| Package | hl7.fhir.uv.dicom-sr |
| Resource Type | ConceptMap |
| Id | dicom-sr-measurement-report-to-fhir |
| FHIR Version | R5 |
| Source | http://hl7.org/fhir/uv/dicom-sr/https://build.fhir.org/ig/HL7/dicom-sr/ConceptMap-dicom-sr-measurement-report-to-fhir.html |
| URL | http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir |
| Version | 1.0.0 |
| Status | active |
| Date | 2025-05-01T18:03:49+00:00 |
| Name | DICOMSRMeasurementReportToFHIRMapping |
| Title | ConceptMap - DICOM SR Measurement Report to FHIR Mapping |
| Realm | uv |
| Authority | hl7 |
| Description | Mapping between DICOM® SR Measurement Report and FHIR Resources |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap dicom-sr-measurement-report-to-fhir
Mapping from DICOM-SR-Measurement-Report to Bundle
Group 1 Mapping from unspecified code system to unspecified code system
| Source Code | Relationship | Target Code | Comment |
| DICOM.Patient (Patient IE) | is equivalent to | Patient[1] | The DICOM® SR Patient IE is mapped to a FHIR Patient resource |
Group 2 Mapping from unspecified code system to unspecified code system
| Source Code | Relationship | Target Code | Comment |
| DICOM.Study (Study IE) | is equivalent to | ImagingStudy[1] | The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource |
| DICOM.Study (Study IE) | is related to | ServiceRequest[1] | The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource |
Group 3 Mapping from unspecified code system to unspecified code system
| Source Code | Relationship | Target Code | Comment |
| DICOM.Equipment (Equipment IE) | is equivalent to | Device[1] | The DICOM® SR Equipment IE may result in the creation of a new Device resource |
Group 4 Mapping from unspecified code system to unspecified code system
| Source Code | Relationship | Target Code | Comment |
| DICOM.Document (Document IE) | is narrower than | Observation[1] | Processing of the Document IE will result in the creation one or more new Observation resources |
{
"resourceType": "ConceptMap",
"id": "dicom-sr-measurement-report-to-fhir",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "ii"
}
],
"url": "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir",
"identifier": [
{
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:2.16.840.1.113883.4.642.40.39.18.7"
}
],
"version": "1.0.0",
"name": "DICOMSRMeasurementReportToFHIRMapping",
"title": "ConceptMap - DICOM SR Measurement Report to FHIR Mapping",
"status": "active",
"experimental": false,
"date": "2025-05-01T18:03:49+00:00",
"publisher": "HL7 International / Imaging Integration",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "HL7 International / Imaging Integration",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "Jonathan Whitby",
"telecom": [
{
"system": "email",
"value": "jonathan.whitby@mi.medical.canon"
},
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "Christopher Lindop",
"telecom": [
{
"system": "email",
"value": "Christopher.Lindop@ge.com"
},
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
}
],
"description": "Mapping between DICOM® SR Measurement Report and FHIR Resources",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001"
}
]
}
],
"property": [
{
"code": "references",
"type": "string"
},
{
"code": "imaging-measurement-group-map",
"type": "string"
}
],
"sourceScopeUri": "DICOM-SR-Measurement-Report",
"targetScopeUri": "Bundle",
"group": [
{
"element": [
{
"code": "DICOM.Patient",
"display": "Patient IE",
"target": [
{
"code": "Patient[1]",
"display": "Patient[1]",
"relationship": "equivalent",
"comment": "The DICOM® SR Patient IE is mapped to a FHIR Patient resource"
}
]
}
]
},
{
"element": [
{
"code": "DICOM.Study",
"display": "Study IE",
"target": [
{
"code": "ImagingStudy[1]",
"display": "ImagingStudy[1]",
"relationship": "equivalent",
"comment": "The DICOM® SR Study IE is mapped to a FHIR ImagingStudy resource"
}
]
},
{
"code": "DICOM.Study",
"display": "Study IE",
"target": [
{
"code": "ServiceRequest[1]",
"display": "ServiceRequest[1]",
"relationship": "related-to",
"comment": "The DICOM® SR Study IE is mapped to a FHIR ServiceRequest resource"
}
]
}
]
},
{
"element": [
{
"code": "DICOM.Equipment",
"display": "Equipment IE",
"target": [
{
"code": "Device[1]",
"display": "Device[1]",
"relationship": "equivalent",
"comment": "The DICOM® SR Equipment IE may result in the creation of a new Device resource"
}
]
}
]
},
{
"element": [
{
"code": "DICOM.Document",
"display": "Document IE",
"target": [
{
"code": "Observation[1]",
"display": "Observation[1]",
"relationship": "source-is-narrower-than-target",
"comment": "Processing of the Document IE will result in the creation one or more new Observation resources",
"property": [
{
"code": "imaging-measurement-group-map",
"valueString": "dicom-imaging-measurement-group-to-fhir"
},
{
"code": "references",
"valueString": "Observation.subject.reference=Patient[1].id"
},
{
"code": "references",
"valueString": "Observation.partOf.reference=ImagingStudy[1].id"
},
{
"code": "references",
"valueString": "Observation.basedOn.reference=ServiceRequest[1].id"
},
{
"code": "references",
"valueString": "Observation.device.reference=Device[1]"
}
]
}
]
}
]
}
]
}