Narratif généré : Dispositif example-mes-fr-phd-device-001
Profil: PhdDevice
identifier: IEEE 11073 System Identifier/74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address/00-1C-05-FF-E8-74
manufacturer: Nonin_Medical_Inc.
serialNumber: 501900083
modelNumber: Model 3230
type: MDC_MOC_VMS_MDS_SIMP
| SystemType | Version |
| MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter | 1 |
version
type: MDC_ID_PROD_SPEC_FW: Firmware revision
value: r2.1
version
type: MDC_ID_PROD_SPEC_SW: Software revision
value: r1.5 9.7
version
type: MDC_ID_PROD_SPEC_HW: Hardware revision
value: r1.0
version
type: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version
value: 6.0
property
type: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo
valueCode: BTLE Pulse Oximeter certified
property
type: regulation-status
valueCode: Device is Regulated
property
type: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol
valueCode: MDC_TIME_SYNC_NONE:
{
"resourceType": "Device",
"id": "example-mes-fr-phd-device-001",
"meta": {
"profile": [
"http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"
]
},
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"identifier": [
{
"type": {
"coding": [
{
"system": "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code": "SYSID"
}
]
},
"system": "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value": "74-E8-FF-FE-FF-05-1C-00"
},
{
"type": {
"coding": [
{
"system": "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code": "BTMAC"
}
]
},
"system": "http://hl7.org/fhir/sid/eui-48/bluetooth",
"value": "00-1C-05-FF-E8-74"
}
],
"manufacturer": "Nonin_Medical_Inc.",
"serialNumber": "501900083",
"modelNumber": "Model 3230",
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "65573"
}
],
"text": "MDC_MOC_VMS_MDS_SIMP"
},
"specialization": [
{
"systemType": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "528388"
}
],
"text": "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"
},
"version": "1"
}
],
"version": [
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "531976"
}
],
"text": "MDC_ID_PROD_SPEC_FW: Firmware revision"
},
"value": "r2.1"
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "531975"
}
],
"text": "MDC_ID_PROD_SPEC_SW: Software revision"
},
"value": "r1.5 9.7"
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "531974"
}
],
"text": "MDC_ID_PROD_SPEC_HW: Hardware revision"
},
"value": "r1.0"
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532352"
}
],
"text": "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value": "6.0"
}
],
"property": [
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532353"
}
],
"text": "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"
},
"valueCode": [
{
"coding": [
{
"system": "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
"code": "32772"
}
]
}
]
},
{
"type": {
"coding": [
{
"system": "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
"code": "532354.0"
}
],
"text": "regulation-status"
},
"valueCode": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0136",
"code": "N"
}
],
"text": "Device is Regulated"
}
]
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "68220"
}
],
"text": "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCode": [
{
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532224"
}
],
"text": "MDC_TIME_SYNC_NONE:"
}
]
}
]
}