FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package NICEProfiling.v23Q1#0.5.0 (63 ms)

Package NICEProfiling.v23Q1
Type StructureDefinition
Id Id
FHIR Version R3
Source https://simplifier.net/resolve?scope=NICEProfiling.v23Q1@0.5.0&canonical=https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1
Url https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1
Version 0.0.1
Status active
Date 2021-12-10T12:43:51.6381668+00:00
Name NICE-PacemakerUsage
Title NICE-PacemakerUsage
Experimental False
Description Extension that is used to describe how the medical device is used.
Copyright CC0
Type Extension
Kind complex-type

Resources that use this resource

StructureDefinition
https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUse-2022Q1 NICE-PacemakerUse

Resources that this resource uses

StructureDefinition
https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1 NICE-Verified
https://fhir.stichting-nice.nl/ValueSet/NICE-PacemakerUsage NICE-PacemakerUsage


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "NICE-PacemakerUsage",
  "meta" : {
    "lastUpdated" : "2021-12-10T12:46:36.658+00:00"
  },
  "url" : "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1",
  "version" : "0.0.1",
  "name" : "NICE-PacemakerUsage",
  "title" : "NICE-PacemakerUsage",
  "status" : "active",
  "date" : "2021-12-10T12:43:51.6381668+00:00",
  "publisher" : "NICE",
  "description" : "Extension that is used to describe how the medical device is used.",
  "copyright" : "CC0",
  "contact" : [
    {
      "name" : "NICE",
      "telecom" : [
        {
          "system" : "email",
          "value" : "vragen@stichting-nice.nl"
        }
      ]
    }
  ],
  "fhirVersion" : "3.0.2",
  "kind" : "complex-type",
  "abstract" : false,
  "contextType" : "resource",
  "context" : [
    "DeviceUseStatement"
  ],
  "type" : "Extension",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Extension",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "DeviceUseStatement.extension:Verified",
        "path" : "DeviceUseStatement.extension",
        "sliceName" : "Verified",
        "short" : "Is the instance validated by a medical professional?",
        "definition" : "Extension that is used to indicate whether the entire instance has been validated.\r\n\r\nEvery instance shall be validated by a hospital member / datamanager. However, this is not always feasible in case of automated submission of NICE data elements. This extensions shall be used to indicate the validation status of the instance.",
        "min" : 1,
        "max" : "1",
        "type" : [
          {
            "code" : "Extension",
            "profile" : "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1"
          }
        ]
      },
      {
        "id" : "Extension",
        "path" : "Extension",
        "short" : "Pacemaker usage",
        "definition" : "The specific use of the external pacemaker is defined here."
      },
      {
        "id" : "Extension.url",
        "path" : "Extension.url",
        "fixedUri" : "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-PacemakerUsage-2022Q1"
      },
      {
        "id" : "Extension.value[x]:valueCodeableConcept",
        "path" : "Extension.valueCodeableConcept",
        "sliceName" : "valueCodeableConcept",
        "type" : [
          {
            "code" : "CodeableConcept"
          }
        ]
      },
      {
        "id" : "Extension.value[x]:valueCodeableConcept.coding",
        "path" : "Extension.valueCodeableConcept.coding",
        "definition" : "The pacing of a heart via an external pacemaker (atrial or ventricular pacing) is understood to mean that a minimum 50% of the heart’s activity is initiated by the external pacemaker.\r\n\r\nThe pacemaker ‘standby’ is understood to mean that the pacemaker is physically connected to the patient, but that less than 50% of heart activity is initiated by the external pacemaker.",
        "binding" : {
          "strength" : "required",
          "description" : "PacemakerUsage",
          "valueSetUri" : "https://fhir.stichting-nice.nl/ValueSet/NICE-PacemakerUsage"
        }
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.