FHIR IG analytics| Package | alticelabs.fhir.smartal.glintt |
| Resource Type | StructureDefinition |
| Id | StructureDefinition-SmartAL-Observation-Base.json |
| FHIR Version | R4 |
| Source | https://simplifier.net/resolve?scope=alticelabs.fhir.smartal.glintt@0.1.0-beta&canonical=http://alticelabs.com/fhir/StructureDefinition/SmartAL-Observation-Base |
| URL | http://alticelabs.com/fhir/StructureDefinition/SmartAL-Observation-Base |
| Status | active |
| Name | SmartALObservationBase |
| Title | SmartAL Observation (Base) |
| Description | Abstract base profile for all Observation resources sent to Glintt. Defines common constraints shared by all observation types: identifier, status, category, code, subject with Glintt viewer enrichment, effectiveDateTime, performer, interpretation, and referenceRange. Interpretation and referenceRange are automatically enriched by MHR from ObservationDefinition thresholds at creation time. They are NOT mandatory — they are only present when a matching ObservationDefinition exists. Only Observations whose code matches the whitelist are synced: - 8310-5 (Body Temperature) - 59408-5 (SpO2) - 8867-4 (Heart Rate) - 9279-1 (Respiratory Rate) - 85354-9 (Blood Pressure) - 10000-F (Gait Group — custom LOINC) - 10100-F (Cognition Group — custom LOINC) - 20000-I (ECG+PCG Valvular Assessment — custom LOINC) - 3000-G (Frailty Physical Assessment -- custom LOINC) Media and Device resources are stripped before sending to Glintt. |
| Type | Observation |
| Kind | resource |
| StructureDefinition | ||
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-BloodPressure | SmartAL Observation — Blood Pressure |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-BodyTemperature | SmartAL Observation — Body Temperature |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-CognitionGroup | SmartAL Observation — Cognition Group |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-ECGPCG | SmartAL Observation - ECG+PCG Valvular Assessment |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-Frailty | SmartAL Observation - Frailty Physical Assessment |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-GaitGroup | SmartAL Observation — Gait Group |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-HeartRate | SmartAL Observation — Heart Rate |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-RespiratoryRate | SmartAL Observation — Respiratory Rate |
| alticelabs.fhir.smartal.glintt#0.1.0-beta | SmartAL-Observation-SpO2 | SmartAL Observation — Oxygen Saturation (SpO2) |
No resources found
No narrative content found in resource
{
"resourceType": "StructureDefinition",
"id": "SmartAL-Observation-Base",
"url": "http://alticelabs.com/fhir/StructureDefinition/SmartAL-Observation-Base",
"name": "SmartALObservationBase",
"title": "SmartAL Observation (Base)",
"status": "active",
"description": "Abstract base profile for all Observation resources sent to Glintt.\nDefines common constraints shared by all observation types: identifier,\nstatus, category, code, subject with Glintt viewer enrichment,\neffectiveDateTime, performer, interpretation, and referenceRange.\n\nInterpretation and referenceRange are automatically enriched by MHR from\nObservationDefinition thresholds at creation time. They are NOT mandatory —\nthey are only present when a matching ObservationDefinition exists.\n\nOnly Observations whose code matches the whitelist are synced:\n- 8310-5 (Body Temperature)\n- 59408-5 (SpO2)\n- 8867-4 (Heart Rate)\n- 9279-1 (Respiratory Rate)\n- 85354-9 (Blood Pressure)\n- 10000-F (Gait Group — custom LOINC)\n- 10100-F (Cognition Group — custom LOINC)\n- 20000-I (ECG+PCG Valvular Assessment — custom LOINC)\n- 3000-G (Frailty Physical Assessment -- custom LOINC)\n\nMedia and Device resources are stripped before sending to Glintt.",
"fhirVersion": "4.0.1",
"kind": "resource",
"abstract": true,
"type": "Observation",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "Observation.meta.source",
"path": "Observation.meta.source",
"short": "Source system that created this resource",
"definition": "Set to 'http://alticelabs.com/fhir' by the MetaSourceInterceptor for all\nresources created via the internal backend (x-api-key). This value is used\nby the GlinttSyncInterceptor as an allowlist — only resources with this\nmeta.source are synced to Glintt. Resources created by external partners\n(e.g., P5) will have a different or absent meta.source and are excluded\nfrom Glintt sync."
},
{
"id": "Observation.identifier",
"path": "Observation.identifier",
"slicing": {
"discriminator": [
{
"type": "value",
"path": "system"
}
],
"rules": "open",
"ordered": false
},
"min": 1
},
{
"id": "Observation.identifier:altice",
"path": "Observation.identifier",
"sliceName": "altice",
"short": "Altice business identifier (UUID)",
"min": 1,
"max": "1",
"mustSupport": true
},
{
"id": "Observation.identifier:altice.system",
"path": "Observation.identifier.system",
"min": 1,
"fixedUri": "http://alticelabs.com/fhir/identifiers/observation"
},
{
"id": "Observation.identifier:altice.value",
"path": "Observation.identifier.value",
"min": 1
},
{
"id": "Observation.status",
"path": "Observation.status",
"fixedCode": "final",
"mustSupport": true
},
{
"id": "Observation.category",
"path": "Observation.category",
"short": "Classification of observation type (vital-signs, exam, etc.)",
"mustSupport": true
},
{
"id": "Observation.code",
"path": "Observation.code",
"mustSupport": true
},
{
"id": "Observation.code.coding",
"path": "Observation.code.coding",
"min": 1
},
{
"id": "Observation.subject",
"path": "Observation.subject",
"min": 1,
"type": [
{
"code": "Reference",
"targetProfile": [
"http://hl7.org/fhir/StructureDefinition/Patient"
]
}
],
"mustSupport": true
},
{
"id": "Observation.subject.reference",
"path": "Observation.subject.reference",
"min": 1
},
{
"id": "Observation.subject.identifier",
"path": "Observation.subject.identifier",
"short": "Glintt viewer identifier for subject correlation",
"definition": "When sending to Glintt, the subject reference is enriched with the Patient's Glintt viewer identifier (system: https://glintt.com/viewer)."
},
{
"id": "Observation.encounter",
"path": "Observation.encounter",
"short": "Encounter during which this observation was made"
},
{
"id": "Observation.effective[x]",
"path": "Observation.effective[x]",
"min": 1,
"type": [
{
"code": "dateTime"
}
],
"mustSupport": true
},
{
"id": "Observation.issued",
"path": "Observation.issued",
"short": "Date/time this observation was made available"
},
{
"id": "Observation.performer",
"path": "Observation.performer",
"type": [
{
"code": "Reference",
"targetProfile": [
"http://hl7.org/fhir/StructureDefinition/Practitioner"
]
}
]
},
{
"id": "Observation.interpretation",
"path": "Observation.interpretation",
"short": "MHR-enriched interpretation code",
"definition": "Interpretation code (N, L, LL, H, HH) automatically enriched by MHR from ObservationDefinition thresholds at creation time. Only present when a matching ObservationDefinition exists."
},
{
"id": "Observation.note",
"path": "Observation.note",
"short": "Clinical notes about the observation"
},
{
"id": "Observation.method",
"path": "Observation.method",
"short": "How the observation was made (e.g., manual, device)"
},
{
"id": "Observation.device",
"path": "Observation.device",
"short": "Reference to the Device that produced this observation",
"type": [
{
"code": "Reference",
"targetProfile": [
"http://hl7.org/fhir/StructureDefinition/Device"
]
}
]
},
{
"id": "Observation.referenceRange",
"path": "Observation.referenceRange",
"short": "MHR-enriched reference ranges",
"definition": "Reference ranges from matching ObservationDefinition, automatically added by MHR at creation time. Only present when a matching ObservationDefinition exists."
},
{
"id": "Observation.derivedFrom",
"path": "Observation.derivedFrom",
"short": "Related observations this observation is derived from"
}
]
}
}