FHIR IG analytics| Package | ans.document.fr.core |
| Resource Type | StructureDefinition |
| Id | StructureDefinition-fr-lm-examen-imagerie.json |
| FHIR Version | R4 |
| Source | https://interop.esante.gouv.fr/ig/document/core/0.1.0-snapshot/StructureDefinition-fr-lm-examen-imagerie.html |
| URL | https://interop.esante.gouv.fr/ig/document/core/StructureDefinition/fr-lm-examen-imagerie |
| Version | 0.1.0-snapshot |
| Status | draft |
| Date | 2026-04-15T16:11:27+00:00 |
| Name | FRLMExamenImagerie |
| Title | Modèle logique métier - FR LM Examen Imagerie |
| Realm | fr |
| Description | DICOM Examen Imagerie |
| Type | https://interop.esante.gouv.fr/ig/document/core/StructureDefinition/fr-lm-examen-imagerie |
| Kind | logical |
| ConceptMap | ||
| ans.fr.document-core#current | FRImagingStudyLMCDAFHIR | Mapping Métier/CDA/FHIR : "Examen d'imagerie" |
| ans.document.fr.core#0.1.0-snapshot | FRImagingStudyLMCDAFHIR | Mapping Métier/CDA/FHIR : "Examen d'imagerie" |
| StructureDefinition | ||
| ans.document.fr.core#0.1.0-snapshot | fr-lm-object-catalog | Modèle logique métier - FR LM Object Catalog |
| StructureDefinition | ||
| ans.document.fr.core#0.1.0-snapshot | fr-lm-serie-imagerie | Modèle logique métier - FR LM Serie imagerie |
Note: links and images are rebased to the (stated) source
Narratif généré : DéfinitionStructure fr-lm-examen-imagerie
| Nom | Drapeaux | Card. | Type | Description et contraintes |
|---|---|---|---|---|
![]() | 0..* | Base | Modèle logique métier - FR LM Examen Imagerie Les instances de ce modèle logique peuvent être la cible d'une référence | |
![]() ![]() | 1..* | Identifier | UUID instance examen | |
![]() ![]() | 1..1 | CodeableConcept | Code de l'acte | |
![]() ![]() | 0..1 | Narrative | Partie narrative de l'entrée This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |
![]() ![]() | 0..1 | dateTime | Date de l'acte | |
![]() ![]() | 1..1 | fr-lm-serie-imagerie | Serie-imagerie | |
![]() ![]() | 0..* | CodeableConcept | Objectifs de reference Description du binding: : jdv-imagerie-objectif-reference-cisis (1.2.250.1.213.1.1.5.672) | |
{
"resourceType": "StructureDefinition",
"id": "fr-lm-examen-imagerie",
"text": {
"status": "extensions",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-type-characteristics",
"valueCode": "can-be-target"
}
],
"url": "https://interop.esante.gouv.fr/ig/document/core/StructureDefinition/fr-lm-examen-imagerie",
"version": "0.1.0-snapshot",
"name": "FRLMExamenImagerie",
"title": "Modèle logique métier - FR LM Examen Imagerie",
"status": "draft",
"date": "2026-04-15T16:11:27+00:00",
"publisher": "Agence du Numérique en Santé (ANS) - 2-10 Rue d'Oradour-sur-Glane, 75015 Paris",
"contact": [
{
"name": "Agence du Numérique en Santé (ANS) - 2-10 Rue d'Oradour-sur-Glane, 75015 Paris",
"telecom": [
{
"system": "url",
"value": "https://esante.gouv.fr"
}
]
}
],
"description": "DICOM Examen Imagerie",
"jurisdiction": [
{
"coding": [
{
"system": "urn:iso:std:iso:3166",
"code": "FR",
"display": "FRANCE"
}
]
}
],
"fhirVersion": "4.0.1",
"kind": "logical",
"abstract": false,
"type": "https://interop.esante.gouv.fr/ig/document/core/StructureDefinition/fr-lm-examen-imagerie",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Base",
"derivation": "specialization",
"snapshot": {
"extension": [
{
"url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
"valueString": "4.0.1"
}
],
"element": [
{
"id": "fr-lm-examen-imagerie",
"path": "fr-lm-examen-imagerie",
"short": "Modèle logique métier - FR LM Examen Imagerie",
"definition": "DICOM Examen Imagerie",
"min": 0,
"max": "*",
"base": {
"path": "Base",
"min": 0,
"max": "*"
},
"isModifier": false
},
{
"id": "fr-lm-examen-imagerie.uuidInstanceExamen",
"path": "fr-lm-examen-imagerie.uuidInstanceExamen",
"short": "UUID instance examen",
"definition": "UUID instance examen",
"min": 1,
"max": "*",
"base": {
"path": "fr-lm-examen-imagerie.uuidInstanceExamen",
"min": 1,
"max": "*"
},
"type": [
{
"code": "Identifier"
}
]
},
{
"id": "fr-lm-examen-imagerie.codeActe",
"path": "fr-lm-examen-imagerie.codeActe",
"short": "Code de l'acte",
"definition": "Code de l'acte",
"min": 1,
"max": "1",
"base": {
"path": "fr-lm-examen-imagerie.codeActe",
"min": 1,
"max": "1"
},
"type": [
{
"code": "CodeableConcept"
}
]
},
{
"id": "fr-lm-examen-imagerie.description",
"path": "fr-lm-examen-imagerie.description",
"short": "Partie narrative de l'entrée",
"definition": "Partie narrative de l'entrée",
"min": 0,
"max": "1",
"base": {
"path": "fr-lm-examen-imagerie.description",
"min": 0,
"max": "1"
},
"type": [
{
"code": "Narrative"
}
]
},
{
"id": "fr-lm-examen-imagerie.dateActe",
"path": "fr-lm-examen-imagerie.dateActe",
"short": "Date de l'acte",
"definition": "Date de l'acte",
"min": 0,
"max": "1",
"base": {
"path": "fr-lm-examen-imagerie.dateActe",
"min": 0,
"max": "1"
},
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "fr-lm-examen-imagerie.serieImagerie",
"path": "fr-lm-examen-imagerie.serieImagerie",
"short": "Serie-imagerie",
"definition": "Serie-imagerie",
"min": 1,
"max": "1",
"base": {
"path": "fr-lm-examen-imagerie.serieImagerie",
"min": 1,
"max": "1"
},
"type": [
{
"code": "https://interop.esante.gouv.fr/ig/document/core/StructureDefinition/fr-lm-serie-imagerie"
}
]
},
{
"id": "fr-lm-examen-imagerie.objectifsReferences",
"path": "fr-lm-examen-imagerie.objectifsReferences",
"short": "Objectifs de reference",
"definition": "Objectifs de reference",
"min": 0,
"max": "*",
"base": {
"path": "fr-lm-examen-imagerie.objectifsReferences",
"min": 0,
"max": "*"
},
"type": [
{
"code": "CodeableConcept"
}
],
"binding": {
"description": "jdv-imagerie-objectif-reference-cisis (1.2.250.1.213.1.1.5.672)"
}
}
]
},
"differential": {
"element": [
{
"id": "fr-lm-examen-imagerie",
"path": "fr-lm-examen-imagerie",
"short": "Modèle logique métier - FR LM Examen Imagerie",
"definition": "DICOM Examen Imagerie"
},
{
"id": "fr-lm-examen-imagerie.uuidInstanceExamen",
"path": "fr-lm-examen-imagerie.uuidInstanceExamen",
"short": "UUID instance examen",
"definition": "UUID instance examen",
"min": 1,
"max": "*",
"type": [
{
"code": "Identifier"
}
]
},
{
"id": "fr-lm-examen-imagerie.codeActe",
"path": "fr-lm-examen-imagerie.codeActe",
"short": "Code de l'acte",
"definition": "Code de l'acte",
"min": 1,
"max": "1",
"type": [
{
"code": "CodeableConcept"
}
]
},
{
"id": "fr-lm-examen-imagerie.description",
"path": "fr-lm-examen-imagerie.description",
"short": "Partie narrative de l'entrée",
"definition": "Partie narrative de l'entrée",
"min": 0,
"max": "1",
"type": [
{
"code": "Narrative"
}
]
},
{
"id": "fr-lm-examen-imagerie.dateActe",
"path": "fr-lm-examen-imagerie.dateActe",
"short": "Date de l'acte",
"definition": "Date de l'acte",
"min": 0,
"max": "1",
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "fr-lm-examen-imagerie.serieImagerie",
"path": "fr-lm-examen-imagerie.serieImagerie",
"short": "Serie-imagerie",
"definition": "Serie-imagerie",
"min": 1,
"max": "1",
"type": [
{
"code": "https://interop.esante.gouv.fr/ig/document/core/StructureDefinition/fr-lm-serie-imagerie"
}
]
},
{
"id": "fr-lm-examen-imagerie.objectifsReferences",
"path": "fr-lm-examen-imagerie.objectifsReferences",
"short": "Objectifs de reference",
"definition": "Objectifs de reference",
"min": 0,
"max": "*",
"type": [
{
"code": "CodeableConcept"
}
],
"binding": {
"description": "jdv-imagerie-objectif-reference-cisis (1.2.250.1.213.1.1.5.672)"
}
}
]
}
}