Resource StructureDefinition/FHIR Server from package nictiz.fhir.nl.r4.zib2020#0.11.0-beta.1 (63 ms)
Package | nictiz.fhir.nl.r4.zib2020 |
Type | StructureDefinition |
Id | Id |
FHIR Version | R4 |
Source | https://simplifier.net/resolve?scope=nictiz.fhir.nl.r4.zib2020@0.11.0-beta.1&canonical=http://nictiz.nl/fhir/StructureDefinition/zib-FluidBalance |
Url | http://nictiz.nl/fhir/StructureDefinition/zib-FluidBalance |
Status | draft |
Name | ZibFluidBalance |
Title | zib FluidBalance |
Experimental | False |
Realm | nl |
Authority | hl7 |
Description | The total water intake and water excretion within a certain time period: a disbalance can lead to for example dehydration or overfilling. |
Purpose | This Observation resource represents the Dutch [zib ('Zorginformatiebouwsteen', i.e. Health and Care Information Model) FluidBalance v1.0.1 (2020)](https://zibs.nl/wiki/FluidBalance-v1.0.1(2020EN)). |
Copyright | Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise. |
Type | Observation |
Kind | resource |
Resources that use this resource
Resources that this resource uses
Narrative
Note: links and images are rebased to the (stated) source
No narrative is provided for definitional resources. A human-readable rendering can be found in the implementation guide(s) where this resource is used.
Source
{
"resourceType" : "StructureDefinition",
"id" : "zib-FluidBalance",
"text" : {
"status" : "empty",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">No narrative is provided for definitional resources. A human-readable rendering can be found in the implementation guide(s) where this resource is used.</div>"
},
"url" : "http://nictiz.nl/fhir/StructureDefinition/zib-FluidBalance",
"name" : "ZibFluidBalance",
"title" : "zib FluidBalance",
"status" : "draft",
"publisher" : "Nictiz",
"contact" : [
{
"name" : "Nictiz",
"telecom" : [
{
"system" : "url",
"value" : "https://www.nictiz.nl",
"use" : "work"
}
]
}
],
"description" : "The total water intake and water excretion within a certain time period: a disbalance can lead to for example dehydration or overfilling.",
"purpose" : "This Observation resource represents the Dutch [zib ('Zorginformatiebouwsteen', i.e. Health and Care Information Model) FluidBalance v1.0.1 (2020)](https://zibs.nl/wiki/FluidBalance-v1.0.1(2020EN)).",
"copyright" : "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
"fhirVersion" : "4.0.1",
"mapping" : [
{
"identity" : "zib-fluidbalance-v1.0.1-2020EN",
"uri" : "https://zibs.nl/wiki/FluidBalance-v1.0.1(2020EN)",
"name" : "zib FluidBalance-v1.0.1(2020EN)"
}
],
"kind" : "resource",
"abstract" : true,
"type" : "Observation",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Observation",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Observation",
"path" : "Observation",
"short" : "FluidBalance",
"comment" : "Several concept(s) of zib Mobility are represented using distinct Observation resources. These are grouped using the current resource and are referenced on `Observation.hasMember`:\r\n\r\n* FluidTotalIn (NL-CM:12.15.4): [zib-FluidBalance.FluidTotalIn ](http://nictiz.nl/fhir/StructureDefinition/zib-FluidBalance.FluidTotalIn)\r\n* FluidTotalOut (NL-CM:12.15.5): [zib-FluidBalance.FluidTotalOut ](http://nictiz.nl/fhir/StructureDefinition/zib-FluidBalance.FluidTotalOut)",
"alias" : [
"Vochtbalans"
],
"mapping" : [
{
"identity" : "zib-fluidbalance-v1.0.1-2020EN",
"map" : "NL-CM:12.15.1",
"comment" : "FluidBalance"
}
]
},
{
"id" : "Observation.code",
"path" : "Observation.code",
"patternCodeableConcept" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "710853006"
}
]
}
},
{
"id" : "Observation.effective[x]",
"path" : "Observation.effective[x]",
"slicing" : {
"discriminator" : [
{
"type" : "type",
"path" : "$this"
}
],
"rules" : "open"
}
},
{
"id" : "Observation.effective[x]:effectivePeriod",
"path" : "Observation.effective[x]",
"sliceName" : "effectivePeriod",
"type" : [
{
"code" : "Period"
}
]
},
{
"id" : "Observation.effective[x]:effectivePeriod.start",
"path" : "Observation.effective[x].start",
"short" : "FluidBalanceStartTime",
"definition" : "The time at which the measurement of the fluid balance was started.",
"alias" : [
"VochtbalansStarttijd"
],
"mapping" : [
{
"identity" : "zib-fluidbalance-v1.0.1-2020EN",
"map" : "NL-CM:12.15.2",
"comment" : "FluidBalanceStartTime"
}
]
},
{
"id" : "Observation.effective[x]:effectivePeriod.end",
"path" : "Observation.effective[x].end",
"short" : "FluidBalanceStopTime",
"definition" : "The time at which the measurement of the fluid balance was stopped.",
"alias" : [
"VochtbalansStoptijd"
],
"mapping" : [
{
"identity" : "zib-fluidbalance-v1.0.1-2020EN",
"map" : "NL-CM:12.15.3",
"comment" : "FluidBalanceStopTime"
}
]
},
{
"id" : "Observation.note",
"path" : "Observation.note",
"max" : "1"
},
{
"id" : "Observation.note.text",
"path" : "Observation.note.text",
"short" : "Comment",
"definition" : "Comment on the fluid balance.",
"alias" : [
"Toelichting"
],
"mapping" : [
{
"identity" : "zib-fluidbalance-v1.0.1-2020EN",
"map" : "NL-CM:12.15.6",
"comment" : "Comment"
}
]
},
{
"id" : "Observation.hasMember",
"path" : "Observation.hasMember",
"slicing" : {
"discriminator" : [
{
"type" : "profile",
"path" : "resolve()"
}
],
"rules" : "open"
}
},
{
"id" : "Observation.hasMember:fluidTotalIn",
"path" : "Observation.hasMember",
"sliceName" : "fluidTotalIn",
"definition" : "The FluidTotalIn concept (NL-CM:12.15.4) of zib FluidBalance, represented as a distinct Observation resource.",
"max" : "1",
"type" : [
{
"code" : "Reference",
"targetProfile" : [
"http://nictiz.nl/fhir/StructureDefinition/zib-FluidBalance.FluidTotalIn"
]
}
]
},
{
"id" : "Observation.hasMember:fluidTotalOut",
"path" : "Observation.hasMember",
"sliceName" : "fluidTotalOut",
"definition" : "The FluidTotalOut concept (NL-CM:12.15.5) of zib FluidBalance, represented as a distinct Observation resource.",
"max" : "1",
"type" : [
{
"code" : "Reference",
"targetProfile" : [
"http://nictiz.nl/fhir/StructureDefinition/zib-FluidBalance.FluidTotalOut"
]
}
]
}
]
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.