technique-imagerie
Version0.1.0
Statusdraft
Date2026-07-16T16:44:47+00:00
NameFRLMTechniqueImagerie
TitleLogical model- FR LM Technique imagerie
Realmfr
DescriptionEntrée Technique imagerie
Typehttps://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-technique-imagerie
Kindlogical

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
ans.fr.document-core#currentfr-lm-entryLogical model - FR LM Entry

Narrative

Note: links and images are rebased to the (stated) source


French


Narratif généré : DéfinitionStructure fr-lm-technique-imagerie

NomDrapeauxCard.TypeDescription et contraintesdoco
.. fr-lm-technique-imagerie 0..*FRLMEntry(0.1.0)Logical model- FR LM Technique imagerie

Éléments définis dans les ancêtres :header
Les instances de ce modèle logique peuvent être la cible d'une référence
... codeActe 1..1CodeableConceptCode de l'acte d'imagerie
Description du binding: : jdv-code-document-imagerie-cisis (1.2.250.1.213.1.1.5.687)
... description 0..1NarrativePartie narrative de l'observation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... modaliteAcquisition 1..*CodeableConceptModalité d’acquisition
Description du binding: : jdv-modalite-acquisition-cisis (1.2.250.1.213.1.1.5.618)
... lateralite 0..1CodeableConceptLatéralité et topographie
Description du binding: : SNOMED CT (2.16.840.1.113883.6.96)
.... precisionTopographique 0..1CodeableConceptPrécision topographique
..... nom 1..1CodeableConceptname
..... valeur 1..1CodeableConceptValeur de la topographie
Description du binding: : jdv-modificateur-topographique-cisis (1.2.250.1.213.1.1.5.688)

doco Documentation pour ce format

English


Generated Narrative: StructureDefinition fr-lm-technique-imagerie

NameFlagsCard.TypeDescription & Constraintsdoco
.. fr-lm-technique-imagerie 0..*FRLMEntry(0.1.0)Logical model- FR LM Technique imagerie

Elements defined in Ancestors:header
Instances of this type can be the target of a Reference
... codeActe 1..1CodeableConceptCode de l'acte d'imagerie
Binding Description: : jdv-code-document-imagerie-cisis (1.2.250.1.213.1.1.5.687)
... description 0..1NarrativePartie narrative de l'observation
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... modaliteAcquisition 1..*CodeableConceptModalité d’acquisition
Binding Description: : jdv-modalite-acquisition-cisis (1.2.250.1.213.1.1.5.618)
... lateralite 0..1CodeableConceptLatéralité et topographie
Binding Description: : SNOMED CT (2.16.840.1.113883.6.96)
.... precisionTopographique 0..1CodeableConceptPrécision topographique
..... nom 1..1CodeableConceptname
..... valeur 1..1CodeableConceptValeur de la topographie
Binding Description: : jdv-modificateur-topographique-cisis (1.2.250.1.213.1.1.5.688)

doco Documentation for this format

Source1

{
  "resourceType": "StructureDefinition",
  "id": "fr-lm-technique-imagerie",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-type-characteristics",
      "valueCode": "can-be-target"
    }
  ],
  "url": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-technique-imagerie",
  "version": "0.1.0",
  "name": "FRLMTechniqueImagerie",
  "title": "Logical model- FR LM Technique imagerie",
  "status": "draft",
  "date": "2026-07-16T16:44:47+00:00",
  "publisher": "Agence du Numérique en Santé (ANS) - 2-10 Rue d'Oradour-sur-Glane, 75015 Paris",
  "contact": [
    {
      "name": "Agence du Numérique en Santé (ANS) - 2-10 Rue d'Oradour-sur-Glane, 75015 Paris",
      "telecom": [
        {
          "system": "url",
          "value": "https://esante.gouv.fr"
        }
      ]
    }
  ],
  "description": "Entrée Technique imagerie",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "urn:iso:std:iso:3166",
          "code": "FR",
          "display": "France (la)"
        }
      ]
    }
  ],
  "fhirVersion": "4.0.1",
  "kind": "logical",
  "abstract": false,
  "type": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-technique-imagerie",
  "baseDefinition": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-entry|0.1.0",
  "derivation": "specialization",
  "snapshot": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
        "valueString": "0.1.0"
      }
    ],
    "element": [
      {
        "id": "fr-lm-technique-imagerie",
        "path": "fr-lm-technique-imagerie",
        "short": "Logical model- FR LM Technique imagerie",
        "definition": "Entrée Technique imagerie",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Base",
          "min": 0,
          "max": "*"
        },
        "isModifier": false
      },
      {
        "id": "fr-lm-technique-imagerie.header",
        "path": "fr-lm-technique-imagerie.header",
        "short": "Métadonnées de base",
        "definition": "Métadonnées de base",
        "min": 1,
        "max": "1",
        "base": {
          "path": "fr-lm-entry.header",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.subject",
        "path": "fr-lm-technique-imagerie.header.subject",
        "short": "Patient / Usager",
        "definition": "Patient / Usager",
        "min": 1,
        "max": "1",
        "base": {
          "path": "fr-lm-entry.header.subject",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-patient"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.identifier",
        "path": "fr-lm-technique-imagerie.header.identifier",
        "short": "Identifiant de l’entrée",
        "definition": "Identifiant de l’entrée",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.identifier",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Identifier"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.author[x]",
        "path": "fr-lm-technique-imagerie.header.author[x]",
        "short": "author[x] peut correspondre soit à un professionnel, soit à une organisation, soit à un système.",
        "definition": "author[x] peut correspondre soit à un professionnel, soit à une organisation, soit à un système.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.author[x]",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.author[x].authorProfessional",
        "path": "fr-lm-technique-imagerie.header.author[x].authorProfessional",
        "short": "L'auteur est un professionnel de santé",
        "definition": "L'auteur est un professionnel de santé",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.author[x].authorProfessional",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-health-professional"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.author[x].authorOrganisation",
        "path": "fr-lm-technique-imagerie.header.author[x].authorOrganisation",
        "short": "L'auteur est une organisation",
        "definition": "L'auteur est une organisation",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.author[x].authorOrganisation",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-organisation"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.author[x].authorDevice",
        "path": "fr-lm-technique-imagerie.header.author[x].authorDevice",
        "short": "L'auteur est un système",
        "definition": "L'auteur est un système",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.author[x].authorDevice",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-device"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.performer[x]",
        "path": "fr-lm-technique-imagerie.header.performer[x]",
        "short": "Exécutant (performer)",
        "definition": "Exécutant (performer)",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.performer[x]",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-health-professional"
          },
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-organisation"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.participant[x]",
        "path": "fr-lm-technique-imagerie.header.participant[x]",
        "short": "Participant",
        "definition": "Participant",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.participant[x]",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.participant[x].participantProfessional",
        "path": "fr-lm-technique-imagerie.header.participant[x].participantProfessional",
        "short": "Le participant est un professionnel de santé",
        "definition": "Le participant est un professionnel de santé",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.participant[x].participantProfessional",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-health-professional"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.participant[x].participantOrganisation",
        "path": "fr-lm-technique-imagerie.header.participant[x].participantOrganisation",
        "short": "Le participant est une organisation",
        "definition": "Le participant est une organisation",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.participant[x].participantOrganisation",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-organisation"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.participant[x].participantDevice",
        "path": "fr-lm-technique-imagerie.header.participant[x].participantDevice",
        "short": "Le participant est un système",
        "definition": "Le participant est un système",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.participant[x].participantDevice",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-device"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.informant",
        "path": "fr-lm-technique-imagerie.header.informant",
        "short": "Informateur",
        "definition": "Informateur",
        "min": 0,
        "max": "*",
        "base": {
          "path": "fr-lm-entry.header.informant",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://interop.esante.gouv.fr/ig/document-core/StructureDefinition/fr-lm-informant"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.date",
        "path": "fr-lm-technique-imagerie.header.date",
        "short": "Date/Heure de création par l'auteur",
        "definition": "Date/Heure de création par l'auteur",
        "min": 0,
        "max": "1",
        "base": {
          "path": "fr-lm-entry.header.date",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.status",
        "path": "fr-lm-technique-imagerie.header.status",
        "short": "Statut",
        "definition": "Statut",
        "min": 0,
        "max": "1",
        "base": {
          "path": "fr-lm-entry.header.status",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.source",
        "path": "fr-lm-technique-imagerie.header.source",
        "short": "Source",
        "definition": "Source",
        "min": 0,
        "max": "1",
        "base": {
          "path": "fr-lm-entry.header.source",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.header.language",
        "path": "fr-lm-technique-imagerie.header.language",
        "short": "'fr-FR' pour français métropolitain (la casse des caractères doit être respectée)\nLa partie en minuscules indique le code de la langue utilisée (ISO-639-1)\nLa partie en majuscules indique le code pays (ISO-3166)",
        "definition": "'fr-FR' pour français métropolitain (la casse des caractères doit être respectée)\nLa partie en minuscules indique le code de la langue utilisée (ISO-639-1)\nLa partie en majuscules indique le code pays (ISO-3166)",
        "min": 0,
        "max": "1",
        "base": {
          "path": "fr-lm-entry.header.language",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.codeActe",
        "path": "fr-lm-technique-imagerie.codeActe",
        "short": "Code de l'acte d'imagerie",
        "definition": "Code de l'acte d'imagerie",
        "min": 1,
        "max": "1",
        "base": {
          "path": "fr-lm-technique-imagerie.codeActe",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "description": "jdv-code-document-imagerie-cisis (1.2.250.1.213.1.1.5.687)"
        }
      },
      {
        "id": "fr-lm-technique-imagerie.description",
        "path": "fr-lm-technique-imagerie.description",
        "short": "Partie narrative de l'observation",
        "definition": "Partie narrative de l'observation",
        "min": 0,
        "max": "1",
        "base": {
          "path": "fr-lm-technique-imagerie.description",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Narrative"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.modaliteAcquisition",
        "path": "fr-lm-technique-imagerie.modaliteAcquisition",
        "short": "Modalité d’acquisition",
        "definition": "Modalité d’acquisition",
        "min": 1,
        "max": "*",
        "base": {
          "path": "fr-lm-technique-imagerie.modaliteAcquisition",
          "min": 1,
          "max": "*"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "description": "jdv-modalite-acquisition-cisis (1.2.250.1.213.1.1.5.618)"
        }
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite",
        "path": "fr-lm-technique-imagerie.lateralite",
        "short": "Latéralité et topographie",
        "definition": "Latéralité et topographie",
        "min": 0,
        "max": "1",
        "base": {
          "path": "fr-lm-technique-imagerie.lateralite",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          }
        ],
        "binding": {
          "description": "SNOMED CT (2.16.840.1.113883.6.96)"
        }
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.id",
        "path": "fr-lm-technique-imagerie.lateralite.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "Unique id for inter-element referencing",
        "definition": "Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fhir-type",
                "valueUrl": "string"
              }
            ],
            "code": "http://hl7.org/fhirpath/System.String"
          }
        ],
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.extension",
        "path": "fr-lm-technique-imagerie.lateralite.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), \"value\")])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension|4.0.1"
          }
        ],
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.coding",
        "path": "fr-lm-technique-imagerie.lateralite.coding",
        "short": "Code defined by a terminology system",
        "definition": "A reference to a code defined by a terminology system.",
        "comment": "Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information.  Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.",
        "requirements": "Allows for alternative encodings within a code system, and translations to other code systems.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "CodeableConcept.coding",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Coding"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          }
        ],
        "isModifier": false,
        "isSummary": true,
        "mapping": [
          {
            "identity": "v2",
            "map": "C*E.1-8, C*E.10-22"
          },
          {
            "identity": "rim",
            "map": "union(., ./translation)"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept.coding rdfs:subPropertyOf dt:CD.coding"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.text",
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-translatable",
            "valueBoolean": true
          }
        ],
        "path": "fr-lm-technique-imagerie.lateralite.text",
        "short": "Plain text representation of the concept",
        "definition": "A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user.",
        "comment": "Very often the text is the same as a displayName of one of the codings.",
        "requirements": "The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "CodeableConcept.text",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          }
        ],
        "isModifier": false,
        "isSummary": true,
        "mapping": [
          {
            "identity": "v2",
            "map": "C*E.9. But note many systems use C*E.2 for this"
          },
          {
            "identity": "rim",
            "map": "./originalText[mediaType/code=\"text/plain\"]/data"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept.text rdfs:subPropertyOf dt:CD.originalText"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique",
        "short": "Précision topographique",
        "definition": "Précision topographique",
        "min": 0,
        "max": "1",
        "base": {
          "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.id",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "Unique id for inter-element referencing",
        "definition": "Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fhir-type",
                "valueUrl": "string"
              }
            ],
            "code": "http://hl7.org/fhirpath/System.String"
          }
        ],
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.extension",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Additional content defined by implementations",
        "definition": "May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance  applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.",
        "comment": "There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions.  The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.",
        "alias": [
          "extensions",
          "user content"
        ],
        "min": 0,
        "max": "*",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), \"value\")])",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension|4.0.1"
          }
        ],
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.coding",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.coding",
        "short": "Code defined by a terminology system",
        "definition": "A reference to a code defined by a terminology system.",
        "comment": "Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information.  Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.",
        "requirements": "Allows for alternative encodings within a code system, and translations to other code systems.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "CodeableConcept.coding",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Coding"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          }
        ],
        "isModifier": false,
        "isSummary": true,
        "mapping": [
          {
            "identity": "v2",
            "map": "C*E.1-8, C*E.10-22"
          },
          {
            "identity": "rim",
            "map": "union(., ./translation)"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept.coding rdfs:subPropertyOf dt:CD.coding"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.text",
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-translatable",
            "valueBoolean": true
          }
        ],
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.text",
        "short": "Plain text representation of the concept",
        "definition": "A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user.",
        "comment": "Very often the text is the same as a displayName of one of the codings.",
        "requirements": "The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "CodeableConcept.text",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "xpath": "@value|f:*|h:div",
            "source": "http://hl7.org/fhir/StructureDefinition/Element|4.0.1"
          }
        ],
        "isModifier": false,
        "isSummary": true,
        "mapping": [
          {
            "identity": "v2",
            "map": "C*E.9. But note many systems use C*E.2 for this"
          },
          {
            "identity": "rim",
            "map": "./originalText[mediaType/code=\"text/plain\"]/data"
          },
          {
            "identity": "orim",
            "map": "fhir:CodeableConcept.text rdfs:subPropertyOf dt:CD.originalText"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.nom",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.nom",
        "short": "name",
        "definition": "name",
        "min": 1,
        "max": "1",
        "base": {
          "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.nom",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.valeur",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.valeur",
        "short": "Valeur de la topographie",
        "definition": "Valeur de la topographie",
        "min": 1,
        "max": "1",
        "base": {
          "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.valeur",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "description": "jdv-modificateur-topographique-cisis (1.2.250.1.213.1.1.5.688)"
        }
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "fr-lm-technique-imagerie",
        "path": "fr-lm-technique-imagerie",
        "short": "Logical model- FR LM Technique imagerie",
        "definition": "Entrée Technique imagerie"
      },
      {
        "id": "fr-lm-technique-imagerie.codeActe",
        "path": "fr-lm-technique-imagerie.codeActe",
        "short": "Code de l'acte d'imagerie",
        "definition": "Code de l'acte d'imagerie",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "description": "jdv-code-document-imagerie-cisis (1.2.250.1.213.1.1.5.687)"
        }
      },
      {
        "id": "fr-lm-technique-imagerie.description",
        "path": "fr-lm-technique-imagerie.description",
        "short": "Partie narrative de l'observation",
        "definition": "Partie narrative de l'observation",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Narrative"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.modaliteAcquisition",
        "path": "fr-lm-technique-imagerie.modaliteAcquisition",
        "short": "Modalité d’acquisition",
        "definition": "Modalité d’acquisition",
        "min": 1,
        "max": "*",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "description": "jdv-modalite-acquisition-cisis (1.2.250.1.213.1.1.5.618)"
        }
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite",
        "path": "fr-lm-technique-imagerie.lateralite",
        "short": "Latéralité et topographie",
        "definition": "Latéralité et topographie",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "description": "SNOMED CT (2.16.840.1.113883.6.96)"
        }
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique",
        "short": "Précision topographique",
        "definition": "Précision topographique",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.nom",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.nom",
        "short": "name",
        "definition": "name",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "fr-lm-technique-imagerie.lateralite.precisionTopographique.valeur",
        "path": "fr-lm-technique-imagerie.lateralite.precisionTopographique.valeur",
        "short": "Valeur de la topographie",
        "definition": "Valeur de la topographie",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "description": "jdv-modificateur-topographique-cisis (1.2.250.1.213.1.1.5.688)"
        }
      }
    ]
  }
}