FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource ValueSet/FHIR Server from package ihe.pcc.mpsc#current (406 ms)

Package ihe.pcc.mpsc
Type ValueSet
Id Id
FHIR Version R4
Source https://profiles.ihe.net/PCC/mPSC/https://build.fhir.org/ig/IHE/PCC.PCS/ValueSet-IHE.PCC.VitalSigns.VS.html
Url https://profiles.ihe.net/PCC/mPSC/ValueSet/IHE.PCC.VitalSigns.VS
Version 2.0.0-draft
Status draft
Date 2024-09-03T15:04:24+00:00
Name IHE_PCC_VitalSigns_VS
Title IHE PCC Vital Signs Value Set
Experimental False
Realm uv
Authority ihe
Description The set of reccomended vital sign codes that can be used to represent vital signs in IHE's PCC profiles.

Resources that use this resource

No resources found


Resources that this resource uses

CodeSystem
http://loinc.org LOINC Code System
http://loinc.org LOINC codes used in this IG


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ValueSet IHE.PCC.VitalSigns.VS

This value set includes codes based on the following rules:

This value set excludes codes based on the following rules:


Source

{
  "resourceType" : "ValueSet",
  "id" : "IHE.PCC.VitalSigns.VS",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet IHE.PCC.VitalSigns.VS</b></p><a name=\"IHE.PCC.VitalSigns.VS\"> </a><a name=\"hcIHE.PCC.VitalSigns.VS\"> </a><a name=\"IHE.PCC.VitalSigns.VS-en-US\"> </a><p>This value set includes codes based on the following rules:</p><ul><li>Import all the codes that are contained in <a href=\"http://hl7.org/fhir/R4/valueset-observation-vitalsignresult.html\">Vital Signs</a></li><li>Include these codes as defined in <a href=\"http://loinc.org\"><code>http://loinc.org</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"https://loinc.org/3141-9/\">3141-9</a></td><td>Body weight Measured</td></tr><tr><td><a href=\"https://loinc.org/8306-3/\">8306-3</a></td><td>Body height --lying</td></tr><tr><td><a href=\"https://loinc.org/8287-5/\">8287-5</a></td><td>Head Occipital-frontal circumference by Tape measure</td></tr></table></li></ul><p>This value set excludes codes based on the following rules:</p><ul><li>Exclude these codes as defined in <a href=\"http://loinc.org\"><code>http://loinc.org</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"https://loinc.org/9843-4/\">9843-4</a></td><td>Head Occipital-frontal circumference</td></tr></table></li></ul></div>"
  },
  "url" : "https://profiles.ihe.net/PCC/mPSC/ValueSet/IHE.PCC.VitalSigns.VS",
  "version" : "2.0.0-draft",
  "name" : "IHE_PCC_VitalSigns_VS",
  "title" : "IHE PCC Vital Signs Value Set",
  "status" : "draft",
  "experimental" : false,
  "date" : "2024-09-03T15:04:24+00:00",
  "publisher" : "IHE Patient Care Coordination",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.ihe.net/ihe_domains/patient_care_coordination/"
        }
      ]
    },
    {
      "telecom" : [
        {
          "system" : "email",
          "value" : "pcc@ihe.net"
        }
      ]
    },
    {
      "name" : "IHE Patient Care Coordination",
      "telecom" : [
        {
          "system" : "email",
          "value" : "pcc@ihe.net"
        }
      ]
    }
  ],
  "description" : "The set of reccomended vital sign codes that can be used to represent vital signs in IHE's PCC profiles.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "compose" : {
    "include" : [
      {
        "valueSet" : [
          "http://hl7.org/fhir/ValueSet/observation-vitalsignresult"
        ]
      },
      {
        "system" : "http://loinc.org",
        "concept" : [
          {
            "code" : "3141-9",
            "display" : "Body weight Measured"
          },
          {
            "code" : "8306-3",
            "display" : "Body height --lying"
          },
          {
            "code" : "8287-5",
            "display" : "Head Occipital-frontal circumference by Tape measure"
          }
        ]
      }
    ],
    "exclude" : [
      {
        "system" : "http://loinc.org",
        "concept" : [
          {
            "code" : "9843-4",
            "display" : "Head Occipital-frontal circumference"
          }
        ]
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.