Package | de.gecco |
Resource Type | StructureDefinition |
Id | gecco-observation-blood-pressure |
FHIR Version | R4 |
Source | https://simplifier.net/resolve?scope=de.gecco@1.0.5&canonical=https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure |
URL | https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure |
Version | 1.0.4 |
Status | active |
Date | 2021-05-17 |
Name | BloodPressure |
Title | Blood Pressure |
Description | The blood pressure of a patient. |
Type | Observation |
Kind | resource |
No resources found
StructureDefinition | |
vital-signs-base | Vital Signs Base Profile |
No narrative content found in resource
{ "resourceType": "StructureDefinition", "id": "gecco-observation-blood-pressure", "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-category", "valueString": "Clinical.Diagnostics" }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-security-category", "valueCode": "patient" } ], "url": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure", "version": "1.0.4", "name": "BloodPressure", "title": "Blood Pressure", "status": "active", "date": "2021-05-17", "publisher": "Charité", "contact": [ { "telecom": [ { "system": "url", "value": "https://www.bihealth.org/en/research/core-facilities/interoperability/" } ] } ], "description": "The blood pressure of a patient.", "fhirVersion": "4.0.1", "mapping": [ { "identity": "workflow", "uri": "http://hl7.org/fhir/workflow", "name": "Workflow Pattern" }, { "identity": "sct-concept", "uri": "http://snomed.info/conceptdomain", "name": "SNOMED CT Concept Domain Binding" }, { "identity": "v2", "uri": "http://hl7.org/v2", "name": "HL7 v2 Mapping" }, { "identity": "rim", "uri": "http://hl7.org/v3", "name": "RIM Mapping" }, { "identity": "w5", "uri": "http://hl7.org/fhir/fivews", "name": "FiveWs Pattern Mapping" }, { "identity": "sct-attr", "uri": "http://snomed.org/attributebinding", "name": "SNOMED CT Attribute Binding" } ], "kind": "resource", "abstract": false, "type": "Observation", "baseDefinition": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/vital-signs-base", "derivation": "constraint", "differential": { "element": [ { "id": "Observation.code.coding", "path": "Observation.code.coding", "slicing": { "discriminator": [ { "type": "pattern", "path": "$this" } ], "rules": "open" }, "min": 1 }, { "id": "Observation.code.coding:loinc", "path": "Observation.code.coding", "sliceName": "loinc", "min": 1, "max": "*", "patternCoding": { "system": "http://loinc.org", "code": "85354-9" } }, { "id": "Observation.code.coding:loinc.system", "path": "Observation.code.coding.system", "min": 1 }, { "id": "Observation.code.coding:loinc.code", "path": "Observation.code.coding.code", "min": 1 }, { "id": "Observation.code.coding:snomed", "path": "Observation.code.coding", "sliceName": "snomed", "min": 0, "max": "*", "patternCoding": { "system": "http://snomed.info/sct", "code": "75367002" } }, { "id": "Observation.code.coding:snomed.system", "path": "Observation.code.coding.system", "min": 1 }, { "id": "Observation.code.coding:snomed.code", "path": "Observation.code.coding.code", "min": 1 }, { "id": "Observation.value[x]", "path": "Observation.value[x]", "max": "0" }, { "id": "Observation.component", "path": "Observation.component", "slicing": { "discriminator": [ { "type": "pattern", "path": "code" } ], "rules": "open" }, "short": "Used when reporting systolic and diastolic blood pressure.", "definition": "Used when reporting systolic and diastolic blood pressure.", "min": 2, "constraint": [ { "key": "vs-3", "severity": "error", "human": "If there is no a value a data absent reason must be present", "expression": "value.exists() or dataAbsentReason.exists()", "xpath": "f:*[starts-with(local-name(.), 'value')] or f:dataAbsentReason", "source": "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/blood-pressure" } ], "mustSupport": true }, { "id": "Observation.component:systolicBloodPressure", "path": "Observation.component", "sliceName": "systolicBloodPressure", "short": "Systolic blood pressure", "min": 1, "max": "1", "mustSupport": true }, { "id": "Observation.component:systolicBloodPressure.code", "path": "Observation.component.code", "patternCodeableConcept": { "coding": [ { "system": "http://loinc.org", "code": "8480-6" } ] }, "mustSupport": true }, { "id": "Observation.component:systolicBloodPressure.code.coding", "path": "Observation.component.code.coding", "slicing": { "discriminator": [ { "type": "pattern", "path": "$this" } ], "rules": "open" }, "min": 1 }, { "id": "Observation.component:systolicBloodPressure.code.coding:loinc", "path": "Observation.component.code.coding", "sliceName": "loinc", "min": 1, "max": "*", "patternCoding": { "system": "http://loinc.org", "code": "8480-6" } }, { "id": "Observation.component:systolicBloodPressure.code.coding:loinc.system", "path": "Observation.component.code.coding.system", "min": 1 }, { "id": "Observation.component:systolicBloodPressure.code.coding:loinc.code", "path": "Observation.component.code.coding.code", "min": 1 }, { "id": "Observation.component:systolicBloodPressure.code.coding:snomed", "path": "Observation.component.code.coding", "sliceName": "snomed", "min": 0, "max": "*", "patternCoding": { "system": "http://snomed.info/sct", "code": "271649006" } }, { "id": "Observation.component:systolicBloodPressure.code.coding:snomed.system", "path": "Observation.component.code.coding.system", "min": 1 }, { "id": "Observation.component:systolicBloodPressure.code.coding:snomed.code", "path": "Observation.component.code.coding.code", "min": 1 }, { "id": "Observation.component:systolicBloodPressure.value[x]", "path": "Observation.component.value[x]", "slicing": { "discriminator": [ { "type": "type", "path": "$this" } ], "rules": "open" }, "type": [ { "code": "Quantity" } ], "mustSupport": true }, { "id": "Observation.component:systolicBloodPressure.valueQuantity", "path": "Observation.component.valueQuantity", "short": "Systolic blood pressure value", "min": 0, "max": "1", "mustSupport": true }, { "id": "Observation.component:systolicBloodPressure.valueQuantity.value", "path": "Observation.component.valueQuantity.value", "min": 1 }, { "id": "Observation.component:systolicBloodPressure.valueQuantity.unit", "path": "Observation.component.valueQuantity.unit", "min": 1 }, { "id": "Observation.component:systolicBloodPressure.valueQuantity.system", "path": "Observation.component.valueQuantity.system", "min": 1, "patternUri": "http://unitsofmeasure.org" }, { "id": "Observation.component:systolicBloodPressure.valueQuantity.code", "path": "Observation.component.valueQuantity.code", "min": 1, "patternCode": "mm[Hg]" }, { "id": "Observation.component:diastolicBloodPressure", "path": "Observation.component", "sliceName": "diastolicBloodPressure", "short": "Diastolic blood pressure", "min": 1, "max": "1", "mustSupport": true }, { "id": "Observation.component:diastolicBloodPressure.code", "path": "Observation.component.code", "patternCodeableConcept": { "coding": [ { "system": "http://loinc.org", "code": "8462-4" } ] }, "mustSupport": true }, { "id": "Observation.component:diastolicBloodPressure.code.coding", "path": "Observation.component.code.coding", "slicing": { "discriminator": [ { "type": "pattern", "path": "$this" } ], "rules": "open" }, "min": 1 }, { "id": "Observation.component:diastolicBloodPressure.code.coding:loinc", "path": "Observation.component.code.coding", "sliceName": "loinc", "min": 1, "max": "*", "patternCoding": { "system": "http://loinc.org", "code": "8462-4" } }, { "id": "Observation.component:diastolicBloodPressure.code.coding:loinc.system", "path": "Observation.component.code.coding.system", "min": 1 }, { "id": "Observation.component:diastolicBloodPressure.code.coding:loinc.code", "path": "Observation.component.code.coding.code", "min": 1 }, { "id": "Observation.component:diastolicBloodPressure.code.coding:snomed", "path": "Observation.component.code.coding", "sliceName": "snomed", "min": 0, "max": "*", "patternCoding": { "system": "http://snomed.info/sct", "code": "271650006" } }, { "id": "Observation.component:diastolicBloodPressure.code.coding:snomed.system", "path": "Observation.component.code.coding.system", "min": 1 }, { "id": "Observation.component:diastolicBloodPressure.code.coding:snomed.code", "path": "Observation.component.code.coding.code", "min": 1 }, { "id": "Observation.component:diastolicBloodPressure.value[x]", "path": "Observation.component.value[x]", "slicing": { "discriminator": [ { "type": "type", "path": "$this" } ], "rules": "open" }, "type": [ { "code": "Quantity" } ], "mustSupport": true }, { "id": "Observation.component:diastolicBloodPressure.valueQuantity", "path": "Observation.component.valueQuantity", "short": "Diastolic blood pressure value", "min": 0, "max": "1", "mustSupport": true }, { "id": "Observation.component:diastolicBloodPressure.valueQuantity.value", "path": "Observation.component.valueQuantity.value", "min": 1 }, { "id": "Observation.component:diastolicBloodPressure.valueQuantity.unit", "path": "Observation.component.valueQuantity.unit", "min": 1 }, { "id": "Observation.component:diastolicBloodPressure.valueQuantity.system", "path": "Observation.component.valueQuantity.system", "min": 1, "patternUri": "http://unitsofmeasure.org" }, { "id": "Observation.component:diastolicBloodPressure.valueQuantity.code", "path": "Observation.component.valueQuantity.code", "min": 1, "patternCode": "mm[Hg]" } ] } }