FHIR © HL7.org  |  Server Home  |  XIG Home  |  XIG Stats  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/MA

Packagehl7.v2plus
Resource TypeStructureDefinition
IdMA
FHIR VersionR5
Sourcehttp://somewhere.org/fhir/uv/v2plus/https://build.fhir.org/ig/HL7/v2ig/StructureDefinition-MA.html
URLhttp://hl7.org/v2/StructureDefinition/MA
Version0.0.0
Statusactive
Date2025-08-11T19:32:53+00:00
NameMA
TitleHL7 v2 MA Data Type
Authorityhl7
Description*Usage Note:* The MA data type is preferred when the signal recording device outputs the waveform data by time (all signal amplitudes at time sample 1, followed by all signal amplitudes at time sample 2, followed by all signal amplitudes at time sample 3, etc.). The typical count is 32, 64, or 128 channels. At the time of this writing, the MA data type is the one used by most commercial EEG instruments, while other electrophysiological instruments (such as evoked potential instruments) may use the NA data type. The MA data type is the "natural" one for multi-channel EEG instruments since the signal acquisition process involves digitizing each channel in succession as rapidly as possible, then after a fixed interval (like 0.004 seconds) digitizing all the channels again in succession, and repeating this every 0.004 seconds as long as the recording continues. Conversion of one format to another is often not possible or desirable in near-real-time applications. For example, a long-term EEG recording may go on for 24, 48, 72, or more hours and implementations cannot wait until the recording is ended to transmit the data because physicians need to review the waveforms as the recording is in progress; this is why it only makes sense to organize the data by the MA data type which sends the data one time sample after the next. Note that, visually, the NA and MA data types are indistinguable: they both appear as a series of numeric components. They are distinguished by context, particularly when used in _OBX.5_ where the data type is specified in _OBX.3_. Use Case: Commercial EEG instruments *Example 1:* 3 channels (identical), 6 time-samples |0^0^0~1^1^1~2^2^2~3^3^3~4^4^4~5^5^5| *Example 2:* 1 channel, 11 time-samples |0~1~2~3~4~5~6~7~8~9~10|
Typehttp://hl7.org/v2/StructureDefinition/MA
Kindlogical

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
NMHL7 v2 Numeric Primitive Type
complex-data-typeHL7 v2 Complex Data Type

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: StructureDefinition MA

NameFlagsCard.TypeDescription & Constraintsdoco
.. MA 0..*V2ComplexDataTypemultiplexed array
... 1 0..1decimalSample Y From Channel 1
... 2 0..1decimalSample Y From Channel 2
... 3 0..1decimalSample Y From Channel 3
... 4 0..1decimalSample Y From Channel 4

doco Documentation for this format

Source

{
  "resourceType": "StructureDefinition",
  "id": "MA",
  "meta": {
    "profile": [
      "http://hl7.org/v2/StructureDefinition/complex-data-type-profile"
    ]
  },
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "informative",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://somewhere.org/fhir/uv/v2plus/ImplementationGuide/hl7.other.uv.v2plus"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/v2/StructureDefinition/MA",
  "version": "0.0.0",
  "name": "MA",
  "title": "HL7 v2 MA Data Type",
  "status": "active",
  "date": "2025-08-11T19:32:53+00:00",
  "publisher": "HL7 International",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://hl7.org/Special/committees/v2mgmt"
        }
      ]
    }
  ],
  "description": "*Usage Note:* The MA data type is preferred when the signal recording device outputs the waveform data by time (all signal amplitudes at time sample 1, followed by all signal amplitudes at time sample 2, followed by all signal amplitudes at time sample 3, etc.). The typical count is 32, 64, or 128 channels. At the time of this writing, the MA data type is the one used by most commercial EEG instruments, while other electrophysiological instruments (such as evoked potential instruments) may use the NA data type. The MA data type is the \"natural\" one for multi-channel EEG instruments since the signal acquisition process involves digitizing each channel in succession as rapidly as possible, then after a fixed interval (like 0.004 seconds) digitizing all the channels again in succession, and repeating this every 0.004 seconds as long as the recording continues.\n\nConversion of one format to another is often not possible or desirable in near-real-time applications. For example, a long-term EEG recording may go on for 24, 48, 72, or more hours and implementations cannot wait until the recording is ended to transmit the data because physicians need to review the waveforms as the recording is in progress; this is why it only makes sense to organize the data by the MA data type which sends the data one time sample after the next.\n\nNote that, visually, the NA and MA data types are indistinguable: they both appear as a series of numeric components. They are distinguished by context, particularly when used in _OBX.5_ where the data type is specified in _OBX.3_.\n\nUse Case: Commercial EEG instruments\n\n*Example 1:* 3 channels (identical), 6 time-samples\n\n|0^0^0~1^1^1~2^2^2~3^3^3~4^4^4~5^5^5|\n\n*Example 2:* 1 channel, 11 time-samples\n\n|0~1~2~3~4~5~6~7~8~9~10|",
  "fhirVersion": "5.0.0",
  "mapping": [
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    }
  ],
  "kind": "logical",
  "abstract": false,
  "type": "http://hl7.org/v2/StructureDefinition/MA",
  "baseDefinition": "http://hl7.org/v2/StructureDefinition/complex-data-type",
  "derivation": "specialization",
  "snapshot": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
        "valueString": "0.0.0"
      }
    ],
    "element": [
      {
        "id": "MA",
        "path": "MA",
        "short": "multiplexed array",
        "definition": "Definition: This data type is used to represent channel-multiplexed waveform data. Assuming that fields that utilize this data type repeat and that Y represents the specific repetition, the components of the repetition will reflect sample Y from each channel.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Base",
          "min": 0,
          "max": "*"
        },
        "isModifier": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "MA.1",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.1",
        "short": "Sample Y From Channel 1",
        "min": 0,
        "max": "1",
        "base": {
          "path": "MA.1",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      },
      {
        "id": "MA.2",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.2",
        "short": "Sample Y From Channel 2",
        "min": 0,
        "max": "1",
        "base": {
          "path": "MA.2",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      },
      {
        "id": "MA.3",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.3",
        "short": "Sample Y From Channel 3",
        "min": 0,
        "max": "1",
        "base": {
          "path": "MA.3",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      },
      {
        "id": "MA.4",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.4",
        "short": "Sample Y From Channel 4",
        "min": 0,
        "max": "1",
        "base": {
          "path": "MA.4",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "MA",
        "path": "MA",
        "short": "multiplexed array",
        "definition": "Definition: This data type is used to represent channel-multiplexed waveform data. Assuming that fields that utilize this data type repeat and that Y represents the specific repetition, the components of the repetition will reflect sample Y from each channel.",
        "min": 0,
        "max": "*"
      },
      {
        "id": "MA.1",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.1",
        "short": "Sample Y From Channel 1",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      },
      {
        "id": "MA.2",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.2",
        "short": "Sample Y From Channel 2",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      },
      {
        "id": "MA.3",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.3",
        "short": "Sample Y From Channel 3",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      },
      {
        "id": "MA.4",
        "extension": [
          {
            "url": "http://hl7.org/v2/StructureDefinition/optionality",
            "valueCode": "O"
          }
        ],
        "path": "MA.4",
        "short": "Sample Y From Channel 4",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "http://hl7.org/v2/StructureDefinition/NM"
          }
        ]
      }
    ]
  }
}