| Package | DL.base |
| Resource Type | StructureDefinition |
| Id | DL_FR_PR_DocumentReference_BaseDocumentReference |
| FHIR Version | R4 |
| Source | https://simplifier.net/resolve?scope=DL.base@1.1.0&canonical=https://fhir.doctolib.com/StructureDefinition/DL_FR_PR_DocumentReference_BaseDocumentReference |
| URL | https://fhir.doctolib.com/StructureDefinition/DL_FR_PR_DocumentReference_BaseDocumentReference |
| Version | 0.1 |
| Status | active |
| Date | 2022-09-30 |
| Name | DL_FR_PR_DocumentReference_BaseDocumentReference |
| Title | DL_FR_PR_DocumentReference_BaseDocumentReference |
| Description | Doctolib's base definition of a DocumentReference. |
| Type | DocumentReference |
| Kind | resource |
No resources found
| ValueSet | |
| JDV-J02-XdsHealthcareFacilityTypeCode-CISIS | JDV_J02-XdsHealthcareFacilityTypeCode-CISIS |
| JDV-J04-XdsPracticeSettingCode-CISIS | JDV_J04-XdsPracticeSettingCode-CISIS |
| JDV-J06-XdsClassCode-CISIS | JDV_J06-XdsClassCode-CISIS |
| JDV-J07-XdsTypeCode-CISIS | JDV_J07-XdsTypeCode-CISIS |
| JDV-J10-XdsFormatCode-CISIS | JDV_J10-XdsFormatCode-CISIS |
No narrative content found in resource
{
"resourceType": "StructureDefinition",
"url": "https://fhir.doctolib.com/StructureDefinition/DL_FR_PR_DocumentReference_BaseDocumentReference",
"version": "0.1",
"name": "DL_FR_PR_DocumentReference_BaseDocumentReference",
"title": "DL_FR_PR_DocumentReference_BaseDocumentReference",
"status": "active",
"date": "2022-09-30",
"publisher": "Doctolib",
"contact": [
{
"name": "FHIR Team",
"telecom": [
{
"system": "email",
"value": "fhir-forge@doctolib.com",
"use": "work"
}
]
}
],
"description": "Doctolib's base definition of a DocumentReference.",
"fhirVersion": "4.0.1",
"kind": "resource",
"abstract": false,
"type": "DocumentReference",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/DocumentReference",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "DocumentReference.masterIdentifier",
"path": "DocumentReference.masterIdentifier",
"min": 1
},
{
"id": "DocumentReference.masterIdentifier.system",
"path": "DocumentReference.masterIdentifier.system",
"min": 1
},
{
"id": "DocumentReference.masterIdentifier.value",
"path": "DocumentReference.masterIdentifier.value",
"min": 1
},
{
"id": "DocumentReference.identifier",
"path": "DocumentReference.identifier",
"mustSupport": true
},
{
"id": "DocumentReference.identifier.system",
"path": "DocumentReference.identifier.system",
"min": 1
},
{
"id": "DocumentReference.identifier.value",
"path": "DocumentReference.identifier.value",
"min": 1
},
{
"id": "DocumentReference.status",
"path": "DocumentReference.status",
"mustSupport": true
},
{
"id": "DocumentReference.type",
"path": "DocumentReference.type",
"definition": "Les valeurs possibles pour cet élément doivent provenir d’une des terminologies de référence suivantes :\n\nTRE_A05-TypeDocComplementaireCISIS, OID : 1.2.250.1.213.1.1.4.12\nTRE_A04-TypeDocument-LOINC, OID : 2.16.840.1.113883.6.1\nTRE_A12-NomenclatureASTM, OID : ASTM Les valeurs possibles peuvent être restreintes en fonction du jeu de valeurs correspondant mis à disposition par le projet (exemple : JDV_J66-TypeCode-DMP). En l’absence de spécifications complémentaires, le jeu de valeurs JDV_J07-XdsTypeCode-CISIS peut être utilisé.",
"min": 1,
"mustSupport": true,
"binding": {
"strength": "preferred",
"description": "XDS typeCode CI-SIS",
"valueSet": "https://mos.esante.gouv.fr/NOS/JDV_J07-XdsTypeCode-CISIS/FHIR/JDV-J07-XdsTypeCode-CISIS"
}
},
{
"id": "DocumentReference.category",
"path": "DocumentReference.category",
"definition": "Les valeurs possibles pour cet élément doivent provenir d’une des terminologies de référence suivantes :\n\nTRE_A03-ClasseDocument-CISIS, OID : 1.2.250.1.213.1.1.4.1\nTRE_A10-NomenclatureURN, OID : URN Les valeurs possibles peuvent être restreintes en fonction du jeu de valeurs correspondant mis à disposition par le projet (exemple : JDV_J57-ClassCode-DMP). En l’absence de spécifications complémentaires, le jeu de valeurs JDV_J06-XdsClassCode-CISIS peut être utilisé.",
"max": "1",
"mustSupport": true,
"binding": {
"strength": "preferred",
"description": "XDS classCode CI-SIS",
"valueSet": "https://mos.esante.gouv.fr/NOS/JDV_J06-XdsClassCode-CISIS/FHIR/JDV-J06-XdsClassCode-CISIS"
}
},
{
"id": "DocumentReference.subject",
"path": "DocumentReference.subject",
"min": 1,
"mustSupport": true
},
{
"id": "DocumentReference.author",
"path": "DocumentReference.author",
"mustSupport": true
},
{
"id": "DocumentReference.relatesTo",
"path": "DocumentReference.relatesTo",
"mustSupport": true
},
{
"id": "DocumentReference.securityLabel",
"path": "DocumentReference.securityLabel",
"definition": "Les codes pour cet élément doivent provenir du ValueSet spécifié par le standard. Lorsqu’aucun code ne correspond au concept recherché, un code provenant de la terminologie de référence TRE_A07-StatusVisibiliteDocument, OID : 1.2.250.1.213.1.1.4.13 peut être utilisé (cf JDV_J110 : https://mos.esante.gouv.fr/NOS/JDV_J110-StatutVisibiliteDocument-CISIS/FHIR/JDV-J110-StatutVisibiliteDocument-CISIS).",
"min": 1,
"mustSupport": true
},
{
"id": "DocumentReference.content",
"path": "DocumentReference.content",
"max": "1",
"mustSupport": true
},
{
"id": "DocumentReference.content.attachment.contentType",
"path": "DocumentReference.content.attachment.contentType",
"min": 1
},
{
"id": "DocumentReference.content.attachment.language",
"path": "DocumentReference.content.attachment.language",
"min": 1
},
{
"id": "DocumentReference.content.attachment.data",
"path": "DocumentReference.content.attachment.data",
"max": "0"
},
{
"id": "DocumentReference.content.attachment.url",
"path": "DocumentReference.content.attachment.url",
"min": 1
},
{
"id": "DocumentReference.content.attachment.creation",
"path": "DocumentReference.content.attachment.creation",
"min": 1
},
{
"id": "DocumentReference.content.format",
"path": "DocumentReference.content.format",
"definition": "Les valeurs possibles pour cet élément doivent provenir d’une des terminologies de référence suivantes :\n\nTRE_A06-FormatCodeComplementaire, OID : 1.2.250.1.213.1.1.4.2.282\nTRE_A11-IheFormatCode, OID : 1.3.6.1.4.1.19376.1.2.3\nTRE_A09-DICOMuidRegistry, OID : 1.2.840.10008.2.6.1\nTRE_A10-NomenclatureURN, OID : URN Les valeurs possibles peuvent être restreintes en fonction du jeu de valeurs correspondant mis à disposition par le projet (exemple : JDV_J60-FormatCode-DMP). En l’absence de spécifications complémentaires, le jeu de valeurs JDV_J10-XdsFormatCode-CISIS peut être utilisé.",
"binding": {
"strength": "preferred",
"description": "XDS formatCode documents CI-SIS",
"valueSet": "https://mos.esante.gouv.fr/NOS/JDV_J10-XdsFormatCode-CISIS/FHIR/JDV-J10-XdsFormatCode-CISIS"
}
},
{
"id": "DocumentReference.context",
"path": "DocumentReference.context",
"min": 1
},
{
"id": "DocumentReference.context.encounter",
"path": "DocumentReference.context.encounter",
"mustSupport": true
},
{
"id": "DocumentReference.context.facilityType",
"path": "DocumentReference.context.facilityType",
"definition": "Les valeurs possibles pour cet élément doivent provenir d’une des terminologies de référence suivantes :\n\nTRE_A00-ProducteurDocNonPS, OID : 1.2.250.1.213.1.1.4.6 (lorsque l’auteur du document est un patient ou un équipement sous sa responsabilité)\nTRE_R02-SecteurActivite, OID : 1.2.250.1.71.4.2.4 (lorsque l’auteur du document est un professionnel ou un équipement sous sa responsabilité) Les valeurs possibles peuvent être restreintes en fonction du jeu de valeurs correspondant mis à disposition par le projet (exemple : JDV_J61-HealthcareFacilityTypeCode-DMP). En l’absence de spécifications complémentaires, le jeu de valeurs JDV_J02-XdsHealthcareFacilityTypeCode-CISIS peut être utilisé.",
"mustSupport": true,
"binding": {
"strength": "preferred",
"description": "XDS healthcareFacilityTypeCode CI-SIS",
"valueSet": "https://mos.esante.gouv.fr/NOS/JDV_J02-XdsHealthcareFacilityTypeCode-CISIS/FHIR/JDV-J02-XdsHealthcareFacilityTypeCode-CISIS"
}
},
{
"id": "DocumentReference.context.practiceSetting",
"path": "DocumentReference.context.practiceSetting",
"definition": "Les valeurs possibles pour cet élément doivent provenir d’une des terminologies de référence suivantes :\n\nTRE_A00-ProducteurDocNonPS, OID : 1.2.250.1.213.1.1.4.6 (lorsque l’auteur du document est un patient ou un équipement sous sa responsabilité)\nTRE_A01-CadreExercice, OID : 1.2.250.1.213.1.1.4.9 (lorsque l’auteur du document est un professionnel ou un équipement sous sa responsabilité) Les valeurs possibles peuvent être restreintes en fonction du jeu de valeurs correspondant mis à disposition par le projet (exemple : JDV_J62-PracticeSettingCode-DMP). En l’absence de spécifications complémentaires, le jeu de valeurs JDV_J04-XdsPracticeSettingCode-CISIS peut être utilisé.",
"mustSupport": true,
"binding": {
"strength": "preferred",
"description": "XDS practiceSettingCode CI-SIS",
"valueSet": "https://mos.esante.gouv.fr/NOS/JDV_J04-XdsPracticeSettingCode-CISIS/FHIR/JDV-J04-XdsPracticeSettingCode-CISIS"
}
}
]
}
}