Resource StructureDefinition/FHIR Server from package NICEProfiling.v23Q1#0.5.0 (63 ms)
Resources that use this resource
Resources that this resource uses
Source
{
"resourceType" : "StructureDefinition",
"id" : "NICE-PacemakerUsage",
"meta" : {
"lastUpdated" : "2021-12-10T12:46:36.658+00:00"
},
"url" : "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1",
"version" : "0.0.1",
"name" : "NICE-PacemakerUsage",
"title" : "NICE-PacemakerUsage",
"status" : "active",
"date" : "2021-12-10T12:43:51.6381668+00:00",
"publisher" : "NICE",
"description" : "Extension that is used to describe how the medical device is used.",
"copyright" : "CC0",
"contact" : [
{
"name" : "NICE",
"telecom" : [
{
"system" : "email",
"value" : "vragen@stichting-nice.nl"
}
]
}
],
"fhirVersion" : "3.0.2",
"kind" : "complex-type",
"abstract" : false,
"contextType" : "resource",
"context" : [
"DeviceUseStatement"
],
"type" : "Extension",
"baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "DeviceUseStatement.extension:Verified",
"path" : "DeviceUseStatement.extension",
"sliceName" : "Verified",
"short" : "Is the instance validated by a medical professional?",
"definition" : "Extension that is used to indicate whether the entire instance has been validated.\r\n\r\nEvery instance shall be validated by a hospital member / datamanager. However, this is not always feasible in case of automated submission of NICE data elements. This extensions shall be used to indicate the validation status of the instance.",
"min" : 1,
"max" : "1",
"type" : [
{
"code" : "Extension",
"profile" : "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1"
}
]
},
{
"id" : "Extension",
"path" : "Extension",
"short" : "Pacemaker usage",
"definition" : "The specific use of the external pacemaker is defined here."
},
{
"id" : "Extension.url",
"path" : "Extension.url",
"fixedUri" : "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1"
},
{
"id" : "Extension.value[x]:valueCodeableConcept",
"path" : "Extension.valueCodeableConcept",
"sliceName" : "valueCodeableConcept",
"type" : [
{
"code" : "CodeableConcept"
}
]
},
{
"id" : "Extension.value[x]:valueCodeableConcept.coding",
"path" : "Extension.valueCodeableConcept.coding",
"definition" : "The pacing of a heart via an external pacemaker (atrial or ventricular pacing) is understood to mean that a minimum 50% of the heartâs activity is initiated by the external pacemaker.\r\n\r\nThe pacemaker âstandbyâ is understood to mean that the pacemaker is physically connected to the patient, but that less than 50% of heart activity is initiated by the external pacemaker.",
"binding" : {
"strength" : "required",
"description" : "PacemakerUsage",
"valueSetUri" : "https://fhir.stichting-nice.nl/ValueSet/NICE-PacemakerUsage"
}
}
]
},
"text" : {
}
}
XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.